Optimal Stent-Sizing With Intravascular Ultrasound Contributes to Complete Neointimal Coverage After Sirolimus-Eluting Stent Implantation Assessed by Angioscopy

被引:17
|
作者
Sera, Fusako [2 ]
Awata, Masaki [2 ]
Uematsu, Masaaki [2 ]
Kotani, Jun-ichi [1 ]
Nanto, Shinsuke [1 ,2 ]
Nagata, Seiki [2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Adv Cardiovasc Therapeut, Suita, Osaka 5650871, Japan
[2] Kansai Rosai Hosp, Ctr Cardiovasc, Amagasaki, Hyogo, Japan
关键词
angioscopy; intravascular ultrasound; neointima; sirolimus-eluting stent; PALMAZ-SCHATZ STENTS; CORONARY-ARTERY; LATE THROMBOSIS; ANTIPLATELET THERAPY; MORPHOLOGIC CHANGES; RADIATION-THERAPY; CLINICAL-TRIALS; TIME-COURSE; RESTENOSIS; PREDICTORS;
D O I
10.1016/j.jcin.2009.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aim of this study was to explore the determinants of neointimal coverage after sirolimus-eluting stent (SES). Background Although SES has significantly reduced in-stent restenosis by inhibiting neointimal hyperplasia, insufficient neointimal coverage after stenting might result in adverse outcomes. Methods We evaluated 28 SES lesions with both angioscopy and intravascular ultrasound (IVUS). Quantitative assessments of the lesions and stent expansion were performed by IVUS at the time of stent implantation, and degree of neointimal coverage was judged by angioscopy at follow-up (11 +/- 6 months) whether the stent struts were embedded by the neointima ("complete/incomplete" neointimal coverage). Results "Complete" coverage was identified in 10 (36%), and "incomplete" coverage was identified in 18 (64%). Time from the stenting to angioscopy as well as the lesion and procedural characteristics were similar between the complete and incomplete coverage groups. The IVUS parameters were also similar, except for the final minimum stent cross-sectional area (CSA) (7.0 +/- 1.8 mm(2) in complete vs. 5.3 +/- 1.9 mm(2) in incomplete, p = 0.02) and lumen CSA at the distal reference site (6.1 +/- 1.4 mm(2) in complete vs. 4.9 +/- 1.2 mm(2) in incomplete, p = 0.02). The ratio of the stent area to the vessel area was significantly larger in the complete coverage than in the incomplete coverage group (0.52 +/- 0.11 vs. 0.39 +/- 0.09, p = 0.002). Conclusions Adequate stent sizing relative to the vessel size might contribute to the angioscopically complete neointimal coverage after SES implantation. (J Am Coll Cardiol Intv 2009;2:989-94) (c) 2009 by the American College of Cardiology Foundation
引用
下载
收藏
页码:989 / 994
页数:6
相关论文
共 50 条
  • [1] Optimal expansion of the stent is a major contributor to the neointimal coverage following sirolimus-eluting stent implantation: A combined study of angioscopy and intravascular ultrasound
    Sera, Fusako
    Kotani, Jun-Ichi
    Awata, Masaki
    Nanto, Shinsuke
    Uematsu, Masaaki
    Morozumi, Takakazu
    Watanabe, Tetsuya
    Onishi, Toshinari
    Iida, Osamu
    Minamiguchi, Hitoshi
    Akahori, Hirokuni
    Yano, Masamichi
    Ikeoka, Kuniyasu
    Okamoto, Shin
    Tanaka, Nobuaki
    Yasui, Haruyo
    Nagata, Seiki
    CIRCULATION, 2007, 116 (16) : 616 - 616
  • [2] Intravascular Ultrasound Guidance may Modify Neointimal Coverage Following Sirolimus-Eluting Stent Implantation
    Sera, Fusako
    Uematsu, Masaaki
    Kotani, Jun-ichi
    Awata, Masaki
    Morozumi, Takakazu
    Watanabe, Tetsuya
    Onishi, Toshinari
    Iida, Osamu
    Minamiguchi, Hitoshi
    Kawamoto, Kenji
    Yano, Masamichi
    Ikeoka, Kuniyasu
    Okamoto, Shin
    Tanaka, Nobuaki
    Yasui, Haruyo
    Ishihara, Takayuki
    Dohi, Tomoharu
    Nanto, Shinsuke
    Nagata, Seiki
    CIRCULATION, 2008, 118 (18) : S748 - S748
  • [3] Serial long-term evaluation of neointimal stent coverage and thrombus after sirolimus-eluting stent implantation by use of coronary angioscopy
    Takano, Masamichi
    Yamamoto, Masanori
    Xie, Yong
    Murakami, Daisuke
    Inami, Shigenobu
    Okamatsu, Kentaro
    Seimiya, Koji
    Ohba, Takayoshi
    Seino, Yoshihiko
    Mizuno, Kyoichi
    HEART, 2007, 93 (11) : 1353 - 1356
  • [4] Serial long-term evaluation of neointimal stent coverage and thrombus after sirolimus-eluting stent implantation by use of coronary angioscopy
    Takano, Masamichi
    Yamamoto, Masanori
    Xie, Yong
    Murakami, Daisuke
    Inami, Shigenobu
    Okamatsu, Kentaro
    Seimiya, Koji
    Ohba, Takayoshi
    Seino, Yoshihiko
    Mizuno, Kyoichi
    HEART, 2007, 93 (12) : 1533 - 1536
  • [5] Impact of intravascular ultrasound lesion characteristics on neointimal hyperplasia following sirolimus-eluting stent implantation
    Kaneda, H
    Koizumi, T
    Ako, J
    Terashima, M
    Morino, Y
    Honda, Y
    Yock, PG
    Leon, MB
    Moses, JW
    Fitzgerald, PJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (09): : 1237 - 1241
  • [6] Influence of Strut Width on Neointimal Coverage After Sirolimus-Eluting Stent Implantation Assessed by Optical Coherence Tomography
    Nakatani, Shimpei
    CIRCULATION, 2009, 120 (18) : S947 - S947
  • [7] Distribution pattern of neointimal hyperplasia following sirolimus-eluting stent implantation assessed by 3-dimensional intravascular ultrasound
    Kaneda, Hideaki
    Ako, Junya
    Terashima, Mitsuyasu
    Waseda, Katsuhisa
    Yock, Paul G.
    Fitzgerald, Peter J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 135 (02) : 243 - 245
  • [8] Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation
    Awata, Masaki
    Kotani, Jun-ichi
    Uematsu, Masaaki
    Morozumi, Takakazu
    Watanabe, Tetsuya
    Onishi, Toshinari
    Iida, Osamu
    Sera, Fusako
    Nanto, Shinsuke
    Hori, Masatsugu
    Nagata, Seiki
    CIRCULATION, 2007, 116 (08) : 910 - 916
  • [9] Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation
    Hong, Myeong-Ki
    Mintz, Gary S.
    Lee, Cheol Whan
    Park, Duk-Woo
    Choi, Bong-Ryong
    Park, Kyoung-Ha
    Kim, Young-Hak
    Cheong, Sang-Sig
    Song, Jae-Kwan
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    EUROPEAN HEART JOURNAL, 2006, 27 (11) : 1305 - 1310
  • [10] Impact of asymmetric stent expansion on neointimal hyperplasia after sirolimus-eluting stent implantation
    Kaneda, H
    Ako, J
    Honda, Y
    Sakurai, R
    Terashima, M
    Sonoda, S
    Shimada, Y
    Morino, Y
    Yock, PG
    Leon, MB
    Moses, JW
    Fitzgerald, PJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 187L - 187L