Temperature measurement at the end of a cantilever using oxygen paramagnetism in solid air

被引:3
|
作者
Thurber, KR [1 ]
Harrell, LE
Smith, DD
机构
[1] USA, Res Lab, AMSRL SE EM, Adelphi, MD 20783 USA
[2] US Mil Acad, Dept Phys, W Point, NY 10996 USA
关键词
D O I
10.1063/1.1555837
中图分类号
O59 [应用物理学];
学科分类号
摘要
We demonstrate temperature measurement of a sample attached to the end of a cantilever using cantilever magnetometry of solid air "contamination" of the sample surface. In experiments like our magnetic resonance force microscopy (MRFM), the sample is mounted at the end of a thin cantilever with small thermal conductance. Thus, the sample can be at a significantly different temperature than the bulk of the instrument. Using cantilever magnetometry of the oxygen paramagnetism in solid air provides the temperature of the sample, without any modifications to our MRFM apparatus. (C) 2003 American Institute of Physics.
引用
收藏
页码:4297 / 4299
页数:3
相关论文
共 50 条
  • [21] MEASUREMENT OF GASEOUS OXYGEN TENSION UTILIZING PARAMAGNETISM - AN EVALUATION OF SERVOMEX OA.150 ANALYZER
    ELLIS, FR
    NUNN, JF
    BRITISH JOURNAL OF ANAESTHESIA, 1968, 40 (08) : 569 - &
  • [22] Measurement of oxygen content in air using the "Blue Bottle": An undergraduate lab exercise
    Terrel, Clifford E.
    Poindexter, Eric F.
    Schultz, Linda D.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [24] TECHNIQUES FOR MEASUREMENT OF OXYGEN AND AIR-TO-FUEL RATIO USING ZIRCONIA SENSORS
    BENAMMAR, M
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1994, 5 (07) : 757 - 767
  • [25] HIGH TEMPERATURE INTERFACIAL ADHESION STRENGTH MEASUREMENT IN ELECTRONIC PACKAGING USING THE DOUBLE CANTILEVER BEAM METHOD
    Sankarasubramanian, Santosh
    Cruz, Jaime
    Yazzie, Kyle
    Sundar, Vaasavi
    Subramanian, Vijay
    Cetegen, Edvin
    McCoy, David
    Malatkar, Pramod
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 10, 2017,
  • [26] Measurement of air temperature fields in radiative environments using optical fibers
    Moulouel, Rafik
    Houvin, Maxime
    Abadie, Marc
    Salagnac, Patrick
    Borel, Pascal
    Boldo, Didier
    MEASUREMENT, 2024, 230
  • [27] Research on air temperature measurement using low frequency sound waves
    Guo M.
    Yan Y.
    Lu G.
    Hu Y.
    Yan, Yong (yongyan@ncepu.edu.cn), 2018, Science Press (39): : 75 - 83
  • [28] Direct measurement of cantilever spring constants and correction for cantilever irregularities using an instrumented indenter
    Ying, Z. Charles
    Reitsma, Mark G.
    Gates, Richard S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (06):
  • [29] Measurement of mechanical properties using slender cantilever beams
    Vandeperre, L. J.
    Wang, X.
    Atkinson, A.
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2016, 36 (08) : 2003 - 2007
  • [30] Pressure measurement using hysteresis effects in cantilever microstructures
    Brown, K.B.
    Ma, Y.
    Garcia, A.
    Allegretto, W.
    Lawson, R.P.W.
    Vermeulen, F.E.
    Robinson, A.M.
    Canadian Journal of Electrical and Computer Engineering, 2000, 25 (01) : 43 - 47