A layer-by-layer assembly label-free electrochemical immunosensor for the detection of microcystin-LR based on CHIT/PAMAM dendrimer/silver nanocubes

被引:2
|
作者
Fu, Xuewen [1 ]
Zhao, Chunling [1 ]
Liu, Xiaohai [2 ]
Zhao, Jinhang [1 ]
Niu, Xiaofang [1 ]
Zheng, Li [1 ]
Yang, Yunhui [1 ]
机构
[1] Yunnan Normal Univ, Coll Chem & Chem Engn, Kunming, Peoples R China
[2] Yunnan Inst Environm Sci, Environm Anal & Testing Ctr, Kunming, Peoples R China
基金
中国国家自然科学基金;
关键词
label-free immunosensor; silver nanocubes; microcystins-LR; G4-polyamidoamine dendrimer; SILVER NANOPARTICLES; SENSITIVE DETECTION; RAPID DETECTION; SAMPLES; IMMUNOASSAY; BIOSENSOR; ELECTRODE; WATER; NANOTECHNOLOGY; AMPLIFICATION;
D O I
10.1080/03067319.2016.1150460
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Utilising the affinity and high combination ability between silver nanocubes and amino group (-NH2), a novel electrochemical immunosensor was constructed for the ultrasensitive detection of microcystin-LR (MC-LR) based on G4-polyamidoamine (PAMAM) dendrimer and Ag nanocubes as immobilised substrate of anti-MC-LR. G4-PAMAM dendrimers were covalently bound on the chitosan (CHIT) - modified electrode by glutaraldehyde (GA), providing abundant amino groups to absorb much more Ag nanocubes comparing without using PAMAM. Subsequently, antibodies of MC-LR were immobilised with highly dense through Ag-NH2. K3Fe(CN)(6)/K4Fe(CN)(6) was used as electroactive redox probe. Ag nanocubes/PAMAM can enhance the antibody loading amount, which would bind more MC-LR and hinder the electron transfer of K3Fe(CN)(6)/K4Fe(CN)(6). Differential pulse voltammetry (DPV) was employed to evaluate the analytical performance of the fabricated signal-off immunosensor. The response current had negative correlation with the concentration of MC-LR. The linear range covered was from 0.05ng/mL to 25 mu g/mL with detection limit (DL) of 0.017ng/mL at 3 sigma. The proposed approach showed high specificity for the detection of MC-LR, with acceptable reproducibility, stability and reliability. Compared with the enzyme-linked immunoassay (ELISA) method by analyzing real water samples from Dian Lake, this immunosensor revealed acceptable accuracy with a relative error of 12.7%, indicating a potential alternative method for MC-LR detection in water sample.
引用
收藏
页码:284 / 297
页数:14
相关论文
共 50 条
  • [41] Cytokine immunosensor for multiple sclerosis detection based upon label-free electrochemical impedance spectroscopy
    La Belle, Jeffrey T.
    Bhavsar, Kinjal
    Fairchild, Aaron
    Das, Anusuya
    Sweeney, James
    Alford, T. L.
    Wang, Joseph
    Bhavanandan, Veer P.
    Joshi, Lokesh
    BIOSENSORS & BIOELECTRONICS, 2007, 23 (03): : 428 - 431
  • [42] A Label-Free Electrochemical Immunosensor for Carbofuran Detection Based on a Sol-Gel Entrapped Antibody
    Sun, Xia
    Du, Shuyuan
    Wang, Xiangyou
    Zhao, Wenping
    Li, Qingqing
    SENSORS, 2011, 11 (10) : 9520 - 9531
  • [43] A label-free small molecular hydrogel-based electrochemical immunosensor for ultrasensitive detection of deoxynivalenol
    Peng, Yu
    Geng, Lifang
    Liu, Xinyi
    Liu, Min
    Wu, Haoru
    Li, Jingjing
    ANALYTICAL METHODS, 2019, 11 (47) : 5948 - 5952
  • [44] Ultrasensitive Label-free Electrochemical Immunosensor based on Multifunctionalized Graphene Nanocomposites for the Detection of Alpha Fetoprotein
    Yaoguang Wang
    Yong Zhang
    Dan Wu
    Hongmin Ma
    Xuehui Pang
    Dawei Fan
    Qin Wei
    Bin Du
    Scientific Reports, 7
  • [45] Label-free paper-based electrochemical impedance immunosensor for human interferon gamma detection
    Ruecha, Nipapan
    Shin, Kwanwoo
    Chailapakul, Orawon
    Rodthongkum, Nadnudda
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 279 : 298 - 304
  • [46] Ultrasensitive Label-free Electrochemical Immunosensor based on Multifunctionalized Graphene Nanocomposites for the Detection of Alpha Fetoprotein
    Wang, Yaoguang
    Zhang, Yong
    Wu, Dan
    Ma, Hongmin
    Pang, Xuehui
    Fan, Dawei
    Wei, Qin
    Du, Bin
    SCIENTIFIC REPORTS, 2017, 7
  • [47] Label-free Detection of Microcystin-LR in Waters Using Real-Time Potentiometric Biosensors Based on Single-Walled Carbon Nanotubes Imprinted Polymers
    Queiros, Raquel B.
    Noronha, J. P.
    Marques, P. V. S.
    Sales, M. G. F.
    26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 758 - 761
  • [48] Label-free Pb2+ detection on the layer-by-layer platform using real-time dual polarization interferometry
    Wang, Shuang
    Lu, Shasha
    Zhao, Jiahui
    Huang, Jianshe
    Yang, Xiurong
    TALANTA, 2019, 202 : 336 - 341
  • [49] Label-free peptide aptamer based impedimetric biosensor for highly sensitive detection of TNT with a ternary assembly layer
    Li, Yanyan
    Zhao, Manru
    Wang, Haiyan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (27) : 6371 - 6377
  • [50] Label-free peptide aptamer based impedimetric biosensor for highly sensitive detection of TNT with a ternary assembly layer
    Yanyan Li
    Manru Zhao
    Haiyan Wang
    Analytical and Bioanalytical Chemistry, 2017, 409 : 6371 - 6377