Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale

被引:27
|
作者
Monte, Ines [1 ]
Grasso, Stefania [1 ]
Licciardi, Salvatore [1 ]
Badano, Luigi P. [2 ]
机构
[1] Policlin Univ, Echo Dept, I-95125 Catania, Italy
[2] Univ Hosp, Dept Cardiopulm Sci, Udine, Italy
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2010年 / 11卷 / 03期
关键词
Echocardiography; Contrast; Three-dimensional echocardiography; Patent foramen ovale; Transesophageal; Cryptogenetic stroke; Divers; INTERATRIAL SHUNTS; AIR-EMBOLISM; TECHNOLOGY; ASSOCIATION; COMMITTEE;
D O I
10.1093/ejechocard/jep195
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the incremental value of real-time three-dimensional echocardiography (RT-3DTE) over contrast transthoracic echocardiography (TTE), compared with contrast transesophageal echocardiography (TEE) in the identification of patent foramen ovale (PFO). Eighty-one consecutive patients with history of migraine headache (MH) or unexplained cerebrovascular events (CE) were examined using RT-3DTE, contrast TTE, and contrast TEE in sequence. Feasibility of RT-3DE in patients with MH and CE was 98 and 91%, respectively. Mean time for 3D colour data set acquisition was 9 +/- 5 min. PFO was diagnosed using contrast TEE in 36 patients (overall prevalence = 44%). Diagnostic accuracy of RT-3DE was significantly higher than that of contrast TTE: sensitivity 83 vs. 44%, P < 0.001; specificity 100 vs. 100%, P7 = NS; positive predictive value 100 vs. 100%, P = NS; negative predictive value 88 vs. 69%, P < 0.01; accuracy 93 vs. 75%, P < 0.003. Five of the six patients in whom RT-3DTE did not identify PFOs showed a defect diameter smaller than 2 mm. RT-3DTE is a feasible, accurate, and reproducible technique to detect PFO without the need of saline contrast injection. Its accuracy is superior to contrast 2D TTE and close to that of contrast TEE.
引用
收藏
页码:245 / 249
页数:5
相关论文
共 50 条
  • [41] Real-Time 3-Dimensional Transesophageal Echocardiography for the Diagnosis of a Thrombus Straddling the Patent Foramen Ovale
    Rinaldi, Jean-Paul
    Latcu, Decebal Gabriel
    Saoudi, Nadir
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (04) : E7 - E7
  • [42] Real Time Three-Dimensional transthoracic echocardiographic visualization of the valve of foramen ovale
    Panwar, Sadik R.
    Perrien, James L.
    Nanda, Navin C.
    Singh, Anurag
    Rajdev, Sanjay
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (10): : 1105 - 1107
  • [43] Three-dimensional Echocardiography for Percutaneous Occlusion of Patent Foramen Ovale
    Poffo, Robinson
    Montanhesi, Paola Keese
    Pope, Renato Bastos
    Toschi, Alisson Parrilha
    Vieira, Marcelo Campos
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2016, 106 (03) : 263 - 264
  • [44] Diagnosis of patent foramen ovale by transthoracic echocardiography using second harmonic imaging: comparison of three contrast agents
    Lefevre, J
    Lafitte, S
    Perron, JM
    Jais, C
    Coste, P
    Roudaut, R
    EUROPEAN HEART JOURNAL, 2002, 23 : 177 - 177
  • [45] A comparison of contrast transthoracic echocardiography and contrast transcranial Doppler in cryptogenic stroke patients with patent foramen ovale
    Chen, Jie
    Chen, Luyun
    Hu, Wangwang
    Ni, Xianda
    Zhang, Zengrui
    Feng, Xiaowen
    Fan, Zijian
    Chen, Cuiping
    Qiu, Fengzhen
    Shao, Bei
    BRAIN AND BEHAVIOR, 2019, 9 (05):
  • [46] Optimization of patent foramen ovale detection by contrast transthoracic echocardiography using second harmonic imaging
    Lefevre, J.
    Lafitte, S.
    Reant, P.
    Perron, J. -M.
    Roudaut, R.
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2008, 101 (04) : 213 - 219
  • [47] COMPARISON OF TRANSTHORACIC TWO-DIMENSIONAL ECHOCARDIOGRAPHY, THREE-DIMENSIONAL ECHOCARDIOGRAPHY, TRANSESOPHAGEAL ECHOCARDIOGRAPHY, COMPUTED TOMOGRAPHY ANGIOGRAPHY, AND GATED MAGNETIC RESONANCE IMAGING IN NORMAL CANINE HEARTS.
    Fries, R. C.
    Gordon, S. G.
    Miller, M. W.
    Saunders, A. B.
    Hariu, C. D.
    Bogess, M.
    Lennox, M.
    Fossum, T. W.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2012, 26 (03) : 710 - 710
  • [48] Real Time Three-Dimensional Transthoracic Echocardiography in Congenital Heart Disease
    Hage, Fadi G.
    Raslan, Saleem
    Dean, Phillip
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (02): : 220 - 231
  • [49] Comparison of Real-Time Three-Dimensional Transesophageal Echocardiography to Two-Dimensional Transesophageal Echocardiography for Quantification of Mitral Valve Prolapse in Patients With Severe Mitral Regurgitation
    Izumo, Masaki
    Shiota, Maiko
    Kar, Saibal
    Gurudevan, Swaminatha V.
    Tolstrup, Kirsten
    Siegel, Robert J.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (04): : 588 - 594
  • [50] Incremental Value of Three-Dimensional Transesophageal Echocardiography over the Two-Dimensional Technique in the Assessment of a Thrombus in Transit through a Patent Foramen Ovale
    Thind, Munveer
    Ahmed, Mustafa I.
    Gok, Gulay
    Joson, Marisa
    Elsayed, Mahmoud
    Tuck, Benjamin C.
    Townsley, Matthew M.
    Klas, Berthold
    McGiffin, David C.
    Nanda, Navin C.