Oxide Formation and Instrumental Mass Bias in MC-ICP-MS: An Isotopic Case Study of Neodymium

被引:12
|
作者
Freres, Evelyn [1 ]
Weis, Dominique [1 ]
Newman, Karla [2 ]
Amini, Marghaleray [1 ]
Gordon, Kathy [1 ]
机构
[1] Univ British Columbia, Pacific Ctr Isotop & Geochem Res, Dept Earth Ocean & Atmospher Sci, Vancouver, BC V6T 1Z4, Canada
[2] Trent Univ, Water Qual Ctr, 1600 West Bank Dr, Peterborough, ON K9J 8E5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
MC‐ ICP‐ MS; neodymium; isotope measurement; instrumental mass bias; oxide formation; INDUCTIVELY-COUPLED PLASMA; FRACTIONATION CORRECTION; OPERATING-CONDITIONS; SPECTROMETRY; ARGON; RATIOS; NITROGEN; TEMPERATURES; INTERFACE; SIGNALS;
D O I
10.1111/ggr.12381
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
High rates of oxide formation affect the magnitude and behaviour of instrumental mass bias for Nd isotopic measurements performed with multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) instruments, causing the traditional correction methods (e.g., internal and external normalisation) to fail. Here, we investigate the instrumental conditions that govern oxide formation and provide an extensive data set describing how different oxide formation rates affect the measurement error of Nd isotopic ratios. Results are reported for several instrumental set-ups including wet and dry plasma, different introduction methods, the addition of N-2, and various sampler and skimmer cone geometries. The differences in the behaviour of Nd isotopic ratios observed for dry and wet plasma require several reaction mechanisms to explain why oxide formation is associated with a non-linear mass bias for some rare earth elements. We developed a simple mathematical model to describe the behaviour of Nd isotopic ratios for a range of oxide formation rates and different instrumental settings and present a qualitative model that predicts the isotopic offsets of Nd ratios based on the cumulative contributions of the major sources of mass bias. A series of analytical recommendations for the determination of accurate and precise Nd ratios by MC-ICP-MS is presented.
引用
收藏
页码:501 / 523
页数:23
相关论文
共 50 条
  • [21] Precise determination of the isotopic composition of Sn using MC-ICP-MS
    Clayton, R
    Andersson, P
    Gale, NH
    Gillis, C
    Whitehouse, MJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) : 1248 - 1256
  • [22] Argide interference reduction for Fe isotopic analysis by MC-ICP-MS
    Aimoz, L.
    Barling, J.
    Deboudt, K.
    Flament, P.
    Weis, D.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A10 - A10
  • [23] Precise Determination of Stable Strontium Isotopic Compositions by MC-ICP-MS
    Xu, Juan
    Yang, Shouye
    Yang, Yueheng
    Liu, Yongsheng
    Xie, Xiaolei
    ATOMIC SPECTROSCOPY, 2020, 41 (02) : 64 - 73
  • [24] ACCURATE AND PRECISE DETERMINATION OF ISOTOPIC RATIOS BY MC-ICP-MS: A REVIEW
    Yang, Lu
    MASS SPECTROMETRY REVIEWS, 2009, 28 (06) : 990 - 1011
  • [25] Strontium-Neodymium isotopic compositions of eighteen geological Chinese reference materials measured on TIMS and MC-ICP-MS
    Wang, Wenke
    Wu, Jiaojiao
    Liu, Fang
    Li, Xin
    An, Yajun
    Zhang, Zhaofeng
    SOLID EARTH SCIENCES, 2025, 10 (01)
  • [26] High-precision and accurate determinations of neodymium isotopic compositions at nanogram levels in natural materials by MC-ICP-MS
    Huang, Kuo-Fang
    Blusztajn, Jerzy
    Oppo, Delia W.
    Curry, William B.
    Peucker-Ehrenbrink, Bernhard
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (09) : 1560 - 1567
  • [27] High-precision and accurate determinations of neodymium isotopic compositions at nanogram levels in natural materials by MC-ICP-MS
    Huang, Kuo-Fang
    Blusztajn, Jerzy
    Oppo, Delia W.
    Curry, William B.
    Peucker-Ehrenbrink, Bernhard
    Journal of Analytical Atomic Spectrometry, 2012, 27 (09): : 1560 - 1567
  • [28] Determination of mass-dependent molybdenum isotopic variations by MC-ICP-MS: An evaluation of matrix effects
    Pietruszka, AJ
    Walker, RJ
    Candela, PA
    CHEMICAL GEOLOGY, 2006, 225 (1-2) : 121 - 136
  • [29] A new concept for correction of instrumental isotopic fractionation in MC-ICP-MS using a pair of monoisotopic elements: a critical evaluation
    Tupys, Andrii
    Tetfejer, Klaudia
    Halicz, Ludwik
    Bulska, Ewa
    Karasinski, Jakub
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (12) : 3142 - 3150
  • [30] A Comparative Analysis of Mass Bias Correction Methods for Sr Isotope Ratio Determination by MC-ICP-MS
    Kasyanova, A., V
    Streletskaya, M., V
    Okuneva, T. G.
    Kiseleva, D., V
    VII INTERNATIONAL YOUNG RESEARCHERS' CONFERENCE - PHYSICS, TECHNOLOGY, INNOVATIONS (PTI-2020), 2020, 2313