We demonstrate temperature measurement of a sample attached to the end of a cantilever using cantilever magnetometry of solid air "contamination" of the sample surface. In experiments like our magnetic resonance force microscopy (MRFM), the sample is mounted at the end of a thin cantilever with small thermal conductance. Thus, the sample can be at a significantly different temperature than the bulk of the instrument. Using cantilever magnetometry of the oxygen paramagnetism in solid air provides the temperature of the sample, without any modifications to our MRFM apparatus. (C) 2003 American Institute of Physics.
引用
收藏
页码:4297 / 4299
页数:3
相关论文
共 50 条
  • [41] Temperature independent resistive oxygen sensors using solid electrolyte zirconia as a new temperature compensating material
    Izu, N
    Shin, W
    Matsubara, I
    Murayama, N
    Oh-hori, N
    Itou, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) : 216 - 222
  • [42] Measurement of atomic oxygen in the middle atmosphere using solid electrolyte sensors and catalytic probes
    Eberhart, M.
    Loehle, S.
    Steinbeck, A.
    Binder, T.
    Fasoulas, S.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2015, 8 (09) : 3701 - 3714
  • [43] MEASUREMENT OF AFM CANTILEVER SPRING CONSTANT BY USING THE SURFACE PROFILE
    Kweon, Hyunkyu
    Nam, Kiho
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2010, 24 (18): : 3597 - 3606
  • [44] Measurement of cell forces using a microfabricated polymer cantilever sensor
    Ferrell, Nicholas
    Woodard, James
    Hansford, Derek J.
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 170 (1-2) : 84 - 89
  • [45] Measurement of transient surface temperature of conductive solid using thermocouples with different junctions
    Sun, Z. Q. (zqsun@csu.edu.cn), 1600, International Frequency Sensor Association, 46 Thorny Vineway, Toronto, ON M2J 4J2, Canada (148):
  • [46] Force Measurement and Intracellular Operation Using Customized AFM Cantilever
    Machida, Shinichi
    Nakayama, Takahiro W.
    Harada, Ichiro
    Afrin, Rehana
    Nakayama, Tomonobu
    Ikai, Atsushi
    BIOPHYSICAL JOURNAL, 2010, 98 (03) : 191A - 191A
  • [47] Bending Deformation Measurement of Bone Cantilever Using Image Correlation
    Hou, Zhende
    Yi, Weitian
    Yang, Lei
    Yue, Cheng
    ADVANCED MATERIALS AND PROCESSES, PTS 1-3, 2011, 311-313 : 1685 - 1688
  • [48] PULSE WAVE MEASUREMENT IN HUMAN USING PIEZORESISTIVE CANTILEVER ON LIQUID
    Kaneko, T.
    Minh-Dung, N.
    Quang-Khang, P.
    Takei, Y.
    Takahata, T.
    Matsumoto, K.
    Shimoyama, I.
    2015 28TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2015), 2015, : 670 - 673
  • [49] Quantitative Measurement of Cantilever Spring Constant Using Heterodyne Interferometer
    Su, Chanmin
    Fischi, Roland
    Shi, Jian
    Belikov, Sergey
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2009, 9 (02) : 736 - 740
  • [50] Contact sensors: The business end of temperature measurement
    Johnson, D
    CONTROL ENGINEERING, 1998, : 77 - +