Prospective evaluation of changes in anterior segment morphology after laser iridotomy in Chinese eyes by rotating Scheimpflug camera imaging

被引:31
|
作者
Li, Shuning [1 ]
Wang, Hongtao [1 ]
Mu, Dapeng [1 ]
Fu, Jing [1 ]
Wang, Xiaozhen [1 ]
Wang, Jian [1 ]
Wang, Ningli [1 ]
机构
[1] Capital Med Univ, Beijing Ophthalmol & Visual Sci Lab, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing, Peoples R China
来源
关键词
LPI; PACS; PAC; rotating Scheimpflug camera imaging; 3-D morphology; ANGLE-CLOSURE GLAUCOMA; PERIPHERAL IRIDOTOMY;
D O I
10.1111/j.1442-9071.2010.02205.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
P>Background: To investigate the 3-D morphology changes of anterior segment in primary angle-closure suspect and primary angle-closure after laser peripheral iridotomy (LPI) using rotating Scheimpflug camera. Methods: A total of 37 eyes of 25 patients were enrolled in the study. Just before and after LPI, rotating Scheimpflug camera was performed on each selected eye by one skilled ophthalmologist. Comparison of anterior segment parameters before and after LPI such as central corneal thickness, central anterior chamber depth, peripheral anterior chamber depth, anterior chamber volume, pupil diameter and anterior chamber angle of cross-section photographs from 0 degrees to 180 degrees (ACA) were analysed. Results: Before and after LPI, central corneal thickness increased from 537.92 +/- 27.92 mu m to 541.49 +/- 27.85 mu m (P = 0.074); no statistic changes of central anterior chamber depth were found before LPI (1.72 +/- 0.27 mm) and after LPI (1.70 +/- 0.24 mm) (P = 0.337); peripheral anterior chamber depth deepen from 0.89 +/- 0.26 to 1.14 +/- 0.26 mm (P = 0.000); anterior chamber volume increased from 55.54 +/- 14.25 to 82.65 +/- 17.63 mm3 (P = 0.000); average pupil diameter of all patients are 1.72 +/- 0.42 and 1.63 +/- 0.46 mm, respectively, showed no statistic difference (P = 0.228). ACA widen from 25.51 +/- 5.66 degrees to 28.11 +/- 5.67 degrees in 9 o'clock direction(P = 0.005), and from 25.77 +/- 5.15 degrees to 27.91 +/- 4.87 degrees in 3 o'clock direction after LPI (P = 0.020). Conclusion: LPI induce dramatic changes of 3-D anterior segment morphology in primary angle-closure suspect and primary angle-closure.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [21] Comparison of anterior segment changes after femtosecond laser LASIK and SMILE using a dual rotating Scheimpflug analyzer
    Kim, Bu Ki
    Mun, Su Joung
    Yang, Young Hoon
    Kim, Ji Sun
    Moon, Jun Hyung
    Chung, Young Taek
    BMC OPHTHALMOLOGY, 2019, 19 (01)
  • [22] Structural analysis of the anterior chamber using a rotating scheimpflug camera in eyes undergoing laser in situ Keratomileusis
    Nishimura, R
    Negishi, K
    Saiki, M
    Shimizu, S
    Kurosaka, D
    Tsubota, K
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [23] Changes in Anterior Segment Parameters After Laser Peripheral Iridotomy in Caucasian Eyes With Different Primary Angle Closure Mechanisms
    Tun, Tin A.
    Sawicki, Andrzej
    Wilkos-Kuc, Agnieszka
    Aung, Tin
    Zarnowski, Tomasz
    JOURNAL OF GLAUCOMA, 2023, 32 (10) : 820 - 825
  • [24] Evaluation of changes in anterior segment morphology using Sirius Scheimpflug-Placido disk topographer following laser peripheral iridotomy in primary angle-closure disease
    Stephen, Mary
    Kaliaperumal, Subashini
    Behera, Geeta
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (03) : 848 - +
  • [25] Circumferential Assessment of Changes in Anterior Segment Characteristics and Baseline Predictors of Angle Widening After Laser Iridotomy in Caucasian Eyes
    Tun, Tin A.
    Sawicki, Andrzej
    Wilkos-Kuc, Agnieszka
    Aung, Tin
    Zarnowski, Tomasz
    JOURNAL OF GLAUCOMA, 2021, 30 (09) : 839 - 845
  • [26] Anterior segment optical coherence tomography for imaging the anterior chamber after laser peripheral iridotomy
    Memarzadeh, Farnaz
    Li, Yan
    Chopra, Vikas
    Varma, Rohit
    Francis, Brian A.
    Huang, David
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (05) : 877 - 879
  • [27] Quantitative evaluation of anterior chamber changes after iridotomy using Pentacam anterior segment analyzer
    Lopez-Caballero, Cristina
    Puerto-Hernandez, Beatriz
    Munoz-Negrete, Francisco J.
    Rebolleda, Gema
    Contreras, Ines
    Cabarga, Carmen
    Corral, Angeles
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (02) : 327 - 332
  • [28] Changes in anterior segment morphology of iris bombe before and after laser peripheral iridotomy in patients with uveitic secondary glaucoma
    Ikegawa, Wakako
    Suzuki, Takashi
    Mizoue, Shiro
    Ohashi, Yuichi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [29] Morphological changes of the anterior segment after laser peripheral iridotomy in primary angle closure
    K Lei
    N Wang
    L Wang
    B Wang
    Eye, 2009, 23 : 345 - 350
  • [30] Longitudinal Changes in Anterior Segment Parameters After Laser Peripheral Iridotomy Assessed by Anterior Segment Optical Coherence Tomography
    Lee, Kyoung Sub
    Sung, Kyung Rim
    Shon, Kilhwan
    Sun, Jae Hong
    Lee, Jong Rak
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3166 - 3170