Use of Ablation Index-Guided Ablation Results in High Rates of Durable Pulmonary Vein Isolation and Freedom From Arrhythmia in Persistent Atrial Fibrillation Patients The PRAISE Study Results

被引:214
|
作者
Hussein, Ahmed [1 ]
Das, Moloy [2 ]
Riva, Stefania [3 ]
Morgan, Maureen [1 ]
Ronayne, Christina [1 ]
Sahni, Ankita [1 ]
Shaw, Matthew [1 ]
Todd, Derick [1 ]
Hall, Mark [1 ]
Modi, Simon [1 ]
Natale, Andrea [4 ]
Dello Russo, Antonio [3 ]
Snowdon, Richard [1 ]
Gupta, Dhiraj [1 ]
机构
[1] Liverpool Heart & Chest Hosp, Inst Cardiovasc Med & Sci, Dept Cardiol, Thomas Dr, Liverpool L14 3PE, Merseyside, England
[2] Freeman Rd Hosp, Dept Cardiol, Newcastle Upon Tyne, Tyne & Wear, England
[3] Ctr Cardiol Monzino, Milan, Italy
[4] St Davids Med Ctr, Austin, TX USA
来源
关键词
ablation index; atrial fibrillation; body mass index; catheter ablation; pulmonary veins; CONTACT FORCE; CATHETER ABLATION; RECONNECTION;
D O I
10.1161/CIRCEP.118.006576
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Catheter ablation for persistent atrial fibrillation (AF) is associated with less favorable outcomes than for paroxysmal AF. Substrate modification is often added to pulmonary vein isolation (PVI) to try to improve success rates. Recent studies have shown improved clinical outcomes with use of regional ablation index (AI) targets for PVI. We hypothesized that prospective use of AI-guided PVI in persistent AF patients would result in a low rate of PV reconnection at repeat electrophysiology study and that a high success rate can be achieved with durable PVI alone. Methods: Forty consecutive patients with persistent AF underwent AI-guided PVI with target values of 550 for anterior and 400 for posterior left atrial regions, followed by a protocol-mandated repeat procedure after 2 months. Patients were monitored for atrial tachyarrhythmia recurrence via daily plus symptom-initiated ECG recordings for 12 months. Recurrence was defined as >= 30 seconds of any atrial tachyarrhythmia after a 3-month blanking period. Results: PV reconnection was seen at repeat electrophysiology study in 22% of patients, affecting 7% of PVs. Ablation on the intervenous carina was required in 44% patients to achieve durable PVI. Atrial tachyarrhythmia recurrence was documented in 8 (20%) patients, only one of whom had PV reconnection at repeat study. At 12 months, 38/40 (95%) patients were in sinus rhythm, with 4 (10%) patients having started antiarrhythmic drugs. Higher body mass index and excess alcohol consumption were the only significant factors associated with atrial tachyarrhythmia recurrence. Conclusions: Use of AI targets results in a high level of durable PVI. A good clinical outcome can be achieved in the great majority of persistent AF patients with AI-guided PVI alone.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Repeat catheter ablation in patients with atrial arrhythmia recurrence despite durable pulmonary vein isolation
    Sciacca, Vanessa
    Fink, Thomas
    Eitel, Charlotte
    Heeger, Christian-Hendrik
    Sano, Makoto
    Reil, Jan-Christian
    Eitel, Ingo
    Kuck, Karl-Heinz
    Vogler, Julia
    Tilz, Roland R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (09) : 2003 - 2012
  • [22] Pulmonary Vein Isolation Followed by Biatrial Ablation of Rotational Activity in Patients with Persistent Atrial Fibrillation: Results of the Cryo-Vest Study
    Weipert, Kay Felix
    Hutter, Julie
    Kuniss, Malte
    Kahle, Patrick
    Yogarajah, Joerg
    Hain, Andreas
    Sperzel, Johannes
    Berkowitsch, Alexander
    Hamm, Christian W.
    Neumann, Thomas
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (04)
  • [23] High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation-markers of arrhythmia recurrence?
    Sousa, Pedro A.
    Puga, Luis
    Barra, Sergio
    Campos, Diana
    Antonio, Natalia
    Elvas, Luis
    Goncalves, Lino
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (01) : 115 - 121
  • [24] Impact of local left atrial wall thickness on the incidence of acute pulmonary vein reconnection after Ablation Index-guided atrial fibrillation ablation
    Mulder, Mark J.
    Kemme, Michiel J. B.
    Hagen, Amaya M. D.
    Hopman, Luuk H. G. A.
    van de Ven, Peter M.
    Hauer, Herbert A.
    Tahapary, Giovanni J. M.
    Gotte, Marco J. W.
    van Rossum, Albert C.
    Allaart, Cornelis P.
    IJC HEART & VASCULATURE, 2020, 29
  • [25] Hybrid ablation in patients with persistent atrial fibrillation or prior failed pulmonary vein isolation
    Al-Jazairi, M. I. H.
    Klinkenberg, T. J.
    Rienstra, M.
    Van Gelder, I. C.
    Mariani, M.
    Blaauw, Y.
    EUROPEAN HEART JOURNAL, 2017, 38 : 11 - 11
  • [26] One-year outcome and durability of pulmonary vein isolation after prospective use of ablation index for catheter ablation in patients with persistent atrial fibrillation
    Reinsch, Nico
    Fueting, Anna
    Buchholz, Jochen
    Ruprecht, Ute
    Holzendorf, Volker
    Buschmeier, Felix
    Kaelsch, Hagen
    Neven, Kars
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 143 - 151
  • [27] One-year outcome and durability of pulmonary vein isolation after prospective use of ablation index for catheter ablation in patients with persistent atrial fibrillation
    Nico Reinsch
    Anna Füting
    Jochen Buchholz
    Ute Ruprecht
    Volker Holzendorf
    Felix Buschmeier
    Hagen Kälsch
    Kars Neven
    Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 143 - 151
  • [28] High-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation
    Okamatsu, Hideharu
    Koyama, Junjiro
    Sakai, Yoshirou
    Negishi, Koudai
    Hayashi, Katsuhide
    Tsurugi, Takuo
    Tanaka, Yasuaki
    Nakao, Koichi
    Sakamoto, Tomohiro
    Okumura, Ken
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (12) : 2751 - 2758
  • [29] Repeat pulmonary vein isolation in patients with atrial fibrillation: low ablation index is associated with increased risk of recurrent arrhythmia
    Kristiansen, Steen B.
    Shafaq, Ajmal
    Tofig, Bawer J.
    Gerdes, Christian
    Jensen, Henrik K.
    Kristensen, Jens
    Parner, Erik T.
    Lukac, Peter
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2021, 55 (01) : 29 - 34
  • [30] Predictors of pulmonary vein non-reconnection in the second procedure after ablation index-guided pulmonary vein isolation for atrial fibrillation and its impact on the outcome
    Okamatsu, Hideharu
    Okumura, Ken
    Onishi, Fumitaka
    Yoshimura, Akino
    Negishi, Kodai
    Tanaka, Yasuaki
    Tsurugi, Takuo
    Nakao, Koichi
    Sakamoto, Tomohiro
    Koyama, Junjiro