Quantitative accuracy of 177Lu SPECT imaging for molecular radiotherapy

被引:19
|
作者
Mezzenga, Emilio [1 ]
D'Errico, Vincenzo [1 ]
D'Arienzo, Marco [2 ]
Strigari, Lidia [3 ]
Panagiota, Koutla [4 ]
Matteucci, Federica [5 ]
Severi, Stefano [5 ]
Paganelli, Giovanni [5 ]
Fenwick, Andrew [6 ]
Bianchini, David [1 ]
Marcocci, Francesco [1 ]
Sarnelli, Anna [1 ]
机构
[1] IRCCS, Ist Sci Romagnolo Studio & Cura Tumori IRST, Med Phys Unit, Meldola, Italy
[2] ENEA CR Casaccia, Natl Inst Ionizing Radiat Metrol, Rome, Italy
[3] Regina Elena Inst Canc Res, Lab Med Phys & Expert Syst, Rome, Italy
[4] Aristotle Univ Thessaloniki, Dept Phys, Thessaloniki, Greece
[5] IRCCS, Ist Sci Romagnolo Studio & Cura Tumori IRST, Nucl Med Unit, Meldola, Italy
[6] Natl Phys Lab, Hampton Rd, Teddington, Middx, England
来源
PLOS ONE | 2017年 / 12卷 / 08期
关键词
RECEPTOR RADIONUCLIDE THERAPY; PROSTATE-CANCER; DOSIMETRY; RECONSTRUCTION; VALIDATION; PATIENT;
D O I
10.1371/journal.pone.0182888
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of this study is to investigate the optimal reference geometry for gamma camera calibration. Yet another question of interest was to assess the influence of the number of 3D Ordered Subsets Expectation Maximization (3D-OSEM) updates on activity quantification for SPECT imaging with Lu-177. The accuracy of Lu-177 activity quantification was assessed both in small and in large objects. Two different reference geometries, namely a cylindrical homogeneous phantom and a Jaszczak 16 ml sphere surrounded by cold water, were used to determine the gamma camera calibration factor of a commercial SPECT/CT system. Moreover, the noise level and the concentration recovery coefficient were evaluated as a function of the number of 3D-OSEM updates by using the SPECT/CT images of the reference geometry phantoms and those of a cold Jaszczak phantom with three hot spheres (16ml, 8ml and 4ml), respectively. The optimal choice of the number of 3D-OSEM updates was based on a compromise between the noise level achievable in the reconstructed SPECT images and the concentration recovery coefficients. The quantitative accuracy achievable was finally validated on a test phantom, where a spherical insert composed of two concentric spheres was used to simulate a lesion in a warm background. Our data confirm and extend previous observations. Using the calibration factor obtained with the cylindrical homogeneous phantom and the Jaszczak 16 ml sphere, the recovered activity in the test phantom was underestimated by -16.4% and -24.8%, respectively. Our work has led us to conclude that gamma camera calibration performed with large homogeneous phantom outperforms calibration executed with the Jaszczak 16ml sphere. Furthermore, the results obtained support the assumption that approximately 50 OSEM updates represent a good trade-off to reach convergence in small volumes, meanwhile minimizing the noise level.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] An international quantitative SPECT/CT imaging exercise for Lu-177
    Tran-Gia, J.
    Robinson, A. P.
    Calvert, N.
    Denis-Bacelar, A. M.
    Fenwick, A. J.
    Ferreira, K. M.
    Finocchiaro, D.
    Fioroni, F.
    Grassi, E.
    Heetun, W.
    Jewitt, S. J.
    Kalathas, T.
    Kotzasarlidou, M.
    Ljungberg, M.
    McGowan, D. R.
    Scuffham, J.
    Gleisner, K. Sjogreen
    Tipping, J.
    Wevrett, J.
    Lassmann, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S15 - S16
  • [32] Quantitative SPECT imaging with Lu-177: A physical phantom evaluation
    He, Bin
    Nikolopoulou, Anastasia
    Osborne, Joseph
    Vallabhajosula, Shankar
    Goldsmith, Stanley
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [33] In Vitro Evaluation of Targeted Antisense 177Lu Radiotherapy
    Balkin, Ethan R.
    Jia, Fang
    Miller, William H.
    Lewis, Michael R.
    ANTICANCER RESEARCH, 2011, 31 (10) : 3143 - 3149
  • [34] Evaluation of Repeatability of 177Lu Quantitative Imaging Using Monte Carlo Simulation
    Ishikawa, K.
    Kubota, C.
    Yasumoto, Y.
    Sakashita, T.
    Daisaki, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S738 - S739
  • [35] Generation of realistic SPECT/CT images for 177Lu dosimetry in Molecular Radiotherapy (MRT) based on Monte Carlo simulation with GATE
    Kayal, G.
    Chauvin, M.
    Vergara-Gil, A.
    Clayton, N.
    Struelens, L.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S319 - S319
  • [36] An Assessment of the Accuracy of Quantitative SPECT/CT Imaging Using Tc99m and Lu177
    Johnson, J.
    Adamson, K.
    Alkahtani, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S254 - S255
  • [37] Quantitative 177Lu SPECT/CT imaging for personalized dosimetry using a ring-shaped CZT-based camera
    Rachele Danieli
    Martina Stella
    Julian Leube
    Johannes Tran-Gia
    Clementine Marin
    Carlos F. Uribe
    Bruno Vanderlinden
    Nick Reynaert
    Patrick Flamen
    Hugo Levillain
    EJNMMI Physics, 10
  • [38] Comparison of quantitative 177Lu measurements in European hospitals
    Fenwick, A.
    Merrett, J.
    Johansson, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S38 - S39
  • [39] Quantitative 177Lu SPECT/CT imaging for personalized dosimetry using a ring-shaped CZT-based camera
    Danieli, Rachele
    Stella, Martina
    Leube, Julian
    Tran-Gia, Johannes
    Marin, Clementine
    Uribe, Carlos F.
    Vanderlinden, Bruno
    Reynaert, Nick
    Flamen, Patrick
    Levillain, Hugo
    EJNMMI PHYSICS, 2023, 10 (01)
  • [40] Comprehensive SPECT/CT system characterization and calibration for 177Lu quantitative SPECT (QSPECT) with dead-time correction
    Andrea Frezza
    Corentin Desport
    Carlos Uribe
    Wei Zhao
    Anna Celler
    Philippe Després
    Jean-Mathieu Beauregard
    EJNMMI Physics, 7