Efficacy of ablation index-guided pulmonary vein isolation in patients with paroxysmal atrial fibrillation

被引:4
|
作者
Jiang, Ruhong [1 ]
Chen, Minglong [2 ]
Fan, Jie [3 ]
Yi, Fu [4 ]
Tang, Anli [5 ]
Liu, Xingpeng [6 ]
Zhu, Wenqing [7 ]
Liu, Shaowen [8 ]
Huang, Xiaobo [9 ]
Liu, Qiang [1 ]
Ju, Weizhu [2 ]
Zhang, Xi [3 ]
Li, Jie [4 ]
He, Jiangui [5 ]
Shi, Liang [6 ]
Zhou, Genqing [8 ]
Wang, Yuegang [9 ]
Fu, Guosheng [1 ]
Jiang, Chenyang [1 ]
机构
[1] Zhejiang Univ, Sir Run Run Shaw Hosp, Sch Med, Hangzhou, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 1, Nanjing, Peoples R China
[3] First Peoples Hosp Yunnan Prov, Kunming, Yunnan, Peoples R China
[4] Air Force Med Univ, Xijing Hosp, Xian, Peoples R China
[5] Sun Yat Sen Univ, Affiliated Hosp 1, Guangzhou, Peoples R China
[6] Capital Med Univ, Beijing Chaoyang Hosp, Beijing, Peoples R China
[7] Fudan Univ, Zhongshan Hosp, Shanghai, Peoples R China
[8] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Sch Med, Shanghai, Peoples R China
[9] Southern Med Univ, Nanfang Hosp, Guangzhou, Peoples R China
来源
关键词
ablation index; atrial fibrillation; catheter ablation; contact force; radiofrequency ablation; CONTACT FORCE; CATHETER; OUTCOMES; TARGETS; TRIAL;
D O I
10.1111/pace.14578
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Ablation index (AI) is a novel technology of ablation lesion quality to help improve homogeneity of lesion size and continuity. In this study, we aim to evaluate whether AI-guided PVI improves clinical outcomes compared to CF-guided PVI in patients with paroxysmal AF (PAF). Methods Patients undergoing first-time radiofrequency ablation for PAF were randomized in a 2:1 ratio to two groups: AI-guided PVI and CF-guided PVI. In the AI group, AI >= 500 was recommended at the anterior/superior/inferior walls, 350-400 at the posterior wall, and inter-lesion distance <= 4 mm. The primary endpoint is the freedom from atrial arrhythmia recurrence during 12 months follow-up, without antiarrhythmic drug therapy (ADT). The key secondary endpoints include intra-procedural efficiency and peri-procedural complications. Results Two hundred twenty five patients were randomized (AI group [n = 149] and CF group [n = 76]). First-pass isolation rate in AI group was significantly higher than that in CF group (58.3% vs. 43.4%, p = .035). After a median follow-up of 12.2 months, 154/225 (68.4%) of patients were free from atrial arrhythmia recurrence without ADT, which was higher in AI group compared with CF group, but without significant difference (71.1% vs. 63.2%, p = .253). The incidence of peri-procedural complications is low and without difference between two groups. Conclusions AI-guided ablation provided higher acute efficacy than CF-guided ablation in PV isolation for patients with paroxysmal AF. The long-term success rate in AI group was higher than CF group, but did not reach statistical significance.
