Optimal Stent-Sizing With Intravascular Ultrasound Contributes to Complete Neointimal Coverage After Sirolimus-Eluting Stent Implantation Assessed by Angioscopy

被引:17
|
作者
Sera, Fusako [2 ]
Awata, Masaki [2 ]
Uematsu, Masaaki [2 ]
Kotani, Jun-ichi [1 ]
Nanto, Shinsuke [1 ,2 ]
Nagata, Seiki [2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Adv Cardiovasc Therapeut, Suita, Osaka 5650871, Japan
[2] Kansai Rosai Hosp, Ctr Cardiovasc, Amagasaki, Hyogo, Japan
关键词
angioscopy; intravascular ultrasound; neointima; sirolimus-eluting stent; PALMAZ-SCHATZ STENTS; CORONARY-ARTERY; LATE THROMBOSIS; ANTIPLATELET THERAPY; MORPHOLOGIC CHANGES; RADIATION-THERAPY; CLINICAL-TRIALS; TIME-COURSE; RESTENOSIS; PREDICTORS;
D O I
10.1016/j.jcin.2009.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aim of this study was to explore the determinants of neointimal coverage after sirolimus-eluting stent (SES). Background Although SES has significantly reduced in-stent restenosis by inhibiting neointimal hyperplasia, insufficient neointimal coverage after stenting might result in adverse outcomes. Methods We evaluated 28 SES lesions with both angioscopy and intravascular ultrasound (IVUS). Quantitative assessments of the lesions and stent expansion were performed by IVUS at the time of stent implantation, and degree of neointimal coverage was judged by angioscopy at follow-up (11 +/- 6 months) whether the stent struts were embedded by the neointima ("complete/incomplete" neointimal coverage). Results "Complete" coverage was identified in 10 (36%), and "incomplete" coverage was identified in 18 (64%). Time from the stenting to angioscopy as well as the lesion and procedural characteristics were similar between the complete and incomplete coverage groups. The IVUS parameters were also similar, except for the final minimum stent cross-sectional area (CSA) (7.0 +/- 1.8 mm(2) in complete vs. 5.3 +/- 1.9 mm(2) in incomplete, p = 0.02) and lumen CSA at the distal reference site (6.1 +/- 1.4 mm(2) in complete vs. 4.9 +/- 1.2 mm(2) in incomplete, p = 0.02). The ratio of the stent area to the vessel area was significantly larger in the complete coverage than in the incomplete coverage group (0.52 +/- 0.11 vs. 0.39 +/- 0.09, p = 0.002). Conclusions Adequate stent sizing relative to the vessel size might contribute to the angioscopically complete neointimal coverage after SES implantation. (J Am Coll Cardiol Intv 2009;2:989-94) (c) 2009 by the American College of Cardiology Foundation
引用
下载
收藏
页码:989 / 994
页数:6
相关论文
共 50 条
  • [21] Impact of preinterventional lesion calcification on neointimal hyperplasia following sirolimus-eluting stent implantation: An intravascular ultrasound analysis
    Kaneda, H
    Koizumi, T
    Ako, J
    Honda, Y
    Terashima, M
    Shimada, Y
    Morino, Y
    Yock, PG
    Leon, MB
    Moses, JW
    Fitzgerald, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 67A - 67A
  • [22] Stent Expansion and Neointimal Hyperplasia after Sirolimus-eluting or Paclitaxel-eluting Stent Implantation in Diabetic Patients
    Egede, Rasmus
    Jensen, Lisette Okkels
    Mintz, Gary S.
    Maeng, Michael
    Christiansen, Evald Hoej
    Hansen, Knud Noerregaard
    Galloe, Anders
    Kelbaek, Henning
    Lassen, Jens Flensted
    Thuesen, Leif
    Thayssen, Per
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 203I - 203I
  • [23] Inflammation and vulnerability of culprit lesion may promote neointimal coverage after sirolimus-eluting stent implantation
    Nishino, Masami
    Nakatani, Shinpei
    Here, Masahiko
    Hashimoto, Akihito
    Yamagami, Kiyoshi
    Matsuoka, Ken
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Yamaguchi, Hitoshi
    Tanaka, Kenjiro
    Tanouchi, Jun
    Yamada, Yoshio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B4 - B4
  • [24] Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation
    Takano, Masamichi
    Inami, Shigenobu
    Jang, Ik-Kyung
    Yamamoto, Masanori
    Murakami, Daisuke
    Seimiya, Koji
    Ohba, Takayoshi
    Mizuno, Kyoichi
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08): : 1033 - 1038
  • [25] Late stent thrombosis after implantation of a sirolimus-eluting stent
    Kerner, A
    Gruberg, L
    Kapeliovich, M
    Grenadier, E
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (04) : 505 - 508
  • [26] Volumetric intravascular ultrasound assessment of neointimal hyperplasia and nonuniform stent strut distribution in sirolimus-eluting stent restenosis
    Sano, Koichi
    Mintz, Gary S.
    Carlier, Stephane G.
    Fujii, Kenichi
    Takebayashi, Hideo
    Kimura, Masashi
    Costa, Jose Ribamar, Jr.
    Tanaka, Kaoru
    Costa, Ricardo A.
    Lui, Joanna
    Weisz, Giora
    Moussa, Issam
    Dangas, George D.
    Mehran, Roxana
    Lansky, Alexandra J.
    Kreps, Edward M.
    Collins, Michael
    Stone, Gregg W.
    Moses, Jeffrey W.
    Leon, Martin B.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (12): : 1559 - 1562
  • [27] Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography
    Hyun Hee Choi
    Jung-Sun Kim
    Duck Hyoung Yoon
    Kyung-Soon Hong
    Tae Hoon Kim
    Byeong Keuk Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2012, 28 : 491 - 497
  • [28] FAVORABLE NEOINTIMAL COVERAGE IN EVEROLIMUS-ELUTING STENT AT 9 MONTH AFTER STENT IMPLANTATION: COMPARISON WITH SIROLIMUS-ELUTING STENT USING OPTICAL COHERENCE TOMOGRAPHY
    Choi, Hyun-Hee
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    Sim, Won-Heum
    Cho, Seung-Yun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [29] Stent thrombosis after successful sirolimus-eluting stent implantation
    Jeremias, A
    Sylvia, B
    Bridges, J
    Kirtane, AJ
    Bigelow, B
    Pinto, DS
    Ho, KKL
    Cohen, DJ
    Garcia, LA
    Cutlip, DE
    Carrozza, JP
    CIRCULATION, 2004, 109 (16) : 1930 - 1932
  • [30] Silent stent fracture after sirolimus-eluting stent implantation
    Ino, Yasushi
    Kubo, Takashi
    Takarada, Shigeho
    Tanimoto, Takashi
    Arida, Yu
    Kitabata, Hironori
    Kuroi, Akio
    Ueno, Satoshi
    Yomano, Takashi
    Ikejima, Hideyuki
    Tsujioka, Hiroto
    Ookouchi, Hirofumi
    Kashiwagi, Manabu
    Kataiwa, Hiderou
    Nakamura, Nobuo
    Tanaka, Atsushi
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 107L - 107L