A new, sensitive and simple bead injection spectroscopy-flow injection analysis (BIS-FIA) sensor with spectrophotometric detection, using a commercially available flow-cell, is described to the determination of biparametric mixtures. As an analytical model, the metallic mixture Cu(II) and Zn(II) has been chosen. The flow-cell (Hellma 138-OS) is filled by injecting in the flow system 300 μl of a homogeneous bead suspension of an anion exchanger gel (Sephadex QAE A-25) previously loaded with the chromogenic reagent 2-carboxyl-2-hydroxy-5-sulfoformazylbenzene (Zincon). A sequential reaction of Cu(II) and Zn(II) with Zincon to form two complexes is performed on the bead sensing support and the absorbance is monitored at 627 nm, after two successive injections from the mixture solution. The sample containing these metal ions is injected into the first carrier (deionized water, pH 5.9), and Cu(II) selectively reacts with Zincon on the beads, developing the analytical signal. Then, 600 μl of 2 M HCl is injected to decompose the complex, and the carrier solution is changed. At pH 11 (second carrier) both Cu(II) and Zn(II) react with the chromogenic reagent, the absorbance now corresponding to both analytes. The eluent is again injected to descompose both complexes. After three analyses the sensing bead surface is not regenerated. Then, beads are automatically discarded from the flow cell by reversal of the flow, and instantaneously transported out of the system. So the procedure exploits the combination of the concepts of flow-through renewable sensors with Bead Injection Spectroscopy. Using a sample volume of 1000 μl, the calibration graph for Cu(II) is linear over the range 0.05 to 1 μg ml-1 and for Zn(II) from 0.1 to 1.8 μg ml-1 in the presence of each other. RSDs (%) lower than 5% are obtained for both analytes. The sensor is satisfactorily applied to individual determination or mixture resolution in waters, pharmaceuticals, soils and human hair samples.
引用
收藏
页码:1079 / 1084
页数:5
相关论文
共 39 条
  • [1] Resolution of biparametric mixtures using bead injection spectroscopic flow-through renewable surface sensors
    Ruedas-Rama, MJ
    Ruiz-Medina, A
    Molina-Díaz, A
    ANALYTICAL SCIENCES, 2005, 21 (09) : 1079 - 1084
  • [2] Bead injection spectroscopic flow-through renewable surface sensors with commercial flow cells as an alternative to reusable flow-through sensors
    Rama, MJR
    Medina, AR
    Díaz, AM
    ANALYTICA CHIMICA ACTA, 2003, 482 (02) : 209 - 217
  • [3] Implementation of flow-through multi-sensors with bead injection spectroscopy:: fluorimetric renewable surface biparameter sensor for determination of berillium and aluminum
    Rama, MJR
    Medina, AR
    Díaz, AM
    TALANTA, 2004, 62 (05) : 879 - 886
  • [4] INJECTION TECHNIQUES IN DYNAMIC FLOW-THROUGH ANALYSIS WITH ELECTROANALYTICAL SENSORS
    PUNGOR, E
    FEHER, Z
    NAGY, G
    TOTH, K
    HORVAI, G
    GRATZL, M
    ANALYTICA CHIMICA ACTA, 1979, 109 (01) : 1 - 24
  • [5] INJECTION TECHNIQUE AS A NEW APPROACH FOR DYNAMIC FLOW-THROUGH ANALYSIS WITH ELECTROANALYTICAL SENSORS
    PUNGOR, E
    FEHER, Z
    NAGY, G
    TOTH, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 176 (SEP): : 72 - 72
  • [6] New flow-through coulometric detector with renewable working electrode material for flow injection analysis and HPLC
    Mika, Jan
    Barek, Jiri
    Zima, Jiri
    Dejmkova, Hana
    ELECTROCHIMICA ACTA, 2015, 154 : 397 - 403
  • [7] SENSITIVITY ENHANCEMENT BY USING AN HPLC FLOW-THROUGH SENSOR FOR DETERMINATION OF PESTICIDE MIXTURES
    TENA, MT
    DECASTRO, MDL
    VALCARCEL, M
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (13): : 2373 - 2383
  • [8] A Prussian blue-based flow-through renewable surface optosensor for analysis of ascorbic acid
    Rama, MJR
    Medina, AR
    Díaz, AM
    MICROCHEMICAL JOURNAL, 2004, 78 (02) : 157 - 162
  • [9] Determination of immunoglobulin G in human serum by sequential injection renewable surface fluorescence immunoassay system with a chip-based flow-through cell
    Zhu, HL
    Chen, HW
    Zhou, YL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (07) : 841 - 846
  • [10] FLOW-INJECTION ANALYSIS OF TRACE FREE CYANIDE IN SURFACE GROUND WATERS WITH AN AMPEROMETRIC FLOW-THROUGH DETECTOR
    MA, HC
    JIN, L
    YAN, HY
    KEXUE TONGBAO, 1983, 28 (08): : 1145 - 1145