Free-breathing simultaneous T1, T2, and T2* quantification in the myocardium

被引:0
|
作者
Hermann, Ingo [1 ,2 ]
Kellman, Peter [3 ]
Demirel, Omer B. [4 ,5 ]
Akcakaya, Mehmet [4 ,5 ]
Schad, Lothar R. [2 ]
Weingartner, Sebastian [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Magnet Resonance Syst Lab, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[3] NHLBI, NIH, DHHS, Bldg 10, Bethesda, MD 20892 USA
[4] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
cardiac quantitative imaging; free-breathing; T-1; mapping; T-2; T-2* mapping; MAGNETIC-RESONANCE SCMR; EXTRACELLULAR VOLUME; SATURATION-RECOVERY; INVERSION-RECOVERY; T2; QUANTIFICATION; IN-VIVO; T1; HEART; RECONSTRUCTION; ANGIOGRAPHY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement a free-breathing sequence for simultaneous quantification of T-1, T-2, and T-2* for comprehensive tissue characterization of the myocardium in a single scan using a multi-gradient-echo readout with saturation and T-2 preparation pulses. Methods In the proposed Saturation And T-2-prepared Relaxometry with Navigator-gating (SATURN) technique, a series of multi-gradient-echo (GRE) images with different magnetization preparations was acquired during free breathing. A total of 35 images were acquired in 26.5 +/- 14.9 seconds using multiple saturation times and T-2 preparation durations and with imaging at 5 echo times. Bloch simulations and phantom experiments were used to validate a 5-parameter fit model for accurate relaxometry. Free-breathing simultaneous T-1, T-2, and T-2* measurements were performed in 10 healthy volunteers and 2 patients using SATURN at 3T and quantitatively compared to conventional single-parameter methods such as SASHA for T-1, T-2-prepared bSSFP, and multi-GRE for T-2*. Results Simulations confirmed accurate fitting with the 5-parameter model. Phantom measurements showed good agreement with the reference methods in the relevant range for in vivo measurements. Compared to single-parameter methods comparable accuracy was achieved. SATURN produced in vivo parameter maps that were visually comparable to single-parameter methods. No significant difference between T-1, T-2, and T-2* times acquired with SATURN and single-parameter methods was shown in quantitative measurements (SATURN T-1=1573 +/- 86ms, T-2=33.2 +/- 3.6ms, T-2*=25.3 +/- 6.1ms; conventional methods: T-1=1544 +/- 107ms, T-2=33.2 +/- 3.6ms, T-2*=23.8 +/- 5.5ms; P>.2) Conclusion SATURN enables simultaneous quantification of T-1, T-2, and T-2* in the myocardium for comprehensive tissue characterization with co-registered maps, in a single scan with good agreement to single-parameter methods.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Assessment of MRF for simultaneous T1 and T2 quantification and water–fat separation in the liver at 0.55 T
    Yuchi Liu
    Jesse Hamilton
    Yun Jiang
    Nicole Seiberlich
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2023, 36 : 513 - 523
  • [22] THE T1 AND T2 REPRESENTABILITY CONDITIONS
    Braams, Bastiaan J.
    Percus, Jerome K.
    Zhao, Zhengji
    [J]. REDUCED-DENSITY-MATRIX MECHANICS - WITH APPLICATION TO MANY-ELECTRON ATOMS AND MOLECULES, 2007, 134 : 93 - 101
  • [23] Time related changes of T1, T2, and T2* of human blood in vitro
    Petrovic, Andreas
    Krauskopf, Astrid
    Hassler, Eva
    Stollberger, Rudolf
    Scheurer, Eva
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2016, 262 : 11 - 17
  • [24] MRI Signal in Biological Tissues - Proton, Spin, T1, T2, T2☆
    Gorny, K.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3816 - 3816
  • [25] Free-breathing 3D whole-heart joint T1/T2 mapping and water/fat imaging at 0.55 T
    Si, Dongyue
    Crabb, Michael G.
    Kunze, Karl P.
    Littlewood, Simon J.
    Prieto, Claudia
    Botnar, Rene M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1511 - 1524
  • [26] Three-dimensional simultaneous brain mapping of T1, T2, T2*and magnetic susceptibility with MR Multitasking
    Cao, Tianle
    Ma, Sen
    Wang, Nan
    Gharabaghi, Sara
    Xie, Yibin
    Fan, Zhaoyang
    Hogg, Elliot
    Wu, Chaowei
    Han, Fei
    Tagliati, Michele
    Haacke, E. Mark
    Christodoulou, Anthony G.
    Li, Debiao
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (03) : 1375 - 1389
  • [27] A novel free-breathing abdominal RAVE T2/T1 hybrid MRI sequence in patients with cystic fibrosis: Preliminary results
    Glutig, Katja
    Krueger, Paul-Christian
    Oberreuther, Theresa
    Teichgraeber, Ulf
    Lorenz, Michael
    Mentzel, Hans-Joachim
    Kraemer, Martin
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2022, 154
  • [28] Free-breathing multi-slice myocardial T2 mapping using slice-selective T2 magnetization preparation
    Tamer Basha
    Sébastien Roujol
    Sophie Berg
    Warren J Manning
    Reza Nezafat
    [J]. Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [29] Oxygen enhanced lung MRI by simultaneous measurement of T1 and T2* during free breathing using ultrashort TE
    Triphan, Simon M. F.
    Breuer, Felix A.
    Gensler, Daniel
    Kauczor, Hans-Ulrich
    Jakob, Peter M.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (06) : 1708 - 1714
  • [30] Inversion recovery TrueFISP:: Quantification of T1, T2, and spin density
    Schmitt, P
    Griswold, MA
    Jakob, PM
    Kotas, M
    Gulani, V
    Flentje, M
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 661 - 667