Quantitative accuracy of 177Lu SPECT imaging for molecular radiotherapy

被引:19
|
作者
Mezzenga, Emilio [1 ]
D'Errico, Vincenzo [1 ]
D'Arienzo, Marco [2 ]
Strigari, Lidia [3 ]
Panagiota, Koutla [4 ]
Matteucci, Federica [5 ]
Severi, Stefano [5 ]
Paganelli, Giovanni [5 ]
Fenwick, Andrew [6 ]
Bianchini, David [1 ]
Marcocci, Francesco [1 ]
Sarnelli, Anna [1 ]
机构
[1] IRCCS, Ist Sci Romagnolo Studio & Cura Tumori IRST, Med Phys Unit, Meldola, Italy
[2] ENEA CR Casaccia, Natl Inst Ionizing Radiat Metrol, Rome, Italy
[3] Regina Elena Inst Canc Res, Lab Med Phys & Expert Syst, Rome, Italy
[4] Aristotle Univ Thessaloniki, Dept Phys, Thessaloniki, Greece
[5] IRCCS, Ist Sci Romagnolo Studio & Cura Tumori IRST, Nucl Med Unit, Meldola, Italy
[6] Natl Phys Lab, Hampton Rd, Teddington, Middx, England
来源
PLOS ONE | 2017年 / 12卷 / 08期
关键词
RECEPTOR RADIONUCLIDE THERAPY; PROSTATE-CANCER; DOSIMETRY; RECONSTRUCTION; VALIDATION; PATIENT;
D O I
10.1371/journal.pone.0182888
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of this study is to investigate the optimal reference geometry for gamma camera calibration. Yet another question of interest was to assess the influence of the number of 3D Ordered Subsets Expectation Maximization (3D-OSEM) updates on activity quantification for SPECT imaging with Lu-177. The accuracy of Lu-177 activity quantification was assessed both in small and in large objects. Two different reference geometries, namely a cylindrical homogeneous phantom and a Jaszczak 16 ml sphere surrounded by cold water, were used to determine the gamma camera calibration factor of a commercial SPECT/CT system. Moreover, the noise level and the concentration recovery coefficient were evaluated as a function of the number of 3D-OSEM updates by using the SPECT/CT images of the reference geometry phantoms and those of a cold Jaszczak phantom with three hot spheres (16ml, 8ml and 4ml), respectively. The optimal choice of the number of 3D-OSEM updates was based on a compromise between the noise level achievable in the reconstructed SPECT images and the concentration recovery coefficients. The quantitative accuracy achievable was finally validated on a test phantom, where a spherical insert composed of two concentric spheres was used to simulate a lesion in a warm background. Our data confirm and extend previous observations. Using the calibration factor obtained with the cylindrical homogeneous phantom and the Jaszczak 16 ml sphere, the recovered activity in the test phantom was underestimated by -16.4% and -24.8%, respectively. Our work has led us to conclude that gamma camera calibration performed with large homogeneous phantom outperforms calibration executed with the Jaszczak 16ml sphere. Furthermore, the results obtained support the assumption that approximately 50 OSEM updates represent a good trade-off to reach convergence in small volumes, meanwhile minimizing the noise level.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Variability of Quantitative Values by Organ/Lesion Location in Quantitative 177Lu Imaging
    Shiga, M.
    Daisaki, H.
    Ogawa, M.
    Isogai, S.
    Sato, M.
    Kubota, C.
    Sakashita, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S800 - S800
  • [22] Quantitative SPECT/CT Imaging of 177Lu with In Vivo Validation in Patients Undergoing Peptide Receptor Radionuclide Therapy
    Sanders, J. C.
    Kuwert, T.
    Hornegger, J.
    Ritt, P.
    MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (04) : 585 - 593
  • [23] Quantitative SPECT/CT Imaging of 177Lu with In Vivo Validation in Patients Undergoing Peptide Receptor Radionuclide Therapy
    J. C. Sanders
    T. Kuwert
    J. Hornegger
    P. Ritt
    Molecular Imaging and Biology, 2015, 17 : 585 - 593
  • [24] Implementation of EARL 177Lu Quantitative SPECT Accreditation on 360° CZT SPECT-CT Camera
    Dumouchel, A.
    Koudia, A.
    Francois, M.
    Bohn, P.
    Dieudonne, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S721 - S721
  • [25] Change in activity uptake between treatment cycles in quantitative 177Lu SPECT/CT
    Bonney, L.
    McGowan, D. R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S644 - S644
  • [26] Generation of clinical 177Lu SPECT/CT images for dosimetry in Molecular Radiotherapy based on Monte Carlo simulation with GATE
    Kayal, Gunjan
    Chauvin, Maxime
    Gil, Alex-Vergara
    Clayton, Naomi
    Ferrer, Ludovic
    Moalosi, Tumelo
    Knoll, Peter
    Struelens, Lara
    Bardies, Manuel
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [27] Inter-comparison of quantitative imaging of lutetium-177 (177Lu) in European hospitals
    Wevrett, Jill
    Fenwick, Andrew
    Scuffham, James
    Johansson, Lena
    Gear, Jonathan
    Schlogl, Susanne
    Segbers, Marcel
    Sjogreen-Gleisner, Katarina
    Solny, Pavel
    Lassmann, Michael
    Tipping, Jill
    Nisbet, Andrew
    EJNMMI PHYSICS, 2018, 5
  • [28] Inter-comparison of quantitative imaging of lutetium-177 (177Lu) in European hospitals
    Jill Wevrett
    Andrew Fenwick
    James Scuffham
    Lena Johansson
    Jonathan Gear
    Susanne Schlögl
    Marcel Segbers
    Katarina Sjögreen-Gleisner
    Pavel Solný
    Michael Lassmann
    Jill Tipping
    Andrew Nisbet
    EJNMMI Physics, 5
  • [29] Deep learning based partial volume correction for 177Lu SPECT/CT imaging
    Leube, Julian
    Gustafsson, Johan
    Lassmann, Michael
    Salas-Ramirez, Maikol
    Tran-Gia, Johannes
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [30] A Deep-Learning-Based Partial-Volume Correction Method for Quantitative 177Lu SPECT/CT Imaging
    Leube, Julian
    Gustafsson, Johan
    Lassmann, Michael
    Salas-Ramirez, Maikol
    Tran-Gia, Johannes
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65 (06) : 980 - 987