Biomechanical and Mechanostat analysis of a titanium layered porous implant for mandibular reconstruction: The effect of the topology optimization design

被引:24
|
作者
Peng, Wen-ming [1 ,2 ,3 ]
Cheng, Kang-jie [1 ,2 ,3 ]
Liu, Yun-feng [1 ,2 ,3 ]
Nizza, Mark [4 ]
Baur, Dale A. [4 ]
Jiang, Xian-feng [1 ,2 ,3 ]
Dong, Xing-tao [1 ,2 ,3 ]
机构
[1] Zhejiang Univ Technol, Coll Mech Engn, Hangzhou 310023, Peoples R China
[2] Zhejiang Univ Technol, Key Lab Special Purpose Equipment & Adv Proc Tech, Minist Educ & Zhejiang Prov, Hangzhou 310023, Peoples R China
[3] Zhejiang Univ Technol, Natl Int Joint Res Ctr Special Purpose Equipment, Hangzhou 310023, Peoples R China
[4] Case Western Reserve Univ, Sch Dent Med, Dept Oral & Maxillofacial Surg, Cleveland, OH 44106 USA
基金
中国国家自然科学基金;
关键词
Mandibular reconstruction; Titanium layered porous implant; Topology optimum design; Finite element analysis; Mechanostat evaluation; FINITE-ELEMENT-ANALYSIS; MECHANICAL-PROPERTIES; MODULAR ENDOPROSTHESIS; FIXATION; SCAFFOLD; BIOMATERIALS; GEOMETRY; REPAIR; PLATES; FLAP;
D O I
10.1016/j.msec.2021.112056
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A porous scaffold/implant is considered a potential method to repair bone defects, but its mechanical stability and biomechanics during the repair process are not yet clear. A mandibular titanium implant was proposed and designed with layered porous structures similar to that of the bone tissue, both in structure and mechanical properties. Topology was used to optimize the design of the porous implant and fixed structure. The finite element analysis was combined with bone ?Mechanostat? theory to evaluate the stress and osteogenic property of the layered porous implant with 3 different fixation layouts (Model I with 4 screws, Model II with 5 screws and Model III with 6 screws) for mandibular reconstruction. The results showed that Model III could effectively reduce the stress shielding effect, stress within the optimized implant, defective mandible, and screws were respectively dropped 48.18%, 44.23%, and 57.27% compared to Model I, and the porous implant had a significant stress transmission effect and maintained the same stress distribution as the intact mandible after the mandibular defect was repaired. The porous implant also showed a significant mechanical stimulation effect on the growth and healing of the bone tissue according to the bone ?Mechanostat? theory. The combination of porous structure with the topology technique is a promising option to improve the mechanical stability and osteogenesis of the implant, and could provide a new solution for mandibular reconstruction.
引用
收藏
页数:13
相关论文
共 46 条
  • [21] A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus
    Merema, Bram B. J.
    Spijkervet, Frederik K. L.
    Kraeima, Joep
    Witjes, Max J. H.
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [22] The feasibility of a custom-made endoprosthesis in mandibular reconstruction: Implant design and finite element analysis
    Pinheiro, Manuel
    Alves, J. L.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (10) : 2116 - 2128
  • [23] Biomechanical effect of implant design on four implants supporting mandibular full-arch fixed dentures: In vitro test and finite element analysis
    Wu, Aaron Yu-Jen
    Hsu, Jui-Ting
    Fuh, Lih-Jyh
    Huang, Heng-Li
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2020, 119 (10) : 1514 - 1523
  • [24] Topology optimization design for buckling analysis related to the size effect
    Gan, Ning
    Wang, Qianxuan
    MATHEMATICS AND MECHANICS OF SOLIDS, 2022, 27 (07) : 1301 - 1318
  • [25] Design, analysis and optimization of porous titanium alloys scaffolds by using additive manufacture
    Yang, Xue
    Song, Xiujuan
    Zhang, Guoliang
    Xu, Shubo
    Wang, Wenming
    Sun, Kangwei
    Ma, Xiquan
    Sun, Siyu
    Pan, Yuefei
    Li, Jianing
    Ren, Guocheng
    Zhang, Weihai
    International Journal for Simulation and Multidisciplinary Design Optimization, 2024, 15
  • [26] Structural Design and Finite Element Simulation Analysis of Grade 3 Graded Porous Titanium Implant
    Liu, Bowen
    Xu, Wei
    Chen, Mingying
    Chen, Dongdong
    Sun, Guyu
    Zhang, Ce
    Pan, Yu
    Lu, Jinchao
    Guo, Enbo
    Lu, Xin
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (17)
  • [27] Analysis of biomechanical behavior of 3D printed mandibular graft with porous scaffold structure designed by topological optimization
    Jiajie Hu
    Joanne H. Wang
    Russel Wang
    Xiong Bill Yu
    Yunfeng Liu
    Dale A. Baur
    3D Printing in Medicine, 5
  • [28] Analysis of biomechanical behavior of 3D printed mandibular graft with porous scaffold structure designed by topological optimization
    Hu, Jiajie
    Wang, Joanne H.
    Wang, Russel
    Yu, Xiong Bill
    Liu, Yunfeng
    Baur, Dale A.
    3D PRINTING IN MEDICINE, 2019, 5 (01)
  • [29] Effect of Porous Microstructures on the Biomechanical Characteristics of a Root Analogue Implant: An Animal Study and a Finite Element Analysis
    Liu, Ting
    Chen, Yu
    Apicella, Antonio
    Mu, Zhixiang
    Yu, Ti
    Huang, Yuanding
    Wang, Chao
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2020, 6 (11): : 6356 - 6367
  • [30] Biomechanical effect of implant design on four implants supporting mandibular full-arch fixed dentures: in vitro test and finite element analysis (vol 119, pg 1514, 2020)
    Wu, Aaron Yu-Jen
    Hsu, Jui-Ting
    Fuh, Lih-Jyh
    Huang, Heng-Li
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2021, 120 (01) : 567 - 567