A note on estimation of diffuse radiation collected by all-glass evacuated solar tube collectors

被引:0
|
作者
Zhang, Yougang [1 ]
Tang, Runsheng [1 ]
机构
[1] Yunnan Normal Univ, Educ Minist, Key Lab Adv Technol & Preparat Renewable Energy M, Kunming 650500, Yunnan, Peoples R China
关键词
2‐ D diffuse radiation model; 3‐ comparison of estimates; estimation of collectible diffuse radiation; evacuated tube solar collector; DESIGN OPTIMIZATION; MATHEMATICAL-MODEL; V-TROUGH; PERFORMANCE; CPCS; REFLECTIONS;
D O I
10.1002/er.6792
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To simplify the estimation of diffuse radiation from the sky and ground collected by all-glass evacuated solar tube collectors (ETCs), four methods were proposed and used in the past. Among them, the one by assuming the directional intensity of diffuse radiation projected on the plane coplanar with cross-section of solar tubes (2-D model) to be isotropic is simpler as mathematical expressions for the estimate of diffuse collectible radiation can be directly derived in this case. However, such assumption is not true for tilted evacuated solar tubes (ET), and the three-dimensional isotropic diffuse radiation (3-D model) should be used. In this note, a trail is made to estimate diffuse radiation collected by tilted-arranged ET collectors (T-type ETC) based on 3-D model and compare with those obtained based on the 2-D model. Results show that the diffuse radiation collected by T-type ETCs estimated based on 2-D and 3-D models are highly in agreement, and the difference between two estimates is dependent on the tilt-angle (beta) of ETCs. For the case of beta = 0 and 90 degrees, the both estimates are completely identical as expected. For T-type ETCs with ETs sizing 47/58 mm in diameter of inner/outer tubes and spacing (B) between centers of two adjacent ETs less than 80 mm, the relative deviation between two estimates for diffuse radiation from the sky is less than 0.65% and that for diffuse radiation reflecting from the ground is less than 1.7% when beta > 20 degrees. This means that the 2-D model is reasonable and advisable for a quick estimation of collectible diffuse radiation of ETCs.
引用
收藏
页码:15586 / 15594
页数:9
相关论文
共 50 条
  • [31] Experimental and simulate study on the performance of all-glass evacuated-tube solar collector hot-water system
    Lin, Xin Xing, 1600, Sila Science, University Mah Mekan Sok, No 24, Trabzon, Turkey (32):
  • [32] Study on measurement of thermal performance of all-glass evacuated tubular solar air heater
    Wang, Z.F.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2001, 22 (02): : 141 - 147
  • [33] Natural circulation flow through water-in-glass evacuated tube solar collectors
    Budihardjo, Indra
    Morrison, Graham L.
    Behnia, Masud
    SOLAR ENERGY, 2007, 81 (12) : 1460 - 1472
  • [34] Observation and modeling of dust deposition on glass tube of evacuated solar thermal collectors in Mongolia
    Erdenedavaa, Purevdalai
    Akisawa, Atsushi
    Adiyabat, Amarbayar
    Otgonjanchiv, Erdenesuvd
    RENEWABLE ENERGY, 2019, 130 : 613 - 621
  • [35] Optical performance of CPCs suitable for all-glass evacuated tubes
    Solar Energy Research Institute, Yunnan Normal University, Kunming
    Yunnan
    650092, China
    Zhongguo Jiguang,
  • [36] Thermal modeling of evacuated tube solar air collectors
    Paradis, Pierre-Luc
    Rousse, Daniel R.
    Halle, Stephane
    Lamarche, Louis
    Quesada, Guillermo
    SOLAR ENERGY, 2015, 115 : 708 - 721
  • [37] Exergy analysis of evacuated tube solar collectors: a review
    Saxena, Gaurav
    Gaur, Manoj Kumar
    INTERNATIONAL JOURNAL OF EXERGY, 2018, 25 (01) : 54 - 74
  • [38] Progress and latest developments of evacuated tube solar collectors
    Sabiha, M. A.
    Saidur, R.
    Mekhilef, Saad
    Mahian, Omid
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 51 : 1038 - 1054
  • [39] Energy and exergy analysis of all-glass evacuated solar collector tubes with coaxial fluid conduit
    Ataee, S.
    Ameri, M.
    SOLAR ENERGY, 2015, 118 : 575 - 591
  • [40] A study on correlation of solar radiation and energy collected from the evacuated tube solar heating system
    Akbar, Wanda Ali
    Shim, Kyu Jin
    Kim, Bo Han
    Seo, Jong Soo
    Chung, Han Shik
    Jeong, Hyo Min
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 719 - +