Optimal Stent-Sizing With Intravascular Ultrasound Contributes to Complete Neointimal Coverage After Sirolimus-Eluting Stent Implantation Assessed by Angioscopy

被引:17
|
作者
Sera, Fusako [2 ]
Awata, Masaki [2 ]
Uematsu, Masaaki [2 ]
Kotani, Jun-ichi [1 ]
Nanto, Shinsuke [1 ,2 ]
Nagata, Seiki [2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Adv Cardiovasc Therapeut, Suita, Osaka 5650871, Japan
[2] Kansai Rosai Hosp, Ctr Cardiovasc, Amagasaki, Hyogo, Japan
关键词
angioscopy; intravascular ultrasound; neointima; sirolimus-eluting stent; PALMAZ-SCHATZ STENTS; CORONARY-ARTERY; LATE THROMBOSIS; ANTIPLATELET THERAPY; MORPHOLOGIC CHANGES; RADIATION-THERAPY; CLINICAL-TRIALS; TIME-COURSE; RESTENOSIS; PREDICTORS;
D O I
10.1016/j.jcin.2009.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aim of this study was to explore the determinants of neointimal coverage after sirolimus-eluting stent (SES). Background Although SES has significantly reduced in-stent restenosis by inhibiting neointimal hyperplasia, insufficient neointimal coverage after stenting might result in adverse outcomes. Methods We evaluated 28 SES lesions with both angioscopy and intravascular ultrasound (IVUS). Quantitative assessments of the lesions and stent expansion were performed by IVUS at the time of stent implantation, and degree of neointimal coverage was judged by angioscopy at follow-up (11 +/- 6 months) whether the stent struts were embedded by the neointima ("complete/incomplete" neointimal coverage). Results "Complete" coverage was identified in 10 (36%), and "incomplete" coverage was identified in 18 (64%). Time from the stenting to angioscopy as well as the lesion and procedural characteristics were similar between the complete and incomplete coverage groups. The IVUS parameters were also similar, except for the final minimum stent cross-sectional area (CSA) (7.0 +/- 1.8 mm(2) in complete vs. 5.3 +/- 1.9 mm(2) in incomplete, p = 0.02) and lumen CSA at the distal reference site (6.1 +/- 1.4 mm(2) in complete vs. 4.9 +/- 1.2 mm(2) in incomplete, p = 0.02). The ratio of the stent area to the vessel area was significantly larger in the complete coverage than in the incomplete coverage group (0.52 +/- 0.11 vs. 0.39 +/- 0.09, p = 0.002). Conclusions Adequate stent sizing relative to the vessel size might contribute to the angioscopically complete neointimal coverage after SES implantation. (J Am Coll Cardiol Intv 2009;2:989-94) (c) 2009 by the American College of Cardiology Foundation
引用
下载
收藏
页码:989 / 994
页数:6
相关论文
共 50 条
  • [31] FAVORABLE NEOINTIMAL COVERAGE IN EVEROLIMUS-ELUTING STENT AT 9 MONTHS AFTER STENT IMPLANTATION: COMPARISON WITH SIROLIMUS-ELUTING STENT USING OPTICAL COHERENCE TOMOGRAPHY
    Choi, Hyun Hee
    Yoon, Duck Hyoung
    Hong, Kyung Soon
    Kim, Jung-Sun
    Kim, Tae Hoon
    Kim, Byeong Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1732 - E1732
  • [32] Vascular response after overlapping sirolimus-eluting stent implantation: Serial intravascular ultrasound analysis
    Miyazawa, A
    Shimada, Y
    Waseda, K
    Yamasaki, M
    Ako, J
    Morino, Y
    Sudhir, K
    Honda, Y
    Yock, PG
    Fitzgerald, PJ
    CIRCULATION, 2005, 112 (17) : U834 - U834
  • [33] Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography
    Choi, Hyun Hee
    Kim, Jung-Sun
    Yoon, Duck Hyoung
    Hong, Kyung-Soon
    Kim, Tae Hoon
    Kim, Byeong Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (03): : 491 - 497
  • [34] Comparison of Neointimal Coverage of Sirolimus-Eluting Stent and Paclitaxel-Eluting stent using Optical Coherence Tomography at 9 Months After Implantation
    Kim, Jin-Sun
    Kim, Jung-Sun
    Park, Sang Min
    Kim, Won-Ho
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 32I - 32I
  • [35] Comparison of neointimal coverage of sirolimus-eluting stent and zotarolimus-eluting stent using optical coherence tomography at 9 months after implantation
    Kim, J. -S.
    Kim, J. -S.
    Ko, Y. -G.
    Choi, D.
    Jang, Y.
    Chung, N.
    Shim, W. -H.
    Cho, S. -Y.
    EUROPEAN HEART JOURNAL, 2008, 29 : 147 - 147
  • [36] Intravascular ultrasound assessment of lesions with target vessel failure after sirolimus-eluting stent implantation
    Takebayashi, H
    Kobayashi, Y
    Mintz, GS
    Carlier, SG
    Fujii, K
    Yasuda, T
    Moussa, I
    Mehran, R
    Dangas, GD
    Collins, MB
    Kreps, E
    Lansky, AJ
    Stone, GW
    Leon, MB
    Moses, JW
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (04): : 498 - 502
  • [37] TEMPORAL CHANGES OF NEOINTIMAL COVERAGE AND THROMBOGENICITY AFTER DRUG-ELUTING STENT IMPLANTATION; ANGIOSCOPIC COMPARISON BETWEEN SIROLIMUS-ELUTING AND PACLITAXELELUTING STENT
    Hara, Masahiko
    Nishino, Masami
    Masaki, Takeshi
    Mori, Naoki
    Yoshimura, Takahiro
    Lee, Yasuharu
    Nakamura, Daisuke
    Nakatani, Shinpei
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Yamaguchi, Hitoshi
    Tanouchi, Jun
    Yamada, Yoshio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [38] Serial intravascular ultrasound analysis of vascular remodeling at sites of incomplete stent apposition after sirolimus-eluting stent implantation
    Kimura, M
    Carlier, SG
    Mintz, GS
    Lui, J
    Costa, JD
    Sano, K
    Takebayashi, H
    Yasuda, T
    Fujii, K
    Mehran, R
    Dangas, G
    Stone, GW
    Moses, JW
    Leon, MB
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 171H - 172H
  • [39] Very late stent thrombosis after sirolimus-eluting stent implantation: Evaluation by intravascular ultrasound and optical coherence tomography
    Mabuchi T.
    Fujino S.
    Yamaguchi M.
    Noji Y.
    Ichise T.
    Aoyama T.
    Cardiovascular Intervention and Therapeutics, 2013, 28 (4) : 388 - 393
  • [40] Impact of asymmetric stent expansion on neointimal hyperplasia following sirolimus-eluting stent implantation
    Kaneda, H
    Ako, J
    Honda, Y
    Terashima, M
    Morino, Y
    Yock, PG
    Popma, JJ
    Leon, MB
    Moses, JW
    Fitzgerald, PJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (10): : 1404 - 1407