Detection and Evaluation on the Accuracy of Fiducial Tracking with Spine Auxiliary Positioning during IGRT Treatment

被引:0
|
作者
Li Yu [1 ]
Xu Hui-jun [1 ]
Zhang Su-jing [1 ]
机构
[1] 302 Mil Hosp, Oncol Radiotherapy Ctr, Beijing 100039, Peoples R China
关键词
IGRT; Spine; Fiducial; Accuracy; STEREOTACTIC RADIOSURGERY; TUMOR TRACKING; CYBERKNIFE; MARKERS; SYSTEM;
D O I
暂无
中图分类号
R-058 [];
学科分类号
摘要
With spine auxiliary positioning during IGRT treatment, utilize the simulated human phantom and dynamic lung phantom to detect the accuracy of fiducial tracking, and evaluate the value of it. Utilize CT to scan the phantoms which contain films, and design plans for phantoms and spine auxiliary positioning which use 1, 2, 3, 4, 5 and 6 fiducials for tracking, respectively. Each phantom plan shall be repeatedly implemented 3 times. The E2E software is used to analyze the accuracy of irradiation and then the average value is acquired. The results of detecting the simulated human phantom: the accuracy of irradiation with 1 and 2 fiducials for tracking (combining with spine auxiliary positioning) was 1.11 mm and 1.05 mm; with 3, 4, 5 and 6 fiducials, the accuracy was 1.07 mm, 0.92 mm, 0.97 mm and 1.15 mm, respectively. The results of detecting dynamic lung phantom: with 1 and 2 fiducials used for tracking (combining with spine auxiliary positioning), the accuracy of irradiation was 1.03 mm and 0.70 mm; with 3, 4, 5 and 6 fiducials, the accuracy was 0.58 mm, 1.02 mm, 0.65 mm and 0.96 mm, respectively. For the relatively static tumor or moving tumor, if the rotation direction of tumor is consistent with spine, the accuracy of using 1 or 2 fiducials for tracking was the same as using 3 to 6 fiducials. When the number of fiducials is not enough, fiducial tracking along with spine auxiliary positioning can well solve this problem.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [1] Detection and Evaluation on the Spine Tracking Accuracy During Image-guided Radiation Therapy
    Li Yu
    Xu Hui-jun
    Zhang Su-jing
    Yang Xiao
    2015 SEVENTH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2015), 2015, : 374 - 376
  • [2] TRACKING ACCURACY OF A REAL-TIME FIDUCIAL TRACKING SYSTEM FOR PATIENT POSITIONING AND MONITORING IN RADIATION THERAPY
    Shchory, Tal
    Schifter, Dan
    Lichtman, Rinat
    Neustadter, David
    Corn, Benjamin W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (04): : 1227 - 1234
  • [3] Clinical Data Evaluation of Fiducial-Free Spine Tracking for CyberKnife Radiosurgery
    Fu, D.
    Zhang, H.
    Wang, H.
    Wang, B.
    Kuduvalli, G.
    Maurer, C. R., Jr.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [4] Evaluation of CyberKnife (R) Fiducial Tracking Limitations to Assist Targeting Accuracy: A Phantom Study with Fiducial Displacement
    Goldsmith, Christy
    Green, Melanie M.
    Middleton, Brownwyn
    Cowley, Ian
    Robinson, Andrew
    Plowman, Nicholas P.
    Price, Patricia M.
    CUREUS, 2018, 10 (10):
  • [5] Evaluation of MEMS Sensors Accuracy for Bicycle Tracking and Positioning
    Miah, Shahjahan
    Kaparias, Ioannis
    Liatsis, Panos
    2015 INTERNATIONAL CONFERENCE ON SYSTEMS, SIGNALS AND IMAGE PROCESSING (IWSSIP 2015), 2015, : 299 - 303
  • [6] Electromagnetic target positioning and tracking during treatment
    Hoogeman, M.
    Ahmad, R.
    de Pree, I.
    Quint, S.
    Mens, J.
    Heijmen, B.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S105 - S105
  • [7] Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy
    Azcona, Juan Diego
    Li, Ruijiang
    Mok, Edward
    Hancock, Steven
    Xing, Lei
    MEDICAL PHYSICS, 2013, 40 (03)
  • [8] Verification of Methods for Positioning HNO Brain tumor patients during IGRT Treatment using kV Imaging devices
    Hindel, S.
    Sauerwein, W.
    Poettgen, C.
    Stuschke, M.
    Luedemann, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 158 - 158
  • [9] RADIATION EXPOSURE OF THE PATIENT DURING THE POSITIONING AND TRACKING PROCEDURES AT TREATMENT WITH THE CYBERKNIFE SYSTEM
    Aslamova, L.
    Luchkovskyi, S.
    Kulich, I.
    Melenevska, N.
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 144 - 146
  • [10] Development of semi-automatic procedure for detection and tracking of fiducial markers for orofacial kinematics during natural feeding
    Bunyak, Filiz
    Shiraishi, Naru
    Palaniappan, Kannappan
    Lever, Teresa E.
    Avivi-Arber, Limor
    Takahashi, Kazutaka
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 580 - 583