Use of Ablation Index-Guided Ablation Results in High Rates of Durable Pulmonary Vein Isolation and Freedom From Arrhythmia in Persistent Atrial Fibrillation Patients The PRAISE Study Results

被引:214
|
作者
Hussein, Ahmed [1 ]
Das, Moloy [2 ]
Riva, Stefania [3 ]
Morgan, Maureen [1 ]
Ronayne, Christina [1 ]
Sahni, Ankita [1 ]
Shaw, Matthew [1 ]
Todd, Derick [1 ]
Hall, Mark [1 ]
Modi, Simon [1 ]
Natale, Andrea [4 ]
Dello Russo, Antonio [3 ]
Snowdon, Richard [1 ]
Gupta, Dhiraj [1 ]
机构
[1] Liverpool Heart & Chest Hosp, Inst Cardiovasc Med & Sci, Dept Cardiol, Thomas Dr, Liverpool L14 3PE, Merseyside, England
[2] Freeman Rd Hosp, Dept Cardiol, Newcastle Upon Tyne, Tyne & Wear, England
[3] Ctr Cardiol Monzino, Milan, Italy
[4] St Davids Med Ctr, Austin, TX USA
来源
关键词
ablation index; atrial fibrillation; body mass index; catheter ablation; pulmonary veins; CONTACT FORCE; CATHETER ABLATION; RECONNECTION;
D O I
10.1161/CIRCEP.118.006576
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Catheter ablation for persistent atrial fibrillation (AF) is associated with less favorable outcomes than for paroxysmal AF. Substrate modification is often added to pulmonary vein isolation (PVI) to try to improve success rates. Recent studies have shown improved clinical outcomes with use of regional ablation index (AI) targets for PVI. We hypothesized that prospective use of AI-guided PVI in persistent AF patients would result in a low rate of PV reconnection at repeat electrophysiology study and that a high success rate can be achieved with durable PVI alone. Methods: Forty consecutive patients with persistent AF underwent AI-guided PVI with target values of 550 for anterior and 400 for posterior left atrial regions, followed by a protocol-mandated repeat procedure after 2 months. Patients were monitored for atrial tachyarrhythmia recurrence via daily plus symptom-initiated ECG recordings for 12 months. Recurrence was defined as >= 30 seconds of any atrial tachyarrhythmia after a 3-month blanking period. Results: PV reconnection was seen at repeat electrophysiology study in 22% of patients, affecting 7% of PVs. Ablation on the intervenous carina was required in 44% patients to achieve durable PVI. Atrial tachyarrhythmia recurrence was documented in 8 (20%) patients, only one of whom had PV reconnection at repeat study. At 12 months, 38/40 (95%) patients were in sinus rhythm, with 4 (10%) patients having started antiarrhythmic drugs. Higher body mass index and excess alcohol consumption were the only significant factors associated with atrial tachyarrhythmia recurrence. Conclusions: Use of AI targets results in a high level of durable PVI. A good clinical outcome can be achieved in the great majority of persistent AF patients with AI-guided PVI alone.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Efficacy of ablation index-guided pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Jiang, Ruhong
    Chen, Minglong
    Fan, Jie
    Yi, Fu
    Tang, Anli
    Liu, Xingpeng
    Zhu, Wenqing
    Liu, Shaowen
    Huang, Xiaobo
    Liu, Qiang
    Ju, Weizhu
    Zhang, Xi
    Li, Jie
    He, Jiangui
    Shi, Liang
    Zhou, Genqing
    Wang, Yuegang
    Fu, Guosheng
    Jiang, Chenyang
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (10): : 1186 - 1193
  • [2] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Kobayashi, Shuhei
    Fukaya, Hidehira
    Oikawa, Jun
    Saito, Daiki
    Sato, Tetsuro
    Matsuura, Gen
    Arakawa, Yuki
    Shirakawa, Yuki
    Nishinarita, Ryo
    Horiguchi, Ai
    Ishizue, Naruya
    Kishihara, Jun
    Niwano, Shinichi
    Ako, Junya
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 123 - 131
  • [3] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Shuhei Kobayashi
    Hidehira Fukaya
    Jun Oikawa
    Daiki Saito
    Tetsuro Sato
    Gen Matsuura
    Yuki Arakawa
    Yuki Shirakawa
    Ryo Nishinarita
    Ai Horiguchi
    Naruya Ishizue
    Jun Kishihara
    Shinichi Niwano
    Junya Ako
    Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 123 - 131
  • [4] Ablation index-guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study
    Chen, Shaojie
    Schmidt, Boris
    Bordignon, Stefano
    Urbanek, Lukas
    Tohoku, Shota
    Bologna, Fabrizio
    Angelkov, Lazar
    Garvanski, Iskren
    Tsianakas, Nikolaos
    Konstantinou, Athanasios
    Trolese, Luca
    Weise, Felix
    Perrotta, Laura
    Chun, K. R. Julian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (12) : 2724 - 2731
  • [5] Ablation Index-guided Pulmonary Vein Isolation Improve Performance and Safety of Treatment of Atrial Fibrillation
    Zou, Cao
    Sun, Si-Jia
    Hu, Ming-Sheng
    CIRCULATION, 2021, 144
  • [6] Ablation index-guided ablation versus second-generation cryoballoon for first pulmonary vein isolation in atrial fibrillation
    Felix-Oliveira, A.
    Carmo, J.
    Carmo, P.
    Cavaco, D.
    Fontes, A.
    Rodrigues, G.
    Matos, D.
    Moscoso Costa, F.
    Bello Morgado, F.
    Adragao, P.
    Carvalho, S.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1212 - 1212
  • [7] Extensive Posterior Wall Isolation on Top of Pulmonary Vein Isolation Guided by Ablation Index in Persistent Atrial Fibrillation Ablation
    Sabatino, Francesco
    Oriente, Domenico
    Fortunato, Fabrizio
    Cascino, Antonio
    Ferrara, Giuliano
    Sgarito, Giuseppe
    Conti, Sergio
    LIFE-BASEL, 2023, 13 (03):
  • [8] Durable pulmonary vein isolation but not complex substrate ablation determines the type of arrhythmia recurrence after persistent atrial fibrillation ablation
    Raphael Spittler
    Fabian Bahlke
    Boris Alexander Hoffmann
    Alexandra Marx
    Hanke Mollnau
    Blanca Quesada-Ocete
    Torsten Konrad
    Thomas Rostock
    Journal of Interventional Cardiac Electrophysiology, 2022, 64 : 417 - 426
  • [9] Durable pulmonary vein isolation but not complex substrate ablation determines the type of arrhythmia recurrence after persistent atrial fibrillation ablation
    Spittler, Raphael
    Bahlke, Fabian
    Hoffmann, Boris Alexander
    Marx, Alexandra
    Mollnau, Hanke
    Quesada-Ocete, Blanca
    Konrad, Torsten
    Rostock, Thomas
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 64 (02) : 417 - 426
  • [10] Optimal Inter-Lesion Distance in Ablation Index-Guided Pulmonary Vein Isolation for Atrial Fibrillation
    Kobayashi, Shuhei
    Fukaya, Hidehira
    Niwano, Shinichi
    Sato, Tetsuro
    Matsuura, Gen
    Arakawa, Yuki
    Shirakawa, Yuki
    Horiguchi, Ai
    Ishizue, Naruya
    Nishinarita, Ryo
    Oikawa, Jun
    Kishihara, Jun
    Ako, Junya
    CIRCULATION, 2019, 140