Detection and Evaluation on the Accuracy of Fiducial Tracking with Spine Auxiliary Positioning during IGRT Treatment

被引:0
|
作者
Li Yu [1 ]
Xu Hui-jun [1 ]
Zhang Su-jing [1 ]
机构
[1] 302 Mil Hosp, Oncol Radiotherapy Ctr, Beijing 100039, Peoples R China
关键词
IGRT; Spine; Fiducial; Accuracy; STEREOTACTIC RADIOSURGERY; TUMOR TRACKING; CYBERKNIFE; MARKERS; SYSTEM;
D O I
暂无
中图分类号
R-058 [];
学科分类号
摘要
With spine auxiliary positioning during IGRT treatment, utilize the simulated human phantom and dynamic lung phantom to detect the accuracy of fiducial tracking, and evaluate the value of it. Utilize CT to scan the phantoms which contain films, and design plans for phantoms and spine auxiliary positioning which use 1, 2, 3, 4, 5 and 6 fiducials for tracking, respectively. Each phantom plan shall be repeatedly implemented 3 times. The E2E software is used to analyze the accuracy of irradiation and then the average value is acquired. The results of detecting the simulated human phantom: the accuracy of irradiation with 1 and 2 fiducials for tracking (combining with spine auxiliary positioning) was 1.11 mm and 1.05 mm; with 3, 4, 5 and 6 fiducials, the accuracy was 1.07 mm, 0.92 mm, 0.97 mm and 1.15 mm, respectively. The results of detecting dynamic lung phantom: with 1 and 2 fiducials used for tracking (combining with spine auxiliary positioning), the accuracy of irradiation was 1.03 mm and 0.70 mm; with 3, 4, 5 and 6 fiducials, the accuracy was 0.58 mm, 1.02 mm, 0.65 mm and 0.96 mm, respectively. For the relatively static tumor or moving tumor, if the rotation direction of tumor is consistent with spine, the accuracy of using 1 or 2 fiducials for tracking was the same as using 3 to 6 fiducials. When the number of fiducials is not enough, fiducial tracking along with spine auxiliary positioning can well solve this problem.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [21] Are plain radiographs of the spine necessary during evaluation after blunt trauma? Accuracy of screening torso computed tomography in thoracic/lumbar spine fracture diagnosis
    Berry, GE
    Adams, S
    Harris, MB
    Boles, CA
    McKernan, MG
    Collinson, F
    Hoth, JJ
    Meredith, JW
    Chang, MC
    Miller, PR
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (06): : 1410 - 1413
  • [22] Evaluation of prediction methods for real-time tumor tracking during treatment
    Sharp, G
    Jiang, SB
    Ruan, D
    Castañon, D
    Shirato, H
    MEDICAL PHYSICS, 2003, 30 (06) : 1346 - 1346
  • [23] Evaluation of Dynamic Tumour Tracking (DTT) uncertainty for a Fiducial-Based Stereotactic Ablative Radiotherapy (SABR) Treatment of the Liver Using EPID Images
    Rostamzadeh, M.
    Bergman, A.
    Luchka, K.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [24] Does obesity affect the accuracy and detection rate of congenital anomalies during ultrasound evaluation?
    Colon, Maria
    Qato, Roa
    Wilkins, Isabelle
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2009, 201 (06) : S129 - S130
  • [25] JCV detection in the urine increases accuracy of PML risk stratification during natalizumab treatment
    Ferrante, Pasquale
    Elia, Francesca
    Pecchenini, Valentina
    Gastaldi, Matteo
    Colombo, Elena
    Franciotta, Diego
    Carloni, Camilla
    Bergamaschi, Roberto
    Ferrante, Pasquale
    JOURNAL OF NEUROVIROLOGY, 2013, 19 (03) : 307 - 308
  • [26] Evaluation of a mobile C-arm capable of cone beam CT used for real time positioning: accuracy studies using optical tracking
    Sorensen, S
    Mitschke, M
    Agazaryan, N
    Medin, P
    Solberg, T
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S162 - S162
  • [27] Are plain radiographs of the spine necessary during evaluation after blunt trauma? Accuracy of screening torso computed tomography in thoracic/lumbar spine fracture diagnosis - Editorial comment
    Hauser, CJ
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (06): : 1413 - 1413
  • [28] An Innovative Tracking Device to Improve Left Breast Treatment Accuracy during the Deep Inspiration Breath Hold Technique
    Urribarri, J.
    Scholl, K.
    Berbeco, R.
    Lingos, T.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] Evaluation of the accuracy of cone-beam based patient positioning for treatment of spinal lesions and efficacy of adaptive strategies to maximize the cord sparing
    Harrison, A.
    Bednarz, G.
    Galvin, J. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S691 - S691
  • [30] Prostate intrafraction motion evaluation using kV fluoroscopy during treatment delivery: A feasibility and accuracy study
    Adamson, Justus
    Wu, Qiuwen
    MEDICAL PHYSICS, 2008, 35 (05) : 1793 - 1806