Free-breathing simultaneous T1, T2, and T2* quantification in the myocardium

被引:0
|
作者
Hermann, Ingo [1 ,2 ]
Kellman, Peter [3 ]
Demirel, Omer B. [4 ,5 ]
Akcakaya, Mehmet [4 ,5 ]
Schad, Lothar R. [2 ]
Weingartner, Sebastian [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Magnet Resonance Syst Lab, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[3] NHLBI, NIH, DHHS, Bldg 10, Bethesda, MD 20892 USA
[4] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
cardiac quantitative imaging; free-breathing; T-1; mapping; T-2; T-2* mapping; MAGNETIC-RESONANCE SCMR; EXTRACELLULAR VOLUME; SATURATION-RECOVERY; INVERSION-RECOVERY; T2; QUANTIFICATION; IN-VIVO; T1; HEART; RECONSTRUCTION; ANGIOGRAPHY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement a free-breathing sequence for simultaneous quantification of T-1, T-2, and T-2* for comprehensive tissue characterization of the myocardium in a single scan using a multi-gradient-echo readout with saturation and T-2 preparation pulses. Methods In the proposed Saturation And T-2-prepared Relaxometry with Navigator-gating (SATURN) technique, a series of multi-gradient-echo (GRE) images with different magnetization preparations was acquired during free breathing. A total of 35 images were acquired in 26.5 +/- 14.9 seconds using multiple saturation times and T-2 preparation durations and with imaging at 5 echo times. Bloch simulations and phantom experiments were used to validate a 5-parameter fit model for accurate relaxometry. Free-breathing simultaneous T-1, T-2, and T-2* measurements were performed in 10 healthy volunteers and 2 patients using SATURN at 3T and quantitatively compared to conventional single-parameter methods such as SASHA for T-1, T-2-prepared bSSFP, and multi-GRE for T-2*. Results Simulations confirmed accurate fitting with the 5-parameter model. Phantom measurements showed good agreement with the reference methods in the relevant range for in vivo measurements. Compared to single-parameter methods comparable accuracy was achieved. SATURN produced in vivo parameter maps that were visually comparable to single-parameter methods. No significant difference between T-1, T-2, and T-2* times acquired with SATURN and single-parameter methods was shown in quantitative measurements (SATURN T-1=1573 +/- 86ms, T-2=33.2 +/- 3.6ms, T-2*=25.3 +/- 6.1ms; conventional methods: T-1=1544 +/- 107ms, T-2=33.2 +/- 3.6ms, T-2*=23.8 +/- 5.5ms; P>.2) Conclusion SATURN enables simultaneous quantification of T-1, T-2, and T-2* in the myocardium for comprehensive tissue characterization with co-registered maps, in a single scan with good agreement to single-parameter methods.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Oxygen enhanced lung MRI by simultaneous measurement of T1 and T2* during free breathing using ultrashort TE
    Triphan, Simon M. F.
    Breuer, Felix A.
    Gensler, Daniel
    Kauczor, Hans-Ulrich
    Jakob, Peter M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (06) : 1708 - 1714
  • [32] Inversion recovery TrueFISP:: Quantification of T1, T2, and spin density
    Schmitt, P
    Griswold, MA
    Jakob, PM
    Kotas, M
    Gulani, V
    Flentje, M
    Haase, A
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 661 - 667
  • [33] Assessment of MRF for simultaneous T1 and T2 quantification and water-fat separation in the liver at 0.55 T
    Liu, Yuchi
    Hamilton, Jesse
    Jiang, Yun
    Seiberlich, Nicole
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (03) : 513 - 523
  • [34] Simultaneous perfusion, diffusion, T2*, and T1 mapping with MR fingerprinting
    Fan, Hongli
    Bunker, Lisa
    Wang, Zihan
    Durfee, Alexandra Zezinka
    Lin, Doris
    Yedavalli, Vivek
    Ge, Yulin
    Zhou, Xiaohong Joe
    Hillis, Argye E.
    Lu, Hanzhang
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 558 - 569
  • [35] Free-breathing T2*mapping using respiratory motion corrected averaging
    Kellman, Peter
    Xue, Hui
    Spottiswoode, Bruce S.
    Sandino, Christopher M.
    Hansen, Michael S.
    Abdel-Gadir, Amna
    Treibel, Thomas A.
    Rosmini, Stefania
    Mancini, Christine
    Bandettini, W. Patricia
    McGill, Laura-Ann
    Gatehouse, Peter
    Moon, James C.
    Pennell, Dudley J.
    Arai, Andrew E.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [36] Free-breathing T2* mapping using respiratory motion corrected averaging
    Peter Kellman
    Hui Xue
    Bruce S Spottiswoode
    Christopher M Sandino
    Michael S Hansen
    Amna Abdel-Gadir
    Thomas A Treibel
    Stefania Rosmini
    Christine Mancini
    W Patricia Bandettini
    Laura-Ann McGill
    Peter Gatehouse
    James C Moon
    Dudley J Pennell
    Andrew E Arai
    Journal of Cardiovascular Magnetic Resonance, 17
  • [37] Simultaneous perfusion, diffusion, T2*, and T1 mapping with MR fingerprinting
    Fan, Hongli
    Bunker, Lisa
    Wang, Zihan
    Durfee, Alexandra Zezinka
    Lin, Doris
    Yedavalli, Vivek
    Ge, Yulin
    Zhou, Xiaohong Joe
    Hillis, Argye E.
    Lu, Hanzhang
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 558 - 569
  • [38] Simultaneous determination of metabolite concentrations, T1 and T2 relaxation times
    An, Li
    Li, Shizhe
    Shen, Jun
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2072 - 2081
  • [39] Joint Reconstruction of Multiple Images and Motion in MRI: Application to Free-Breathing Myocardial T2 Quantification
    Odille, Freddy
    Menini, Anne
    Escanye, Jean-Marie
    Vuissoz, Pierre-Andre
    Marie, Pierre-Yves
    Beaumont, Marine
    Felblinger, Jacques
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (01) : 197 - 207
  • [40] T1ρ, T2 and T2*mapping of lumbar intervertebral disc degeneration: a comparison study
    Yang, Li
    Sun, Cong
    Gong, Tao
    Li, Quanlin
    Chen, Xin
    Zhang, Xinjuan
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)