Acetylcholinesterase biosensor based on prussian blue-modified electrode for detecting organophosphorous pesticides

被引:171
|
作者
Sun, Xia [1 ]
Wang, Xiangyou [1 ]
机构
[1] Shandong Univ Technol, Sch Agr & Food Engn, Zibo 255049, Shandong, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2010年 / 25卷 / 12期
基金
中国国家自然科学基金;
关键词
Biosensor; Prussian blue; Acetylcholinesterase; Pesticide residue; Modified electrode; NANOPARTICLES; CARBAMATE;
D O I
10.1016/j.bios.2010.04.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study, a novel acetylcholinesterase (AChE) biosensor was developed based on dual-layer membranes (chitosan membrane and prussian blue membrane) modifying glassy carbon electrode (GCE). A chitosan membrane was used for immobilizing AChE through glutaraldehyde cross-linking attachment to recognize pesticides selectively. A Prussian blue (PB) membrane was electrodeposited on the surface of GCE to enhance electron transfer. Before the detection, the chitosan enzyme membrane was quickly fixed on the surface of PB/GCE with O-ring to prepare an amperometric AChE-PB/GCE sensor for organophosphorus (OP) pesticides. The electrochemical behaviour of AChE-PB/GCE was studied, and the results showed that the chitosan membrane as carrier can absorb a large amount of enzyme, and PB has a significant synergistic effect towards enzymatic catalysis. As a result of these two important enhancement factors, the proposed biosensor exhibited extreme sensitivity to OP pesticides compared to the other kinds of AChE biosensor. The influences of phosphate buffer pH, substrate concentration, incubation time of pesticide on the response of the fabricated biosensor were investigated. Under optimum conditions, the inhibition rates of these pesticides were proportional to their concentrations in the range of 0.01-10 mu g l(-1), 0.05-10 mu g l(-1), 0.03-5 mu g l(-1), and 0.05-10 mu g l(-1), respectively. The detection limits were found to be 2.5 ng l(-1) for dichlorvos, 15 ng l(-1) for omethoate. 5 ng l(-1) for trichlorfon and 10 ng l(-1) for phoxim. Moreover, the biosensor exhibited good reproducibility and stability, and it was suitable for trace detection of OP pesticide residue. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2611 / 2614
页数:4
相关论文
共 50 条
  • [31] Prussian blue-modified nanoporous gold film electrode for amperometric determination of hydrogen peroxide
    Ghaderi, Seyran
    Mehrgardi, Masoud Ayatollahi
    BIOELECTROCHEMISTRY, 2014, 98 : 64 - 69
  • [32] A novel antimicrobial electrochemical glucose biosensor based on silver–Prussian blue-modified TiO2 nanotube arrays
    Farajpour, Nasim
    Deivanayagam, Ram
    Phakatkar, Abhijit
    Narayanan, Surya
    Shahbazian-Yassar, Reza
    Shokuhfar, Tolou
    Medical Devices and Sensors, 2020, 3 (02):
  • [33] An amperometric cholesterol biosensor based on cholesterol oxidase immobilized in polypyrrole on a Prussian blue modified electrode
    Li, JP
    Peng, TZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (06) : 669 - 673
  • [34] PHOTOELECTROCHEMICAL PROPERTIES OF PRUSSIAN BLUE-MODIFIED GLASSY-CARBON
    UPADHYAY, DN
    GOMATHI, H
    RAO, GP
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 301 (1-2): : 199 - 205
  • [35] A disposable biosensor with Prussian blue deposited electrode
    Yi, In-Je
    Kim, Ju-Ho
    Choi, Y. J.
    Kang, C. J.
    Kim, Yong-Sang
    MICROELECTRONIC ENGINEERING, 2006, 83 (4-9) : 1594 - 1597
  • [36] Electrochemical biosensor based on reduced graphene oxide modified electrode with Prussian blue and poly(toluidine blue O) coating
    Bai, Xiaoyun
    Chen, Guihua
    Shiu, Kwok-Keung
    ELECTROCHIMICA ACTA, 2013, 89 : 454 - 460
  • [37] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [38] Amperometric glucose biosensor with high sensitivity based on self-assembled Prussian Blue modified electrode
    Liu, Yu
    Chu, Zhenyu
    Zhang, Yannan
    Jin, Wanqin
    ELECTROCHIMICA ACTA, 2009, 54 (28) : 7490 - 7494
  • [39] Self-gelatinizable copolymer immobilized glucose biosensor based on Prussian Blue modified graphite electrode
    Deng, Q
    Li, B
    Dong, SJ
    ANALYST, 1998, 123 (10) : 1995 - 1999
  • [40] Amperometric glucose biosensors based on layer-by-layer assembly of chitosan and glucose oxidase on the Prussian blue-modified gold electrode
    Bing Yin
    Ruo Yuan
    Yaqing Chai
    Shihong Chen
    Shurui Cao
    Yang Xu
    Ping Fu
    Biotechnology Letters, 2008, 30 : 317 - 322