A note on estimation of diffuse radiation collected by all-glass evacuated solar tube collectors

被引:0
|
作者
Zhang, Yougang [1 ]
Tang, Runsheng [1 ]
机构
[1] Yunnan Normal Univ, Educ Minist, Key Lab Adv Technol & Preparat Renewable Energy M, Kunming 650500, Yunnan, Peoples R China
关键词
2‐ D diffuse radiation model; 3‐ comparison of estimates; estimation of collectible diffuse radiation; evacuated tube solar collector; DESIGN OPTIMIZATION; MATHEMATICAL-MODEL; V-TROUGH; PERFORMANCE; CPCS; REFLECTIONS;
D O I
10.1002/er.6792
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To simplify the estimation of diffuse radiation from the sky and ground collected by all-glass evacuated solar tube collectors (ETCs), four methods were proposed and used in the past. Among them, the one by assuming the directional intensity of diffuse radiation projected on the plane coplanar with cross-section of solar tubes (2-D model) to be isotropic is simpler as mathematical expressions for the estimate of diffuse collectible radiation can be directly derived in this case. However, such assumption is not true for tilted evacuated solar tubes (ET), and the three-dimensional isotropic diffuse radiation (3-D model) should be used. In this note, a trail is made to estimate diffuse radiation collected by tilted-arranged ET collectors (T-type ETC) based on 3-D model and compare with those obtained based on the 2-D model. Results show that the diffuse radiation collected by T-type ETCs estimated based on 2-D and 3-D models are highly in agreement, and the difference between two estimates is dependent on the tilt-angle (beta) of ETCs. For the case of beta = 0 and 90 degrees, the both estimates are completely identical as expected. For T-type ETCs with ETs sizing 47/58 mm in diameter of inner/outer tubes and spacing (B) between centers of two adjacent ETs less than 80 mm, the relative deviation between two estimates for diffuse radiation from the sky is less than 0.65% and that for diffuse radiation reflecting from the ground is less than 1.7% when beta > 20 degrees. This means that the 2-D model is reasonable and advisable for a quick estimation of collectible diffuse radiation of ETCs.
引用
收藏
页码:15586 / 15594
页数:9
相关论文
共 50 条
  • [41] An all-glass distilling tube without constriction
    Lucas, HJ
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1927, 19 (01): : 680 - 680
  • [42] Vertical evacuated tubular-collectors utilizing solar radiation from all directions
    Shah, LJ
    Furbo, S
    APPLIED ENERGY, 2004, 78 (04) : 371 - 395
  • [43] Experimental study on direct pass all-glass evacuated tubular solar air collectorand drying application
    Wang, Yunfeng
    Chang, Wei
    Li, Ming
    Li, Guoliang
    Luo, Xi
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (01): : 21 - 28
  • [44] High temperature collecting performance of a new all-glass evacuated tubular solar air heater with U-shaped tube heat exchanger
    Wang, Pin-Yang
    Guan, Hong-Yang
    Liu, Zhen-Hua
    Wang, Guo-San
    Zhao, Feng
    Xiao, Hong-Sheng
    ENERGY CONVERSION AND MANAGEMENT, 2014, 77 : 315 - 323
  • [45] Improving the experimental estimation of the incident angle modifier of evacuated tube solar collectors with heat pipes
    Rodriguez-Munoz, J. M.
    Bove, I.
    Alonso-Suarez, R.
    RENEWABLE ENERGY, 2024, 235
  • [46] A review study of solar desalting units with evacuated tube collectors
    Singh, Ashok Kumar
    Samsher
    JOURNAL OF CLEANER PRODUCTION, 2021, 279
  • [47] An up-to-date review on evacuated tube solar collectors
    Kumar, Arvind
    Said, Zafar
    Bellos, Evangelos
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (06) : 2873 - 2889
  • [48] Numerical analysis of evacuated tube solar collectors using nanofluids
    Mercan, Muhammed
    Yurddas, Ali
    SOLAR ENERGY, 2019, 191 : 167 - 179
  • [49] VACUUM MAINTENANCE OF ALL-glass VACUUM TUBULAR COLLECTORS.
    Wu Jia-qing
    Tao Zu-yan
    Wang Feng-chun
    Li Shi-Lian
    Ching Hua Ta Hsueh Hsueh Pao/ Journal of Ching Hua University, 1982, 22 (02): : 89 - 98
  • [50] An up-to-date review on evacuated tube solar collectors
    Arvind Kumar
    Zafar Said
    Evangelos Bellos
    Journal of Thermal Analysis and Calorimetry, 2021, 145 : 2873 - 2889