Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy

被引:21
|
作者
Azcona, Juan Diego [1 ,2 ]
Li, Ruijiang [1 ]
Mok, Edward [1 ]
Hancock, Steven [1 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Univ Navarra Clin, Div Radiat Phys, Dept Oncol, Navarra 31008, Spain
基金
美国国家卫生研究院;
关键词
image-guided radiation therapy; real-time tumor tracking; MV imaging; VMAT; intrafraction motion; INTERNAL MARKER TRACKING; REAL-TIME; GUIDED RADIOTHERAPY; KV; MV; ALGORITHM; MOTION; FEASIBILITY;
D O I
10.1118/1.4791646
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Real-time tracking of implanted fiducials in cine megavoltage (MV) imaging during volumetric modulated arc therapy (VMAT) delivery is complicated due to the inherent low contrast of MV images and potential blockage of dynamic leaves configurations. The purpose of this work is to develop a clinically practical autodetection algorithm for motion management during VMAT. Methods: The expected field-specific segments and the planned fiducial position from the Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system were projected onto the MV images. The fiducials were enhanced by applying a Laplacian of Gaussian filter in the spatial domain for each image, with a blob-shaped object as the impulse response. The search of implanted fiducials was then performed on a region of interest centered on the projection of the fiducial when it was within an open field including the case when it was close to the field edge or partially occluded by the leaves. A universal template formula was proposed for template matching and normalized cross correlation was employed for its simplicity and computational efficiency. The search region for every image was adaptively updated through a prediction model that employed the 3D position of the fiducial estimated from the localized positions in previous images. This prediction model allowed the actual fiducial position to be tracked dynamically and was used to initialize the search region. The artifacts caused by electronic interference during the acquisition were effectively removed. A score map was computed by combining both morphological information and image intensity. The pixel location with the highest score was selected as the detected fiducial position. The sets of cine MV images taken during treatment were analyzed with in-house developed software written in MATLAB (The Mathworks, Inc., Natick, MA). Five prostate patients were analyzed to assess the algorithm performance by measuring their positioning accuracy during treatment. Results: The algorithm was able to accurately localize the fiducial position on MV images with success rates of more than 90% per case. The percentage of images in which each fiducial was localized in the studied cases varied between 23% and 65%, with at least one fiducial having been localized between 40% and 95% of the images. This depended mainly on the modulation of the plan and fiducial blockage. The prostate movement in the presented cases varied between 0.8 and 3.5 mm (mean values). The maximum displacement detected among all patients was of 5.7 mm. Conclusions: An algorithm for automatic detection of fiducial markers in cine MV images has been developed and tested with five clinical cases. Despite the challenges posed by complex beam aperture shapes, fiducial localization close to the field edge, partial occlusion of fiducials, fast leaf and gantry movement, and inherently low MV image quality, good localization results were achieved in patient images. This work provides a technique for enabling real-time accurate fiducial detection and tumor tracking during VMAT treatments without the use of extra imaging dose. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4791646]
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Optimizing Fiducial Visibility On Periodically Acquired Megavoltage and Kilovoltage Image Pairs During Volumetric Modulated Arc Therapy
    Zhang, P.
    Wang, P.
    Laura, H.
    Ravindranath, B.
    Mageras, G.
    Hunt, M.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3195 - 3195
  • [2] Optimizing fiducial visibility on periodically acquired megavoltage and kilovoltage image pairs during prostate volumetric modulated arc therapy
    Zhang, Pengpeng
    Happersett, Laura
    Ravindranath, Bosky
    Zelefsky, Michael
    Mageras, Gig
    Hunt, Margie
    [J]. MEDICAL PHYSICS, 2016, 43 (05) : 2024 - 2029
  • [3] Clinical Feasibility Evaluation of Real-Time Tumor-Tracking Volumetric Modulated Arc Therapy (RT-VMAT)
    Miyamoto, N.
    Suzuki, R.
    Tanaka, S.
    Tamura, M.
    Tomioka, S.
    Taguchi, H.
    Katoh, N.
    Onimaru, R.
    Shimizu, S.
    Shirato, H.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E332 - E332
  • [4] Diaphragm Tracking System That Superimposes Planned Diaphragm Contours on Kilovolt Cine Images During Multiple Breath-Hold Volumetric Modulated Arc Therapy for Abdominal Tumors
    Nozawa, Yuki
    Ohta, Takeshi
    Katano, Atsuto
    Yamashita, Hideomi
    Nakagawa, Keiichi
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [5] Developing a MLC modifier program to improve fiducial detection for MV/kV imaging during hypofractionated prostate volumetric modulated arc therapy
    Happersett, Laura
    Wang, Ping
    Zhang, Pengpeng
    Mechalakos, James
    Li, Guang
    Eley, Eleanor
    Zelefsky, Michael
    Mageras, Gig
    Damato, Antonio L.
    Hunt, Margie
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 120 - 124
  • [6] Clinical application of real-time tumor-tracking for stereotactic volumetric modulated arc therapy for liver tumors
    Miyamoto, Naoki
    Katoh, Norio
    Kanehira, Takahiro
    Yokokawa, Kohei
    Suzuki, Ryusuke
    Uchinami, Yusuke
    Taguchi, Hiroshi
    Abo, Daisuke
    Aoyama, Hidefumi
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [7] Total Marrow Irradiation: A Clinical Evaluation of a Volumetric Modulated Arc Therapy Technique
    Cozzi, L.
    Mancosu, P.
    Navarria, P.
    Nicolini, G.
    Vanetti, E.
    Clivio, A.
    Fogliata, A.
    Ibatici, A.
    Santoro, A.
    Scorsetti, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S93 - S93
  • [8] Dosimetric Evaluation of Gated Volumetric Modulated Arc Radiation Therapy (VMAT) and Tumor-Tracking Robotic Radiation Therapy for Hepatocellular Carcinoma
    Yoon, K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E629 - E629
  • [9] Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device
    Diego Azcona, Juan
    Li, Ruijiang
    Mok, Edward
    Hancock, Steven
    Xing, Lei
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (04): : 762 - 768
  • [10] A Novel Approach to Tracking Intrafraction Prostate Motion during Volumetric Modulated Arc Therapy with Tomosynthesis
    Zhou, J.
    Turian, J.
    Lee, E.
    Templeton, A.
    Liao, Y.
    Chu, J.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)