摘要
Objective: To evaluate dose performance and image quality of 64-slice dual source CT(DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates (<70 bpm), image quality of SSCT was equivalent to that of DSCT (P>0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P<0.05). The average effective dose of SSCT was 9.3 +/- 0.9 mSv at low heart rates (<70 bpm) while, the average estimated effective doses of DSCT were 9.1 +/- 1.3 mSv, 8.3 +/- 1.1 mSv, 7.9 +/- 1.1 mSv, 6.9 +/- 0.7 mSv, and 5.9 +/- 1.3 mSv, corresponding to heart rates of 50-59 bpm, 60-69 bpm, 70-79 bpm, 80-89 bpm, and 90-100 bpm. Conclusion: For cardiac CTA, both DSCT and SSCT can get good image quality at low heart rates (<70 bpm) with a similar radiation dose, but, at high heart rates (>70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:396 / 400
页数:5
相关论文
共 50 条
  • [1] Dual-Source Versus Single-Source Cardiac CT Angiography: Comparison of Diagnostic Image Quality
    Donnino, Robert
    Jacobs, Jill E.
    Doshi, Jay V.
    Hecht, Elizabeth M.
    Kim, Danny C.
    Babb, James S.
    Srichai, Monvadi B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : 1051 - 1056
  • [2] Coronary CT angiography using a prospective protocol. Comparison of image quality and radiation dose between dual source CT and single source CT
    Duarte, R.
    Miranda, D.
    Fernandez-Perez, G.
    Costa, J. C.
    RADIOLOGIA, 2013, 55 (04): : 315 - 322
  • [3] Comparison of radiation dose, contrast enhancement and image quality of prospective ECG-Gated CT coronary angiography: Single versus dual source CT
    Liang, C. R.
    Ong, C. C.
    Chai, P.
    Teo, L. L. S.
    RADIOGRAPHY, 2021, 27 (03) : 831 - 839
  • [4] Image Quality and Radiation Dose for Prospectively Triggered Coronary CT Angiography: 128-Slice Single-Source CT versus First-Generation 64-Slice Dual-Source CT
    Jin Gu
    He-shui Shi
    Ping Han
    Jie Yu
    Gui-na Ma
    Sheng Wu
    Scientific Reports, 6
  • [5] Image Quality and Radiation Dose for Prospectively Triggered Coronary CT Angiography: 128-Slice Single-Source CT versus First-Generation 64-Slice Dual-Source CT
    Gu, Jin
    Shi, He-shui
    Han, Ping
    Yu, Jie
    Ma, Gui-na
    Wu, Sheng
    SCIENTIFIC REPORTS, 2016, 6
  • [6] Radiation dose for cardiac CT angiography - A comparison between dual source and 64-slice CT
    Hermann, Franziska
    Meyer, Tanja
    Hadamitzky, Martin
    Hendrich, Eva
    Lang, Ute
    Schwarzer, Christine
    Martinoff, Stefan
    Hausleiter, Joerg
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A142 - A142
  • [7] Radiation Dose at Coronary CT Angiography: Second-Generation Dual-Source CT Versus Single-Source 64-MDCT and First-Generation Dual-Source CT
    Fink, Christian
    Krissak, Radko
    Henzler, Thomas
    Lechel, Ursula
    Brix, Gunnar
    Takx, Richard A. P.
    Nance, John W.
    Abro, Joseph A.
    Schoenberg, Stefan O.
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) : W550 - W557
  • [8] Multiphase CT angiography versus single-phase CT angiography: Comparison of image quality and radiation dose
    Yang, C. -Y.
    Chen, Y. -F.
    Lee, C. -W.
    Huang, A.
    Shen, Y.
    Wei, C.
    Liu, H. -M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (07) : 1288 - 1295
  • [9] Author Correction: Image Quality and Radiation Dose for Prospectively Triggered Coronary CT Angiography: 128-Slice Single-Source CT versus First-Generation 64-Slice Dual-Source CT
    Jin Gu
    He-shui Shi
    Ping Han
    Jie Yu
    Gui-na Ma
    Sheng Wu
    Scientific Reports, 10
  • [10] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786