Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale

被引:27
|
作者
Monte, Ines [1 ]
Grasso, Stefania [1 ]
Licciardi, Salvatore [1 ]
Badano, Luigi P. [2 ]
机构
[1] Policlin Univ, Echo Dept, I-95125 Catania, Italy
[2] Univ Hosp, Dept Cardiopulm Sci, Udine, Italy
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2010年 / 11卷 / 03期
关键词
Echocardiography; Contrast; Three-dimensional echocardiography; Patent foramen ovale; Transesophageal; Cryptogenetic stroke; Divers; INTERATRIAL SHUNTS; AIR-EMBOLISM; TECHNOLOGY; ASSOCIATION; COMMITTEE;
D O I
10.1093/ejechocard/jep195
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the incremental value of real-time three-dimensional echocardiography (RT-3DTE) over contrast transthoracic echocardiography (TTE), compared with contrast transesophageal echocardiography (TEE) in the identification of patent foramen ovale (PFO). Eighty-one consecutive patients with history of migraine headache (MH) or unexplained cerebrovascular events (CE) were examined using RT-3DTE, contrast TTE, and contrast TEE in sequence. Feasibility of RT-3DE in patients with MH and CE was 98 and 91%, respectively. Mean time for 3D colour data set acquisition was 9 +/- 5 min. PFO was diagnosed using contrast TEE in 36 patients (overall prevalence = 44%). Diagnostic accuracy of RT-3DE was significantly higher than that of contrast TTE: sensitivity 83 vs. 44%, P < 0.001; specificity 100 vs. 100%, P7 = NS; positive predictive value 100 vs. 100%, P = NS; negative predictive value 88 vs. 69%, P < 0.01; accuracy 93 vs. 75%, P < 0.003. Five of the six patients in whom RT-3DTE did not identify PFOs showed a defect diameter smaller than 2 mm. RT-3DTE is a feasible, accurate, and reproducible technique to detect PFO without the need of saline contrast injection. Its accuracy is superior to contrast 2D TTE and close to that of contrast TEE.
引用
收藏
页码:245 / 249
页数:5
相关论文
共 50 条
  • [31] Echocardiographic Guidance of Percutaneous Patent Foramen Ovale Closure: Head-to-Head Comparison of Transesophageal versus Rotational Intracardiac Echocardiography
    Vigna, Carlo
    Marchese, Nicola
    Zanchetta, Mario
    Chessa, Massimo
    Inchingolo, Vincenzo
    Pacilli, Michele Antonio
    Amico, Cesare
    Fanelli, Mario
    Fanelli, Raffaele
    Loperfido, Francesco
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (09): : 1103 - 1110
  • [32] Cor triatriatum sinistrum: a real-time three-dimensional transthoracic echocardiography evaluation
    Sirugo, L.
    Licciardi, S.
    Monte, I.
    MINERVA CARDIOANGIOLOGICA, 2011, 59 (01): : 116 - 118
  • [33] Visualization of atrial septal aneurysm and patent foramen ovale by three-dimensional transesophageal echocardiography
    Najib, Mohammad Q.
    Ganji, Jhansi L.
    Chaliki, Hari P.
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2016, 17 : E237 - E238
  • [34] Real-time three-dimensional transthoracic echocardiography in daily practice: initial experience
    Ashraf M Anwar
    Youssef FM Nosir
    Siti Khairani Zainal-Abidin
    Aref Ajam
    Hassan Chamsi-Pasha
    Cardiovascular Ultrasound, 10
  • [35] Real time three dimensional transthoracic echocardiography for planning mitral reconstructive surgery: A comparison with two dimensional transoesophageal echocardiography
    Sharma, R
    Mann, J
    Drummond, L
    Livesey, S
    Simpson, I
    HEART, 2006, 92 : A74 - A74
  • [36] Three-dimensional echocardiography in adult patients: Comparison between transthoracic and transesophageal reconstructions
    Godoy, IE
    Bednarz, J
    Sugeng, L
    Mor-Avi, V
    Spencer, KT
    Lang, RM
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (12) : 1045 - 1052
  • [37] Which Technique Is Better for Detection of Right-to-Left Shunt in Patients with Patent Foramen Ovale: Comparing Contrast Transthoracic Echocardiography with Contrast Transesophageal Echocardiography
    Yue Li
    Zhai Ya-nan
    Wei Li-qun
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (09): : 1050 - 1055
  • [38] Real-time three-dimensional transthoracic echocardiography in daily practice: initial experience
    Anwar, Ashraf M.
    Nosir, Youssef F. M.
    Zainal-Abidin, Siti Khairani
    Ajam, Aref
    Chamsi-Pasha, Hassan
    CARDIOVASCULAR ULTRASOUND, 2012, 10
  • [39] Role of real-time three-dimensional transoesophageal echocardiography for guiding transcatheter patent foramen ovale closure
    Martin-Reyes, Roberto
    Lopez-Fernandez, Teresa
    Moreno-Yanguela, Mar
    Moreno, Raul
    Angel Navas-Lobato, Miguel
    Refoyo, Elena
    Guzman, Gabriela
    Dominguez-Melcon, Francisco
    Luis Lopez-Sendon, Jose
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01): : 148 - 150
  • [40] Added Value of Real-time Three-dimensional Transoesophageal Echocardiography in Percutaneous Closure of the Patent Foramen Ovale
    De Maeyer, Catherine
    Bert, Suys
    De Wolf, Daniel
    Vrints, Christiaan J.
    Paelinck, Bernard P.
    CIRCULATION, 2009, 120 (18) : S392 - S392