摘要
The aim of this study was to calculate microdosimetric distributions for low energy electrons simulated using the Monte Carlo track structure code Geant4-DNA. Tracks for monoenergetic electrons with kinetic energies ranging from 100 eV to 1 MeV were simulated in an infinite spherical water phantom using the Geant4-DNA extension included in Geant4 toolkit version 10.2 (patch 02). The microdosimetric distributions were obtained through random sampling of transfer points and overlaying scoring volumes within the associated volume of the tracks. Relative frequency distributions of energy deposition f(>E)/f(>0) and dose mean lineal energy ((y) over barD) values were calculated in nanometer-sized spherical and cylindrical targets. The effects of scoring volume and scoring techniques were examined. The results were compared with published data generated using MOCA8B and KURBUC. Geant4-DNA produces a lower frequency of higher energy deposits than MOCA8B. The (y) over barD values calculated with Geant4-DNA are smaller than those calculated using MOCA8B and KURBUC. The differences are mainly due to the lower ionization and excitation cross sections of Geant4-DNA for low energy electrons. To a lesser extent, discrepancies can also be attributed to the implementation in this study of a new and fast scoring technique that differs from that used in previous studies. For the same mean chord length ((l) over bar), the (y) over barD calculated in cylindrical volumes are larger than those calculated in spherical volumes. The discrepancies due to cross sections and scoring geometries increase with decreasing scoring site dimensions. A new set of (y) over barD values has been presented for monoenergetic electrons using a fast track sampling algorithm and the most recent physics models implemented in Geant4-DNA. This dataset can be combined with primary electron spectra to predict the radiation quality of photon and electron beams.
引用
收藏
页码:5495 / 5508
页数:14
相关论文
共 50 条
  • [31] Comparison of nanodosimetric parameters of track structure calculated by the Monte Carlo codes Geant4-DNA and PTra
    Lazarakis, P.
    Bug, M. U.
    Gargioni, E.
    Guatelli, S.
    Rabus, H.
    Rosenfeld, A. B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05): : 1231 - 1250
  • [32] Realistic single-cell geometry model: Cellular S-value calculations with Geant4, Geant4-DNA and PENELOPE
    Falzone, N.
    Freudenberg, R.
    Fernandez-Varea, J. M.
    Malcolm, J.
    Able, S.
    Vallis, K. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S401 - S401
  • [33] The effects of cell displacement on DNA damages in targeted radiation therapy using Geant4-DNA
    Ganjgah, Ali Azizi
    Taherparvar, Payvand
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [34] The impact of new Geant4-DNA cross section models on electron track structure simulations in liquid water
    Kyriakou, I.
    Sefl, M.
    Nourry, V.
    Incerti, S.
    JOURNAL OF APPLIED PHYSICS, 2016, 119 (19)
  • [35] Track structure modeling in liquid water: A review of the Geant4-DNA very low energy extension of the Geant4 Monte Carlo simulation toolkit
    Bernal, M. A.
    Bordage, M. C.
    Brown, J. M. C.
    Davidkova, M.
    Delage, E.
    El Bitar, Z.
    Enger, S. A.
    Francis, Z.
    Guatelli, S.
    Ivanchenko, V. N.
    Karamitros, M.
    Kyriakou, I.
    Maigne, L.
    Meylan, S.
    Murakami, K.
    Okada, S.
    Payno, H.
    Perrot, Y.
    Petrovic, I.
    Pham, Q. T.
    Ristic-Fira, A.
    Sasaki, T.
    Stepan, V.
    Tran, H. N.
    Villagrasa, C.
    Incerti, S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 861 - 874
  • [36] Simulation of early DNA damage after the irradiation of a fibroblast cell nucleus using Geant4-DNA
    Meylan, Sylvain
    Incerti, Sebastien
    Karamitros, Mathieu
    Tang, Nicolas
    Bueno, Marta
    Clairand, Isabelle
    Villagrasa, Carmen
    SCIENTIFIC REPORTS, 2017, 7
  • [37] Microdosimetric evaluation of intermediate-energy brachytherapy sources using Geant4-DNA
    Famulari, G.
    Pater, P.
    Enger, S. A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S192 - S192
  • [38] Investigate the radiation-induced damage on an atomistic DNA model by using Geant4-DNA toolkit
    Chen, Junliang
    Yun, Sujun
    Dong, Tiekuang
    Ren, Zhongzhou
    Zhang, Xiaoping
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2021, 494-495 : 59 - 67
  • [39] Investigation of the direct DNA damages irradiated by protons of different energies using geant4-DNA toolkit
    Ganjeh, Z. Ahmadi
    Eslami-Kalantari, M.
    Loushab, M. Ebrahimi
    Mowlavi, A. A.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (04): : 809 - 815
  • [40] Calculation of direct DNA damages by a new approach for carbon ions and protons using Geant4-DNA
    Ganjeh, Zahra Ahmadi
    Eslami-Kalantari, Mohammad
    Loushab, Mahdy Ebrahimi
    Mowlavi, Ali Asghar
    RADIATION PHYSICS AND CHEMISTRY, 2021, 179