Free-breathing simultaneous T1, T2, and T2* quantification in the myocardium

被引:0
|
作者
Hermann, Ingo [1 ,2 ]
Kellman, Peter [3 ]
Demirel, Omer B. [4 ,5 ]
Akcakaya, Mehmet [4 ,5 ]
Schad, Lothar R. [2 ]
Weingartner, Sebastian [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Magnet Resonance Syst Lab, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[3] NHLBI, NIH, DHHS, Bldg 10, Bethesda, MD 20892 USA
[4] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
cardiac quantitative imaging; free-breathing; T-1; mapping; T-2; T-2* mapping; MAGNETIC-RESONANCE SCMR; EXTRACELLULAR VOLUME; SATURATION-RECOVERY; INVERSION-RECOVERY; T2; QUANTIFICATION; IN-VIVO; T1; HEART; RECONSTRUCTION; ANGIOGRAPHY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement a free-breathing sequence for simultaneous quantification of T-1, T-2, and T-2* for comprehensive tissue characterization of the myocardium in a single scan using a multi-gradient-echo readout with saturation and T-2 preparation pulses. Methods In the proposed Saturation And T-2-prepared Relaxometry with Navigator-gating (SATURN) technique, a series of multi-gradient-echo (GRE) images with different magnetization preparations was acquired during free breathing. A total of 35 images were acquired in 26.5 +/- 14.9 seconds using multiple saturation times and T-2 preparation durations and with imaging at 5 echo times. Bloch simulations and phantom experiments were used to validate a 5-parameter fit model for accurate relaxometry. Free-breathing simultaneous T-1, T-2, and T-2* measurements were performed in 10 healthy volunteers and 2 patients using SATURN at 3T and quantitatively compared to conventional single-parameter methods such as SASHA for T-1, T-2-prepared bSSFP, and multi-GRE for T-2*. Results Simulations confirmed accurate fitting with the 5-parameter model. Phantom measurements showed good agreement with the reference methods in the relevant range for in vivo measurements. Compared to single-parameter methods comparable accuracy was achieved. SATURN produced in vivo parameter maps that were visually comparable to single-parameter methods. No significant difference between T-1, T-2, and T-2* times acquired with SATURN and single-parameter methods was shown in quantitative measurements (SATURN T-1=1573 +/- 86ms, T-2=33.2 +/- 3.6ms, T-2*=25.3 +/- 6.1ms; conventional methods: T-1=1544 +/- 107ms, T-2=33.2 +/- 3.6ms, T-2*=23.8 +/- 5.5ms; P>.2) Conclusion SATURN enables simultaneous quantification of T-1, T-2, and T-2* in the myocardium for comprehensive tissue characterization with co-registered maps, in a single scan with good agreement to single-parameter methods.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A three-dimensional free-breathing sequence for simultaneous myocardial T1 and T2 mapping
    Guo, Rui
    Chen, Zhensen
    Herzka, Daniel A.
    Luo, Jianwen
    Ding, Haiyan
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1031 - 1043
  • [2] Free-breathing simultaneous native myocardial T1, T2 and T1ρ mapping with Cartesian acquisition and dictionary matching
    Zhenfeng Lyu
    Sha Hua
    Jian Xu
    Yiwen Shen
    Rui Guo
    Peng Hu
    Haikun Qi
    [J]. Journal of Cardiovascular Magnetic Resonance, 25
  • [3] Free-breathing simultaneous native myocardial T1, T2 and T1ρ mapping with Cartesian acquisition and dictionary matching
    Lyu, Zhenfeng
    Hua, Sha
    Xu, Jian
    Shen, Yiwen
    Guo, Rui
    Hu, Peng
    Qi, Haikun
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [4] Free-breathing simultaneous T-1, T-2, and T-2(*) quantification in the myocardium
    Hermann, Ingo
    Kellman, Peter
    Demirel, Omer B.
    Akcakaya, Mehmet
    Schad, Lothar R.
    Weingartner, Sebastian
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (03) : 1226 - 1240
  • [5] Simultaneous acquisition for T2 - T2 Exchange and T1 - T2 correlation NMR experiments
    Montrazi, Elton T.
    Lucas-Oliveira, Everton
    Araujo-Ferreira, Arthur G.
    Barsi-Andreeta, Mariane
    Bonagamba, Tito J.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2018, 289 : 63 - 71
  • [6] Simultaneous whole-liver water T1 and T2 mapping with isotropic resolution during free-breathing
    Stelter, Jonathan
    Weiss, Kilian
    Steinhelfer, Lisa
    Spieker, Veronika
    Moquillaza, Elizabeth Huaroc
    Zhang, Weitong
    Makowski, Marcus R.
    Schnabel, Julia A.
    Kainz, Bernhard
    Braren, Rickmer F.
    Karampinos, Dimitrios C.
    [J]. NMR IN BIOMEDICINE, 2024,
  • [7] Myocardial T1 and T2 mappings with automatic motion correction at 3 Tesla MR: comparison of T1 and T2 measurements by breathhold, free-breathing and cardiac cycle
    Yon Mi Sung
    Hwanseok Yong
    [J]. Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [8] Free-breathing myocardial T2 measurements at 1.5T
    Maelene Lohezic
    Anne Menini
    Jean-Marie Escanyé
    Pierre-Yves Marie
    Damien Mandry
    Pierre-André Vuissoz
    Jacques Felblinger
    [J]. Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [9] Free-breathing, non-ECG, simultaneous myocardial T1, T2, T2, and fat-fraction mapping with motion-resolved cardiovascular MR multitasking
    Cao, Tianle
    Wang, Nan
    Kwan, Alan C.
    Lee, Hsu-Lei
    Mao, Xianglun
    Xie, Yibin
    Nguyen, Kim-Lien
    Colbert, Caroline M.
    Han, Fei
    Han, Pei
    Han, Hui
    Christodoulou, Anthony G.
    Li, Debiao
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (04) : 1748 - 1763
  • [10] Simultaneous T1, T2, and T2*Mapping of Carotid Plaque: The SIMPLE* Technique
    Wang, Yajie
    Liu, Xiaoming
    Wang, Jing
    Wang, Yishi
    Qi, Haikun
    Kong, Xiangchuang
    Liu, Dingxi
    Liu, Jia
    Zheng, Hanpei
    Xiong, Fu
    Zhang, Lan
    Fu, Xiaona
    Zhang, Xinli
    Guo, Rui
    Qiao, Huiyu
    Chen, Zhensen
    Si, Dongyue
    Chen, Huijun
    [J]. RADIOLOGY, 2023, 307 (03)