Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy

被引:33
|
作者
Cheung, Joo Yeon [1 ]
Kim, Yookyung [1 ]
Shim, Sung Shine [1 ]
Lim, Soo Mee [1 ]
机构
[1] Ewha Womans Univ, Dept Radiol, Sch Med, Seoul 158710, South Korea
关键词
Biopsy; Cone beam CT; Fluoroscopy; Lung; SOLITARY PULMONARY NODULES; ASPIRATION BIOPSY; DIAGNOSTIC-ACCURACY; LUNG NODULES; COMPUTED-TOMOGRAPHY; GUIDANCE; LESIONS; PNEUMOTHORAX; SAFETY; MASSES;
D O I
10.3348/kjr.2011.12.1.89
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB). Materials and Methods: We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose. Results: The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep (>= 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%; group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 +/- 4.0 minutes, 157.1 +/- 76.5 mGy) than in group B (9.0 +/- 3.5 minutes, 21.9 +/- 15.2 mGy) (p < 0.05). Conclusion: Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions (>= 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 50 条
  • [41] CT fluoroscopy guided transthoracic core needle biopsy of pulmonary lesions: A study of 69 lesions
    Bladt, O
    Verschakelen, J
    De Wever, W
    LUNG CANCER, 2005, 49 : S208 - S208
  • [42] CT-guided transthoracic needle biopsy: A comparison between automated biopsy gun and fine needle aspiration
    Arakawa, H
    Nakajima, Y
    Kurihara, Y
    Niimi, H
    Ishikawa, T
    CLINICAL RADIOLOGY, 1996, 51 (07) : 503 - 506
  • [43] CT fluoroscopy-guided perctaneous needle biopsy of pulmonary lesions: Correlation between CT images and histological appearance
    Awaya, H
    Nagaoka, S
    Tanabe, M
    Matsumoto, T
    CHEST, 2004, 126 (04) : 853S - 853S
  • [44] Percutaneous CT-guided biopsy: Improved confirmation of sampling site and needle positioning using a multistep technique at CT fluoroscopy
    Goldberg, SN
    Keogan, MT
    Raptopoulos, V
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (02) : 264 - 266
  • [45] Pitfalls in CT-guided transthoracic needle biopsy of pulmonary nodules
    Yankelevitz, DF
    Davis, SD
    Chiarella, DA
    Henschke, CI
    RADIOGRAPHICS, 1996, 16 (05) : 1073 - 1084
  • [46] CT-guided transthoracic needle biopsy: How we do it☆
    Balbi, Maurizio
    Righi, Luisella
    Culasso, Noemi Cristina
    Bignoli, Marta
    Senkeev, Rouslan
    Garello, Ludwig Federico
    Carota, Damiano
    Sobrero, Simona
    Novello, Silvia
    Veltri, Andrea
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 184
  • [47] CT-guided transthoracic needle biopsy in the diagnosis of chest tumours
    Cattelani, L
    Campodonico, F
    Rusca, M
    Solli, P
    Carbognani, P
    Spaggiari, L
    DalCorso, HM
    JOURNAL OF CARDIOVASCULAR SURGERY, 1997, 38 (05): : 539 - 542
  • [48] Feasibility of Vacuum-Assisted Breast Cone-Beam CT-Guided Biopsy and Comparison With Prone Stereotactic Biopsy
    Wienbeck, Susanne
    Lotz, Joachim
    Fischer, Uwe
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (05) : 1154 - 1162
  • [49] Target visibility enhancement for C-arm cone beam CT-fluoroscopy-guided hepatic needle placement: implementation and accuracy evaluation
    Wang, Mengjiao
    Ding, Hui
    Wang, Xiaodong
    Wang, Guangzhi
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (03) : 263 - 273
  • [50] Target visibility enhancement for C-arm cone beam CT-fluoroscopy-guided hepatic needle placement: implementation and accuracy evaluation
    Mengjiao Wang
    Hui Ding
    Xiaodong Wang
    Guangzhi Wang
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 263 - 273