Pattern of isthmus conduction recovery using open cooled and solid large-tip catheters for radiofrequency ablation of typical atrial flutter

被引:30
|
作者
Ventura, R [1 ]
Klemm, H [1 ]
Lutomsky, B [1 ]
Demir, C [1 ]
Rostock, T [1 ]
Weiss, C [1 ]
Meinertz, T [1 ]
Willems, S [1 ]
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Cardiol, D-20246 Hamburg, Germany
关键词
isthmus recovery atrial flutter ablation;
D O I
10.1046/j.1540-8167.2004.04125.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cooled Versus Large-Tip Catheters for Flutter Ablation. Introduction: Open cooled-tip and solid 8-mm-tip catheters have demonstrated safety and effectiveness for radiofrequency current (RFC) ablation of typical atrial flutter (AFL). However, data from prospective and randomized studies in this setting are lacking. Methods and Results: One hundred thirty consecutive patients (104 men; 61 +/- 11 years) with AFL were randomized to undergo RFC catheter ablation either using a solid 8-mm-tip catheter (group A, 65degreesC, 70 W, 60 s) or an open irrigated-tip catheter (group B, 65degreesC, 50 W, 60 s, 17 mL/min flow). Endpoint was bidirectional conduction isthmus block. In cases of repeated (two times) transient isthmus block, the catheter was changed (crossed over) to the catheter used in the other randomization arm, but patients remained in the original group following intention-to-treat analysis. The selected endpoint could be achieved in all patients after 12 +/- 6 RFC pulses in group A and 10 +/- 7 RFC pulses in group B (P = 0.11). Procedure times were longer (159 +/- 38 min vs 138 +/- 37 min, P = 0.002) and x-ray exposures higher in group A (fluoroscopy time 25 +/- 17 min vs 21 +/- 10 min, P = 0.08; x-ray dosage 3,133 +/- 2,576 cGy . cm(2) vs 2,326 +/- 1,405 cGy . cm, P = 0.03). Transient isthmus block was observed in 23 group A patients and 12 group B patients (P = 0.03). Onset time of transient isthmus block ranged from 0.5 to 27 minutes. Repeated transient isthmus block occurred in 8 of the 23 patients in group A after 19 3 RFC applications. After crossover to the cooled-tip catheter, the endpoint was reached another 5 I RFC pulses. In group B, all patients could be treated without change of ablation catheter. After a follow-up of 14 +/- 2 months, 2 patients (3%) in group A and 1 patient (1.5%) in group B presented with AFL recurrence. Conclusion: Open cooled-tip catheters are more effective than solid large-tip catheters for AFL ablation. The greater effectiveness is evident in cases showing repeated conduction recovery within the cavotricuspid isthmus. Primary use of open irrigated-tip catheters should be considered for AFL ablation.
引用
收藏
页码:1126 / 1130
页数:5
相关论文
共 50 条
  • [41] The sawtooth EKG pattern of typical atrial flutter is not related to slow conduction velocity at the cavotricuspid isthmus
    Sau, Arunashis
    Sikkel, Markus B.
    Luther, Vishal
    Wright, Ian
    Guerrero, Fernando
    Koa-Wing, Michael
    Lefroy, David
    Linton, Nicholas
    Qureshi, Norman
    Whinnett, Zachary
    Lim, Phang Boon
    Kanagaratnam, Prapa
    Peters, Nicholas S.
    Davies, D. Wyn
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (12) : 1445 - 1453
  • [42] Radiofrequency ablation of atypical atrial flutter following cardiac surgery or atrial fibrillation ablation - Comparison of open irrigation-tip versus 8mm-tip catheters
    Bai, Rong
    Di Biase, Luigi
    Patel, Dimpi
    Fahmy, Tamer S.
    Ching, Chi Keong
    Prasad, Subramanya
    Popova, Lucie
    Elayi, Claude S.
    Wazni, Oussama M.
    Cummings, Jennifer E.
    Schweikert, Robert A.
    Burkhardt, J. David
    Martin, David
    Dresing, Thomas
    Saliba, Walid
    Tchou, Patrick
    Arruda, Mauricio
    Natale, Andrea
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 29A - 29A
  • [43] Radiofrequency ablation of atypical atrial flutter after cardiac surgery or atrial fibrillation ablation: A randomized comparison of open-irrigation-tip and 8-mm-tip catheters
    Bai, Rong
    Fahmy, Tamer S.
    Patel, Dimpi
    Di Biase, Luigi
    Riedlbauchova, Lucie
    Wazni, Oussama M.
    Schweikert, Robert A.
    Burkhardt, J. David
    Saliba, Walid
    Natale, Andrea
    HEART RHYTHM, 2007, 4 (12) : 1489 - 1496
  • [44] Characteristics of virtual unipolar electrograms for detecting isthmus block during radiofrequency ablation of typical atrial flutter
    Lin, YJ
    Tai, CT
    Huang, JL
    Liu, TY
    Lee, PC
    Ting, CT
    Chen, SA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (12) : 2300 - 2304
  • [45] Sharp Potential in Cavo-tricuspid Isthmus Targeted during Typical Atrial Flutter Radiofrequency Ablation
    Rey, Florian
    Sunthorn, Henri
    HEART LUNG AND CIRCULATION, 2016, 25 (03): : E46 - E47
  • [46] Age predicts the amount of radiofrequency energy required for the cavotricuspid isthmus block in typical atrial flutter ablation
    Perez-Rodon, J.
    Moya, A.
    Sarrias, A.
    Rivas, N.
    Roca, I.
    Dorado, D. Garcia
    EUROPEAN HEART JOURNAL, 2010, 31 : 560 - 560
  • [47] Pseudorestrictive Doppler flow pattern after radiofrequency ablation for isthmus-dependent atrial flutter
    Kelley, GP
    Dalati, G
    Jain, N
    Al-Bataineh, M
    Helmcke, FR
    Glancy, DL
    JOURNAL OF INVESTIGATIVE MEDICINE, 2005, 53 (01) : S268 - S268
  • [48] A prospective randomized comparison of irrigated catheter ablation versus conventional tip catheters for ablation of typical atrial flutter
    Jais, P
    Shah, DC
    Halssaguerre, M
    Takahashi, A
    Peng, JT
    Hocini, M
    Lavergne, T
    Garrigue, S
    Clementy, J
    CIRCULATION, 1999, 100 (18) : 652 - 652
  • [49] Simultaneous pulmonary vein cryoablation and cavotricuspid isthmus radiofrequency ablation in patients with combined atrial fibrillation and typical atrial flutter
    Peyrol, Michael
    Sbragia, Pascal
    Ronchard, Thibault
    Cautela, Jennifer
    Villacampa, Chloe
    Laine, Marc
    Bonello, Laurent
    Thuny, Franck
    Paganelli, Franck
    Levy, Samuel
    JOURNAL OF ELECTROCARDIOLOGY, 2015, 48 (04) : 729 - 733
  • [50] Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8-or 10-mm electrode catheters and a high-output radiofrequency energy generator - Results of a multicenter safety and efficacy study
    Feld, G
    Wharton, M
    Plumb, V
    Daoud, E
    Friehling, T
    Epstein, L
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (08) : 1466 - 1472