引用
收藏
页码:1186 / 1193
页数:8
相关论文
共 50 条
  • [1] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Shuhei Kobayashi
    Hidehira Fukaya
    Jun Oikawa
    Daiki Saito
    Tetsuro Sato
    Gen Matsuura
    Yuki Arakawa
    Yuki Shirakawa
    Ryo Nishinarita
    Ai Horiguchi
    Naruya Ishizue
    Jun Kishihara
    Shinichi Niwano
    Junya Ako
    [J]. Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 123 - 131
  • [2] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Kobayashi, Shuhei
    Fukaya, Hidehira
    Oikawa, Jun
    Saito, Daiki
    Sato, Tetsuro
    Matsuura, Gen
    Arakawa, Yuki
    Shirakawa, Yuki
    Nishinarita, Ryo
    Horiguchi, Ai
    Ishizue, Naruya
    Kishihara, Jun
    Niwano, Shinichi
    Ako, Junya
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 123 - 131
  • [3] Ablation Index-guided Pulmonary Vein Isolation Improve Performance and Safety of Treatment of Atrial Fibrillation
    Zou, Cao
    Sun, Si-Jia
    Hu, Ming-Sheng
    [J]. CIRCULATION, 2021, 144
  • [4] Efficacy of pulmonary vein isolation by cryoballon ablation in patients with paroxysmal atrial fibrillation
    Klein, Gunnar
    Oswald, Hanno
    Gardiwal, Ajmal
    Luesebrink, Ulrich
    Lissel, Christoph
    Yu, Hong
    Drexler, Helmut
    [J]. HEART RHYTHM, 2008, 5 (06) : 802 - 806
  • [5] Optimal Inter-Lesion Distance in Ablation Index-Guided Pulmonary Vein Isolation for Atrial Fibrillation
    Kobayashi, Shuhei
    Fukaya, Hidehira
    Niwano, Shinichi
    Sato, Tetsuro
    Matsuura, Gen
    Arakawa, Yuki
    Shirakawa, Yuki
    Horiguchi, Ai
    Ishizue, Naruya
    Nishinarita, Ryo
    Oikawa, Jun
    Kishihara, Jun
    Ako, Junya
    [J]. CIRCULATION, 2019, 140
  • [6] Comparison of advanced generation cryoballoon ablation and ablation index-guided pulmonary vein isolation with non-pulmonary vein trigger induction test and additional ablation in paroxysmal atrial fibrillation
    Egami, Yasuyuki
    Nishino, Masami
    Nohara, Hiroaki
    Kawanami, Shodai
    Sugae, Hiroki
    Ukita, Kohei
    Kawamura, Akito
    Nakamura, Hitoshi
    Yasumoto, Koji
    Tsuda, Masaki
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Tanouchi, Jun
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (07) : 1571 - 1580
  • [7] Comparison of advanced generation cryoballoon ablation and ablation index-guided pulmonary vein isolation with non-pulmonary vein trigger induction test and additional ablation in paroxysmal atrial fibrillation
    Yasuyuki Egami
    Masami Nishino
    Hiroaki Nohara
    Shodai Kawanami
    Hiroki Sugae
    Kohei Ukita
    Akito Kawamura
    Hitoshi Nakamura
    Koji Yasumoto
    Masaki Tsuda
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masamichi Yano
    Jun Tanouchi
    [J]. Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1571 - 1580
  • [8] The efficacy of inducibility and circumferential ablation with pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Chang, Shih-Lin
    Tai, Ching-Tai
    Lin, Yenn-Jiang
    Wongcharoen, Wanwarang
    Lo, Li-Wei
    Tuan, Ta-Chuan
    Udyavar, Ameya R.
    Chang, Sheng-Hsiung
    Tsao, Hsuan-Ming
    Hsieh, Ming-Hsiung
    Hu, Yu-Feng
    Chen, Yi-Jen
    Chen, Shih-Ann
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (06) : 607 - 611
  • [9] Ablation index-guided ablation versus second-generation cryoballoon for first pulmonary vein isolation in atrial fibrillation
    Felix-Oliveira, A.
    Carmo, J.
    Carmo, P.
    Cavaco, D.
    Fontes, A.
    Rodrigues, G.
    Matos, D.
    Moscoso Costa, F.
    Bello Morgado, F.
    Adragao, P.
    Carvalho, S.
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 : 1212 - 1212
  • [10] Cryoballoon ablation for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kuehne, Michael
    Schaer, Beat
    Ammann, Peter
    Suter, Yves
    Osswald, Stefan
    Sticherling, Christian
    [J]. SWISS MEDICAL WEEKLY, 2010, 140 (15-16) : 214 - 221