Label-free paper-based electrochemical impedance immunosensor for human interferon gamma detection

被引:101
|
作者
Ruecha, Nipapan [1 ]
Shin, Kwanwoo [2 ,3 ]
Chailapakul, Orawon [4 ]
Rodthongkum, Nadnudda [1 ]
机构
[1] Chulalongkorn Univ, Met & Mat Sci Res Inst, Bangkok, Thailand
[2] Sogang Univ, Dept Chem, Seoul, South Korea
[3] Sogang Univ, Inst Biol Interfaces, Seoul, South Korea
[4] Chulalongkorn Univ, Fac Sci, Dept Chem, Electrochem & Opt Spect Ctr Excellence, Bangkok, Thailand
关键词
Human interferon-gamma; Paper-based device; Immunosensor; Electrochemical impedance spectroscopy; Polyaniline; Graphene; Nanocomposite; IFN-GAMMA; MODIFIED ELECTRODES; TNF-ALPHA; GRAPHENE; NANOCOMPOSITE; BIOSENSOR; POLYANILINE; APTASENSOR; SURFACE; SENSOR;
D O I
10.1016/j.snb.2018.10.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Human interferon-gamma (IFN-gamma) plays an important role in diagnosis of tuberculosis susceptibility, which is one of the crucial health problems worldwide. Here, a novel platform of paper-based microfluidic device coupled with label-free electrochemical impedance immunosensor was developed for sensitive detection of human IFN-gamma. Polyaniline (PANI) was deposited on a graphene (G) screen-printed paper electrode by using cyclic voltammetry. The modified electrode provides high electrochemical conductivity and surface area for antibody immobilization, which significantly enhances the sensitivity. A linear relationship between impedance and logarithmic concentrations of human IFN-gamma was found in a range of 5-1000 pg mL(-1) with a detection limit (LOD) of 3.4 pg mL(-1). Interestingly, the PANI-G modified electrodes display 31-fold higher sensitivity compared to PANI-modified electrodes. The PANI-G modified electrode was successfully applied to the determination of human IFN-gamma in human serum with a good reproducibility. Moreover, the system offers several advantages including low cost, low sample volume requirement, disposability, and rapid analysis relative to traditional methods, allowing the platform to be used as an alternative tool for human IFN-gamma screening.
引用
收藏
页码:298 / 304
页数:7
相关论文
共 50 条
  • [1] Label-free Paper-based Immunosensor with Graphene Nanocomposites for Electrochemical Detection of Follicle-stimulating Hormone
    Luo, Jinping
    Kong, Zhuang
    Wang, Yang
    Xie, Jingyu
    Liu, Juntao
    Jin, Hongyan
    Cai, Xinxia
    [J]. 2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 2901 - 2904
  • [2] A novel label-free microfluidic paper-based immunosensor for highly sensitive electrochemical detection of carcinoembryonic antigen
    Wang, Yang
    Xu, Huiren
    Luo, Jinping
    Liu, Juntao
    Wang, Li
    Fan, Yan
    Yan, Shi
    Yang, Yue
    Cai, Xinxia
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 83 : 319 - 326
  • [3] Label-free simultaneous detection of quinolone antibiotic residues using an origami paper-based electrochemical immunosensor
    Chomthong, Kittima
    Kunpatee, Kanjana
    Pimpitak, Umaporn
    Puthong, Songchan
    Komolpis, Kittinan
    Wonsawat, Wanida
    Nuanualsuwan, Suphachai
    Yakoh, Abdulhadee
    Khongchareonporn, Nanthika
    Ruecha, Nipapan
    Chaiyo, Sudkate
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2024, 410
  • [4] A MXene-functionalized paper-based electrochemical immunosensor for label-free detection of cardiac troponin I
    Li Wang
    Yufeng Han
    Hongchen Wang
    Yaojie Han
    Jinhua Liu
    Gang Lu
    Haidong Yu
    [J]. Journal of Semiconductors, 2021, (09) - 64
  • [5] A MXene-functionalized paper-based electrochemical immunosensor for label-free detection of cardiac troponin I
    Li Wang
    Yufeng Han
    Hongchen Wang
    Yaojie Han
    Jinhua Liu
    Gang Lu
    Haidong Yu
    [J]. Journal of Semiconductors, 2021, 42 (09) : 57 - 64
  • [6] A MXene-functionalized paper-based electrochemical immunosensor for label-free detection of cardiac troponin I
    Wang, Li
    Han, Yufeng
    Wang, Hongchen
    Han, Yaojie
    Liu, Jinhua
    Lu, Gang
    Yu, Haidong
    [J]. JOURNAL OF SEMICONDUCTORS, 2021, 42 (09)
  • [7] Tungsten disulfide nanotubes enhanced nanocomposite paper-based aptasensor for label-free electrochemical detection of interferon-gamma
    Yeh, Ya-Shin
    Yen, Yi-Kuang
    Shanmugam, Ragurethinam
    [J]. MICROCHEMICAL JOURNAL, 2023, 193
  • [8] Cost-effective paper-based electrochemical immunosensor using a label-free assay for sensitive detection of ferritin
    Boonkaew, Suchanat
    Teengam, Prinjaporn
    Jampasa, Sakda
    Rengpipat, Sirirat
    Siangproh, Weena
    Chailapakul, Orawon
    [J]. ANALYST, 2020, 145 (14) : 5019 - 5026
  • [9] On the response of a label-free interferon-γ immunosensor utilizing electrochemical impedance spectroscopy
    Bart, M
    Stigter, ECA
    Stapert, HR
    de Jong, GJ
    van Bennekom, WP
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 21 (01): : 49 - 59
  • [10] Paper-based immunosensor utilizing dielectrophoretic trapping of microprobes for quantitative and label free detection using electrochemical impedance spectroscopy
    Shaikh, Muhammad Omar
    Chang, Lung-Yu
    Chen, Cheng-Ho
    Wu, Ting-Feng
    Chuang, Cheng-Hsin
    [J]. BIOMICROFLUIDICS, 2018, 12 (06):