Investigation on heat transfer characteristics of outside heat exchanger in an air conditioning heat pump system for electric vehicles

被引:7
|
作者
Yu, Jun [1 ]
Su, Lin [1 ,2 ]
Li, Kang [1 ,2 ]
Liu, Mingkang [1 ]
Zhang, Hua [1 ,2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Univ Shanghai Sci & Technol, Key Lab Multiphase Flow & Heat Transfer Shanghai, Shanghai 200093, Peoples R China
关键词
Microchannel heat exchanger; Nusselt number; Heat transfer rate; PRESSURE-DROP; REFRIGERANT CHARGE; CONDENSATION; PREDICTION; R134A;
D O I
10.1016/j.ijheatmasstransfer.2021.121040
中图分类号
O414.1 [热力学];
学科分类号
摘要
The development of thermal management systems in electric vehicles challenges new understandings of outside heat exchangers. The increasing heat load of electric vehicles requires a corresponding improvement in their heat exchanger characteristics. The purpose of this work is to modify the classical Nusselt number correlation model through experiments to check and predict the heat transfer characteristics of such a heat exchanger. In this paper, a parallel flow microchannel outside heat exchanger was studied with experiments and numerical simulations. Heat transfer correlations on the air side were modified by experimental data obtained from a newly designed test bench. Experimental results show that the heat transfer rate increases with increasing inlet pressure and inlet airflow. Furthermore, a numerical model for predicting heat exchanger characteristics was also proposed with the modified Nusselt number correlations. The comparison between modeling and experimental heat transfer rate shows good agreement, in which the absolute errors of the corresponding heat transfer characteristics for the heat exchanger are within 25%. The typical heat transfer model with the j-factor was also applied to predict the heat transfer rate. Comparison between results of modeling and experiment shows that models with the modified Nusselt number correlations demonstrate advantages when predicting the outside heat exchanger characteristics in an air conditioning heat pump system. The Nusselt number correlation model has good applicability for various environmental conditions. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Investigation of heat transfer and flow characteristics in heat exchanger with microscale channels
    Xu, Shaokun
    Chen, Baoming
    Ji, Shui
    Zhao, Shiqi
    [J]. ICNMM2007: PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, 2007, : 631 - 637
  • [42] Effects of face velocity of outdoor heat exchanger on frosting characteristics of air source heat pump system
    Guo, Xianmin
    Wang, Dongli
    Chen, Yiguang
    Wang, Weihua
    [J]. Huagong Xuebao/CIESC Journal, 2012, 63 (SUPPL. 2): : 32 - 37
  • [43] Investigation on the performance and characteristics of a heat pump system for electric vehicles under extreme temperature conditions
    Li, Kang
    Luo, Shuxian
    Fan, Le
    Hu, Shasha
    Zhou, Xuejin
    Tu, Ran
    Zhang, Huiqi
    Jin, Xiaotang
    Zhao, Xiaoshan
    Su, Lin
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2021, 27
  • [44] Heat Transfer Performance Factors in a Vertical Ground Heat Exchanger for a Geothermal Heat Pump System
    Salhein, Khaled
    Kobus, C.J.
    Zohdy, Mohamed
    Annekaa, Ahmed M.
    Alhawsawi, Edrees Yahya
    Salheen, Sabriya Alghennai
    [J]. Energies, 2024, 17 (19)
  • [45] Experiment investigation about enhanced heat transfer of underground heat exchanger in ground source heat pump
    Gao, Q
    Yu, M
    Li, M
    Qiao, G
    Fang, Y
    [J]. PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 553 - 558
  • [46] APPLIED HORIZONTAL AND VERTICAL GEOTHERMAL HEAT EXCHANGER WITH HEAT PUMP SYSTEM TO PROVIDE AIR CONDITIONING FOR AN ACADEMIC FACILITY IN MEXICO
    Martinez Daniel, Alcantar
    Oskar Javier, Gonzalez Pedraza
    Covarrubias Crisanto, M.
    Jesus, Pacheco Ibarra J.
    Jorge Alberto, Rangel Arista
    [J]. 2016 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2016,
  • [47] Analysis of heat transfer on heat recovery exchanger of separate heat pipe applying to heat pump drying system
    [J]. Du, K., 2001, Chinese Society for Electrical Engineering (21):
  • [48] Reversible heat pump HVAC system with regenerative heat exchanger for electric vehicles: Analysis of its impact on driving range
    Bellocchi, Sara
    Guizzi, Giuseppe Leo
    Manno, Michele
    Salvatori, Marco
    Zaccagnini, Alessandro
    [J]. APPLIED THERMAL ENGINEERING, 2018, 129 : 290 - 305
  • [49] A Study of Optimal Refrigerant Charge Amount Determination for Air-Conditioning Heat Pump System in Electric Vehicles
    Li, Kang
    Yu, Jun
    Liu, Mingkang
    Xu, Dan
    Su, Lin
    Fang, Yidong
    [J]. ENERGIES, 2020, 13 (03)
  • [50] An intelligent eco-heating control strategy for heat-pump air conditioning system of electric vehicles
    Xie, Yi
    Ou, Jingzhi
    Li, Wei
    Li, Kuining
    Liu, Jiangyan
    Liu, Zhaoming
    Zhou, Degen
    Li, Jingyuan
    [J]. APPLIED THERMAL ENGINEERING, 2022, 216