Prussian blue-modified nanoporous gold film electrode for amperometric determination of hydrogen peroxide

被引:44
|
作者
Ghaderi, Seyran [1 ]
Mehrgardi, Masoud Ayatollahi [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
关键词
Nanoporous gold film; Prussian blue; Hydrogen peroxide; Amperometric sensor; Electrocatalysis; SPECTROPHOTOMETRIC DETERMINATION; ELECTROCATALYTIC REDUCTION; ELECTROCHEMICAL SENSOR; SURFACE-AREA; NANOPARTICLES; BIOSENSOR; FABRICATION; GLUCOSE; H2O2; IMMOBILIZATION;
D O I
10.1016/j.bioelechem.2014.03.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this manuscript, the electrocatalytic reduction of hydrogen peroxides on Prussian blue (PB) modified nanoporous gold film (NPGF) electrode is described. The PB/NPGF is prepared by simple anodizing of a smooth gold film followed by PB film electrodeposition method. The morphology of the PB/NPGF electrode is characterized using scanning electron microscopy (SEM). The effect of solution pH and the scan rates on the voltammetric responses of hydrogen peroxide have also been examined. The amperometric determination of H2O2 shows two linear dynamic responses over the concentration range of 1 mu M-10 mu M and 10 mu M-100 mu M with a detection limit of 3.6 x 10(-7) M. Furthermore, this electrode demonstrated good stability, repeatability and selectivity remarkably. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 69
页数:6
相关论文
共 50 条
  • [1] Amperometric detection of hydrogen peroxide at a Prussian Blue-modified FTO electrode
    Tseng, KS
    Chen, LC
    Ho, KC
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) : 738 - 745
  • [2] Kinetic characterization of Prussian Blue-modified graphite electrodes for amperometric detection of hydrogen peroxide
    Cretu, Raluca C.
    Gligor, Delia M.
    Muresan, Laura
    Popescu, Ionel Catalin
    Muresan, Liana M.
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2006, 36 (12) : 1327 - 1332
  • [3] Kinetic characterization of Prussian Blue-modified graphite electrodes for amperometric detection of hydrogen peroxide
    Raluca C. Cretu
    Delia M. Gligor
    Laura Muresan
    Ionel Catalin Popescu
    Liana M. Muresan
    [J]. Journal of Applied Electrochemistry, 2006, 36 : 1327 - 1332
  • [4] Determination of hydrogen peroxide using a Prussian Blue modified macroporous gold electrode
    Jiao Yang
    Meng Lin
    MiSuk Cho
    Youngkwan Lee
    [J]. Microchimica Acta, 2015, 182 : 1089 - 1094
  • [5] Determination of hydrogen peroxide using a Prussian Blue modified macroporous gold electrode
    Yang, Jiao
    Lin, Meng
    Cho, MiSuk
    Lee, Youngkwan
    [J]. MICROCHIMICA ACTA, 2015, 182 (5-6) : 1089 - 1094
  • [6] Amperometric thiol sensor based on Prussian blue-modified glassy carbon electrode
    Kafi, A. K. M.
    Yin, Fan
    Shin, Hoon-Kyu
    Kwon, Young-Soo
    [J]. CURRENT APPLIED PHYSICS, 2007, 7 (05) : 496 - 499
  • [7] Nonenzymatic hydrogen peroxide sensor based on a Prussian Blue-modified carbon ionic liquid electrode
    Yonghong Li
    Xiaoying Liu
    Xiandong Zeng
    Yong Liu
    Xinsheng Liu
    Wanzhi Wei
    Shenglian Luo
    [J]. Microchimica Acta, 2009, 165 : 393 - 398
  • [8] Nonenzymatic hydrogen peroxide sensor based on a Prussian Blue-modified carbon ionic liquid electrode
    Li, Yonghong
    Liu, Xiaoying
    Zeng, Xiandong
    Liu, Yong
    Liu, Xinsheng
    Wei, Wanzhi
    Luo, Shenglian
    [J]. MICROCHIMICA ACTA, 2009, 165 (3-4) : 393 - 398
  • [9] Porous anodic alumina electrode modified with a thin film of Prussian blue: Application to amperometric detection of hydrogen peroxide
    Xu, Guorong
    Ren, Fenglian
    Si, Shihui
    Yi, Qingfeng
    [J]. CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2006, 51 (05): : 234 - 243
  • [10] Amperometric detection of morphine at a Prussian blue-modified indium tin oxide electrode
    Ho, KC
    Chen, CY
    Hsu, HC
    Chen, LC
    Shiesh, SC
    Lin, XZ