Advanced CEX surface chemistry for flow-through MAb aggregate clearance

被引:0
|
作者
Cataldo, William [1 ]
Hamzik, James [1 ]
Kozlov, Mikhail [1 ]
Potty, Ajish [1 ]
Umana, Joaquin [1 ]
机构
[1] EMD Millipore, Bedford, MA 01730 USA
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
15-BIOT
引用
收藏
页数:1
相关论文
共 50 条
  • [31] Determination of carbaryl in natural water samples by a surface plasmon resonance flow-through immunosensor
    Mauriz, E
    Calle, A
    Abad, A
    Montoya, A
    Hildebrandt, A
    Barceló, D
    Lechuga, LM
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (11): : 2129 - 2136
  • [32] Multiphysics modeling of flow-through advanced oxidation photoreactors with in-situ hydrogen peroxide electrogeneration
    Montazeri, Mahyar Mohaghegh
    Hejazi, Seyyed Arman
    Taghipour, Fariborz
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2023, 11 (03):
  • [33] Evaluation of flow-through hydrophobic interaction and hydroxyapatite chromatography steps for the removal of aggregates in the purification of monoclonal antibody TBL-mAb-01
    Evans, William
    Chakrabarti, Atis
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [34] FLOW-INJECTION ANALYSIS OF TRACE FREE CYANIDE IN SURFACE GROUND WATERS WITH AN AMPEROMETRIC FLOW-THROUGH DETECTOR
    MA, HC
    JIN, L
    YAN, HY
    KEXUE TONGBAO, 1983, 28 (08): : 1145 - 1145
  • [35] Anion exchange membrane adsorbers for flow-through polishing steps: Part I. clearance of minute virus of mice
    Weaver, Justin
    Husson, Scott M.
    Murphy, Louise
    Wickramasinghe, S. Ranil
    BIOTECHNOLOGY AND BIOENGINEERING, 2013, 110 (02) : 491 - 499
  • [36] Use of Surface Enhanced Blocking (SEB) Electrodes for Microbial Cell Lysis in Flow-Through Devices
    Talebpour, Abdossamad
    Maaskant, Robert
    Khine, Aye Aye
    Alavie, Tino
    PLOS ONE, 2014, 9 (07):
  • [37] Resolution of Biparametric Mixtures Using Bead Injection Spectroscopic Flow-through Renewable Surface Sensors
    M. J. Ruedas-Rama
    A. Ruiz-Medina
    A. Molina-Díaz
    Analytical Sciences, 2005, 21 : 1079 - 1084
  • [38] Lectin binding studies on a glycopolymer brush flow-through biosensor by localized surface plasmon resonance
    Ruben R. Rosencrantz
    Vu Hoa Nguyen
    Hyunji Park
    Christine Schulte
    Alexander Böker
    Uwe Schnakenberg
    Lothar Elling
    Analytical and Bioanalytical Chemistry, 2016, 408 : 5633 - 5640
  • [39] Lectin binding studies on a glycopolymer brush flow-through biosensor by localized surface plasmon resonance
    Rosencrantz, Ruben R.
    Vu Hoa Nguyen
    Park, Hyunji
    Schulte, Christine
    Boeker, Alexander
    Schnakenberg, Uwe
    Elling, Lothar
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (20) : 5633 - 5640
  • [40] Surface enhanced Raman spectroscopy as a molecular specific detection system in aqueous flow-through systems
    Weissenbacher, N
    Lendl, B
    Frank, J
    Wanzenböck, HD
    Kellner, R
    ANALYST, 1998, 123 (05) : 1057 - 1060