A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus

被引:0
|
作者
Merema, Bram B. J. [1 ]
Spijkervet, Frederik K. L. [1 ]
Kraeima, Joep [1 ]
Witjes, Max J. H. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Oral & Maxillofacial Surg, Hanzepl 1,POB 30 001, NL-9700 RB Groningen, Netherlands
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
BIOMECHANICAL EVALUATION; PLATE; MECHANOSTAT; BEHAVIOR; FRACTURE; SYSTEM; JOINT;
D O I
10.1038/s41598-024-82964-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy). To address these issues, in this study we explore, develop and validate a non-metallic solution: a topology-optimized polyetheretherketone (PEEK) load-bearing implant for large non-grafted mandibular continuity defects. In order to thoroughly validate the developed PEEK reconstruction, a dedicated MANDYBILATOR testing apparatus was developed. Using the MANDYBILATOR finite element analysis results of the implant were confirmed and the PEEK implant was mechanically validated for both static and dynamic loading. Results show that the PEEK reconstructed mandible is comparably strong as the unreconstructed mandible and is unlikely to fail due to fatigue. Our PEEK implant design has the mechanical potential to act as a substitute for the current titanium plates used in the reconstruction of continuity defects of the mandible. This may potentially lead to optimised patient-specific reconstructions, with the implants matching the bone's stiffness and possessing radiolucent properties which are useful for radiographic follow-ups and radiotherapy. Furthermore, the addition of the dynamic/cyclic MANDYBILATOR apparatus allows for more realistic application of the in-vivo loading of the mandible and can provide added insights in biomechanical behaviour of the mandible.
引用
收藏
页数:14
相关论文
共 4 条
  • [1] Design Criteria for Patient-specific Mandibular Continuity Defect Reconstructed Implant with Lightweight Structure using Weighted Topology Optimization and Validated with Biomechanical Fatigue Testing
    Lin, Chun-Li
    Wang, Yu-Tzu
    Chang, Chun-Ming
    Wu, Cheng-Hsien
    Tsai, Wei-Heng
    INTERNATIONAL JOURNAL OF BIOPRINTING, 2022, 8 (01)
  • [2] Computer-assisted Secondary Reconstruction of Mandibular Continuity Defects Using Non-Vascularized Iliac Crest Bone Graft Following Oral Cancer Resection
    Kanno, Takahiro
    Karino, Masaaki
    Yoshino, Aya
    Koike, Takashi
    Tatsumi, Hiroto
    Tsunematsu, Koji
    Nariai, Yoshiki
    Ide, Taichi
    Bai, Yunpeng
    Quang Ngoc Dong
    Sekine, Joji
    JOURNAL OF HARD TISSUE BIOLOGY, 2017, 26 (04) : 386 - 392
  • [3] Esthetic and functional reconstruction of large mandibular defects using free fibula flap and implant-retained prosthetics - a case series with long-term follow-up
    Tamás Sass
    József Piffkó
    Gábor Braunitzer
    Ferenc Oberna
    Head & Face Medicine, 17
  • [4] Esthetic and functional reconstruction of large mandibular defects using free fibula flap and implant-retained prosthetics-a case series with long-term follow-up
    Sass, Tamas
    Piffko, Jozsef
    Braunitzer, Gabor
    Oberna, Ferenc
    HEAD & FACE MEDICINE, 2021, 17 (01)