Amperometric detection of hydrogen peroxide at a Prussian Blue-modified FTO electrode

被引:65
|
作者
Tseng, KS
Chen, LC
Ho, KC [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem Engn, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Inst Polymer Sci & Engn, Taipei 10617, Taiwan
关键词
FTO; hydrogen peroxide; modified electrode; Prussian blue; H2O2; sensor;
D O I
10.1016/j.snb.2004.12.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research focuses on the use of a Prussian Blue (PB)-modified optically transparent electrode for sensing hydrogen peroxide (H2O2). The PB thin films were deposited galvanostatically onto F-doped tin oxide (FTO) glass substrates. Then a reliable and reproducible detection was achieved by exerting a constant bias of -0.2 V (versus Ag/AgCl/saturated KCl) at the PB-modified FTO electrode immersed in an H2O2 solution containing 0.1 M KCl, pH 2. The dynamic range of detection was found to lie between 50 mu M and 50 mM, and the sensitivity was ca. 58.1 mA/cm(2) M. But it was also observed that the dissolved oxygen interfered the H2O2 sensing. Better sensing results could be obtained if the solution was pre-purged with N-2. To sum up, this study possesses the potential to eliminate the use of costly platinum or glassy carbon in a PB-based H2O2 sensor and may provide the basis for optical sensing. (c) 2004 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:738 / 745
页数:8
相关论文
共 50 条
  • [1] Prussian blue-modified nanoporous gold film electrode for amperometric determination of hydrogen peroxide
    Ghaderi, Seyran
    Mehrgardi, Masoud Ayatollahi
    BIOELECTROCHEMISTRY, 2014, 98 : 64 - 69
  • [2] Kinetic characterization of Prussian Blue-modified graphite electrodes for amperometric detection of hydrogen peroxide
    Cretu, Raluca C.
    Gligor, Delia M.
    Muresan, Laura
    Popescu, Ionel Catalin
    Muresan, Liana M.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2006, 36 (12) : 1327 - 1332
  • [3] Kinetic characterization of Prussian Blue-modified graphite electrodes for amperometric detection of hydrogen peroxide
    Raluca C. Cretu
    Delia M. Gligor
    Laura Muresan
    Ionel Catalin Popescu
    Liana M. Muresan
    Journal of Applied Electrochemistry, 2006, 36 : 1327 - 1332
  • [4] Amperometric detection of morphine at a Prussian blue-modified indium tin oxide electrode
    Ho, KC
    Chen, CY
    Hsu, HC
    Chen, LC
    Shiesh, SC
    Lin, XZ
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (01): : 3 - 8
  • [5] Development of a Prussian blue-modified electrochemical sensor for the detection of hydrogen peroxide
    Budner, Drew M.
    Hauck, John
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237 : 316 - 316
  • [6] Prussian blue-modified laser-induced graphene platforms for detection of hydrogen peroxide
    Tiago A. Matias
    Lucas V. de Faria
    Raquel G. Rocha
    Murillo N. T. Silva
    Edson Nossol
    Eduardo M. Richter
    Rodrigo A. A. Muñoz
    Microchimica Acta, 2022, 189
  • [7] Amperometric thiol sensor based on Prussian blue-modified glassy carbon electrode
    Kafi, A. K. M.
    Yin, Fan
    Shin, Hoon-Kyu
    Kwon, Young-Soo
    CURRENT APPLIED PHYSICS, 2007, 7 (05) : 496 - 499
  • [8] Nonenzymatic hydrogen peroxide sensor based on a Prussian Blue-modified carbon ionic liquid electrode
    Yonghong Li
    Xiaoying Liu
    Xiandong Zeng
    Yong Liu
    Xinsheng Liu
    Wanzhi Wei
    Shenglian Luo
    Microchimica Acta, 2009, 165 : 393 - 398
  • [9] Nonenzymatic hydrogen peroxide sensor based on a Prussian Blue-modified carbon ionic liquid electrode
    Li, Yonghong
    Liu, Xiaoying
    Zeng, Xiandong
    Liu, Yong
    Liu, Xinsheng
    Wei, Wanzhi
    Luo, Shenglian
    MICROCHIMICA ACTA, 2009, 165 (3-4) : 393 - 398
  • [10] Prussian blue-modified laser-induced graphene platforms for detection of hydrogen peroxide
    Matias, Tiago A.
    de Faria, Lucas, V
    Rocha, Raquel G.
    Silva, Murillo N. T.
    Nossol, Edson
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    MICROCHIMICA ACTA, 2022, 189 (05)