A note on estimation of diffuse radiation collected by all-glass evacuated solar tube collectors

被引:0
|
作者
Zhang, Yougang [1 ]
Tang, Runsheng [1 ]
机构
[1] Yunnan Normal Univ, Educ Minist, Key Lab Adv Technol & Preparat Renewable Energy M, Kunming 650500, Yunnan, Peoples R China
关键词
2‐ D diffuse radiation model; 3‐ comparison of estimates; estimation of collectible diffuse radiation; evacuated tube solar collector; DESIGN OPTIMIZATION; MATHEMATICAL-MODEL; V-TROUGH; PERFORMANCE; CPCS; REFLECTIONS;
D O I
10.1002/er.6792
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To simplify the estimation of diffuse radiation from the sky and ground collected by all-glass evacuated solar tube collectors (ETCs), four methods were proposed and used in the past. Among them, the one by assuming the directional intensity of diffuse radiation projected on the plane coplanar with cross-section of solar tubes (2-D model) to be isotropic is simpler as mathematical expressions for the estimate of diffuse collectible radiation can be directly derived in this case. However, such assumption is not true for tilted evacuated solar tubes (ET), and the three-dimensional isotropic diffuse radiation (3-D model) should be used. In this note, a trail is made to estimate diffuse radiation collected by tilted-arranged ET collectors (T-type ETC) based on 3-D model and compare with those obtained based on the 2-D model. Results show that the diffuse radiation collected by T-type ETCs estimated based on 2-D and 3-D models are highly in agreement, and the difference between two estimates is dependent on the tilt-angle (beta) of ETCs. For the case of beta = 0 and 90 degrees, the both estimates are completely identical as expected. For T-type ETCs with ETs sizing 47/58 mm in diameter of inner/outer tubes and spacing (B) between centers of two adjacent ETs less than 80 mm, the relative deviation between two estimates for diffuse radiation from the sky is less than 0.65% and that for diffuse radiation reflecting from the ground is less than 1.7% when beta > 20 degrees. This means that the 2-D model is reasonable and advisable for a quick estimation of collectible diffuse radiation of ETCs.
引用
收藏
页码:15586 / 15594
页数:9
相关论文
共 50 条
  • [1] Optimal tilt-angles of all-glass evacuated tube solar collectors
    Tang, Runsheng
    Gao, Wenfeng
    Yu, Yamei
    Chen, Hua
    ENERGY, 2009, 34 (09) : 1387 - 1395
  • [2] Experiment and simulation for convective heat transfer in all-glass evacuated tube solar collectors
    Zhang T.
    Han J.
    Tian R.
    Yu Z.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2016, 32 (05): : 206 - 212
  • [3] Self-Cleaning and antireflective films for all-glass evacuated tube solar collectors
    Yang, H. L.
    Hao, L.
    Wang, J. N.
    Zhang, Z. N.
    Liu, X. P.
    Jiang, L. J.
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, SOLARPACES 2014, 2015, 69 : 226 - 232
  • [4] Medium-temperature solar collectors with all-glass solar evacuated tubes
    Wang, Jian
    Yin, Zhiqiang
    Qi, Jing
    Ma, Guangbai
    Liu, Xijie
    INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY, SHC 2014, 2015, 70 : 126 - 129
  • [5] The Study of Solar Heat Pump with all-glass evacuated tube
    Gao, Jinshui
    Ge, Xin
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 778 - +
  • [6] HELIUM PERMEATION IN ALL-GLASS TUBULAR EVACUATED SOLAR-ENERGY COLLECTORS
    HARDING, GL
    SOLAR ENERGY MATERIALS, 1981, 5 (02): : 141 - 147
  • [7] PROGRESS IN THE MATERIALS SCIENCE OF ALL-GLASS EVACUATED COLLECTORS
    WINDOW, B
    HARDING, GL
    SOLAR ENERGY, 1984, 32 (05) : 609 - 623
  • [8] Experimental research on the all-glass evacuated tube solar air collector
    Liang, Hong
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 674 - 677
  • [9] An experimental study on the impacts of key parameters of all-glass evacuated tubes on the thermal performances of all-glass evacuated tube solar water heaters
    Ma, Fangfang
    Gao, Wenfeng
    Liu, Tao
    Lin, Wenxian
    Li, Ming
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2013, 5 (02)
  • [10] SUITABLE SELECTIVE ABSORBERS FOR ALL-GLASS, EVACUATED, TUBULAR, SOLAR-ENERGY COLLECTORS
    GARG, HP
    SHUKLA, AR
    AGNIHOTRI, RC
    CHAKRAVERTTY, S
    APPLIED ENERGY, 1983, 13 (04) : 295 - 315