Prospective evaluation of changes in anterior segment morphology after laser iridotomy in Chinese eyes by rotating Scheimpflug camera imaging

被引:31
|
作者
Li, Shuning [1 ]
Wang, Hongtao [1 ]
Mu, Dapeng [1 ]
Fu, Jing [1 ]
Wang, Xiaozhen [1 ]
Wang, Jian [1 ]
Wang, Ningli [1 ]
机构
[1] Capital Med Univ, Beijing Ophthalmol & Visual Sci Lab, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing, Peoples R China
来源
关键词
LPI; PACS; PAC; rotating Scheimpflug camera imaging; 3-D morphology; ANGLE-CLOSURE GLAUCOMA; PERIPHERAL IRIDOTOMY;
D O I
10.1111/j.1442-9071.2010.02205.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
P>Background: To investigate the 3-D morphology changes of anterior segment in primary angle-closure suspect and primary angle-closure after laser peripheral iridotomy (LPI) using rotating Scheimpflug camera. Methods: A total of 37 eyes of 25 patients were enrolled in the study. Just before and after LPI, rotating Scheimpflug camera was performed on each selected eye by one skilled ophthalmologist. Comparison of anterior segment parameters before and after LPI such as central corneal thickness, central anterior chamber depth, peripheral anterior chamber depth, anterior chamber volume, pupil diameter and anterior chamber angle of cross-section photographs from 0 degrees to 180 degrees (ACA) were analysed. Results: Before and after LPI, central corneal thickness increased from 537.92 +/- 27.92 mu m to 541.49 +/- 27.85 mu m (P = 0.074); no statistic changes of central anterior chamber depth were found before LPI (1.72 +/- 0.27 mm) and after LPI (1.70 +/- 0.24 mm) (P = 0.337); peripheral anterior chamber depth deepen from 0.89 +/- 0.26 to 1.14 +/- 0.26 mm (P = 0.000); anterior chamber volume increased from 55.54 +/- 14.25 to 82.65 +/- 17.63 mm3 (P = 0.000); average pupil diameter of all patients are 1.72 +/- 0.42 and 1.63 +/- 0.46 mm, respectively, showed no statistic difference (P = 0.228). ACA widen from 25.51 +/- 5.66 degrees to 28.11 +/- 5.67 degrees in 9 o'clock direction(P = 0.005), and from 25.77 +/- 5.15 degrees to 27.91 +/- 4.87 degrees in 3 o'clock direction after LPI (P = 0.020). Conclusion: LPI induce dramatic changes of 3-D anterior segment morphology in primary angle-closure suspect and primary angle-closure.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [31] Changes in Anterior Segment Morphology of Iris Bombe before and after Laser Peripheral Iridotomy in Patients with Uveitic Secondary Glaucoma
    Ikegawa, Wakako
    Suzuki, Takashi
    Namiguchi, Koji
    Mizoue, Shiro
    Shiraishi, Atsushi
    Ohashi, Yuichi
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [32] Morphological changes of the anterior segment after laser peripheral iridotomy in primary angle closure
    Lei, K.
    Wang, N.
    Wang, L.
    Wang, B.
    EYE, 2009, 23 (02) : 345 - 350
  • [33] Effect of laser peripheral iridotomy on angle configuration in eyes with angle closure: An evaluation by the anterior segment OCT
    See, JLS
    Chew, PTK
    Nolan, WP
    Zheng, C
    Sunita, R
    Smith, S
    Friedman, D
    Aung, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [34] Anterior Chamber Morphology Before and After Laser Peripheral Iridotomy Determined by Scheimpflug Technology in White Patients With Narrow Angles
    Vryonis, Nikolaos
    Nikita, Eleni
    Vergados, Ioannis
    Theodossiadis, Panagiotis
    Filippopoulos, Theodoros
    JOURNAL OF GLAUCOMA, 2013, 22 (09) : 679 - 683
  • [35] Comparison of ultrasound biomicroscopy and spectraldomain anterior segment optical coherence tomography in evaluation of anterior segment after laser peripheral iridotomy
    Xiao-Yun Ma
    Dan Zhu
    Jun Zou
    Wen-Jie Zhang
    Yi-Lin Cao
    International Journal of Ophthalmology, 2016, 9 (03) : 417 - 423
  • [36] Comparing the Effect of Laser Peripheral Iridotomy to Lens Extraction on Anterior Segment Morphology in Narrow Angle Eyes using Anterior Segment Optical Coherence Tomography (ASOCT)
    Gross, Jacob
    Baker, Laura
    Chuang, Alice
    Blieden, Lauren S.
    Bell, Nicholas P.
    Feldman, Robert M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [37] Comparison of ultrasound biomicroscopy and spectral-domain anterior segment optical coherence tomography in evaluation of anterior segment after laser peripheral iridotomy
    Ma, Xiao-Yun
    Zhu, Dan
    Zou, Jun
    Zhang, Wen-Jie
    Cao, Yi-Lin
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (03) : 417 - 423
  • [38] Anterior segment changes after femtosecond cataract surgery measured with optical coherence tomography and scheimpflug imaging technology
    Carrasco, M. J. Perez
    Fernandez-Cuenca, S.
    Lorente-Hevia, M. P.
    de Rementeria, L. Alvarez
    Aldaham, S.
    Puell, M.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [39] Changes in Anterior Segment Morphology and Intraocular Pressure after Cataract Surgery in Non-glaucomatous Eyes
    Giglio, Rosa
    Inferrera, Leandro
    De Giacinto, Chiara
    D'Aloisio, Rossella
    Beccastrini, Andrea
    Vinciguerra, Alex Lucia
    Perrotta, Alberto Armando
    Toro, Mario Damiano
    Zweifel, Sandrine
    Tognetto, Daniele
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2023, 240 (04) : 449 - 455
  • [40] Quantitative evaluation of changes in anterior segment biometry by peripheral laser iridotomy using newly developed scanning peripheral anterior chamber depth analyser
    Kashiwagi, K
    Abe, K
    Tsukahara, S
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (08) : 1036 - 1041