Microdosimetry calculations for monoenergetic electrons using Geant4-DNA combined with a weighted track sampling algorithm

被引:27
|
作者
Famulari, Gabriel [1 ]
Pater, Piotr [1 ]
Enger, Shirin A. [1 ,2 ,3 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ H4A 3J1, Canada
[2] McGill Univ, Dept Oncol, Montreal, PQ H4A 3J1, Canada
[3] McGill Univ, Hlth Ctr, Res Inst, Montreal, PQ H3H 2L9, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 13期
基金
加拿大自然科学与工程研究理事会;
关键词
microdosimetry; lineal energy; Geant4-DNA; Monte Carlo; track structure simulations; ENERGY DEPOSITION; LIQUID WATER; RADIATION PROTECTION; TARGETS; QUALITY; NANODOSIMETRY; EXTENSION; MODELS;
D O I
10.1088/1361-6560/aa71f6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to calculate microdosimetric distributions for low energy electrons simulated using the Monte Carlo track structure code Geant4-DNA. Tracks for monoenergetic electrons with kinetic energies ranging from 100 eV to 1 MeV were simulated in an infinite spherical water phantom using the Geant4-DNA extension included in Geant4 toolkit version 10.2 (patch 02). The microdosimetric distributions were obtained through random sampling of transfer points and overlaying scoring volumes within the associated volume of the tracks. Relative frequency distributions of energy deposition f(>E)/f(>0) and dose mean lineal energy ((y) over barD) values were calculated in nanometer-sized spherical and cylindrical targets. The effects of scoring volume and scoring techniques were examined. The results were compared with published data generated using MOCA8B and KURBUC. Geant4-DNA produces a lower frequency of higher energy deposits than MOCA8B. The (y) over barD values calculated with Geant4-DNA are smaller than those calculated using MOCA8B and KURBUC. The differences are mainly due to the lower ionization and excitation cross sections of Geant4-DNA for low energy electrons. To a lesser extent, discrepancies can also be attributed to the implementation in this study of a new and fast scoring technique that differs from that used in previous studies. For the same mean chord length ((l) over bar), the (y) over barD calculated in cylindrical volumes are larger than those calculated in spherical volumes. The discrepancies due to cross sections and scoring geometries increase with decreasing scoring site dimensions. A new set of (y) over barD values has been presented for monoenergetic electrons using a fast track sampling algorithm and the most recent physics models implemented in Geant4-DNA. This dataset can be combined with primary electron spectra to predict the radiation quality of photon and electron beams.
引用
收藏
页码:5495 / 5508
页数:14
相关论文
共 50 条
  • [21] Nanoscale Proton Dose Distributions Using GEANT4-DNA Simulation
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [22] Stopping power and ranges of electrons, protons and alpha particles in liquid water using the Geant4-DNA package
    Francis, Z.
    Incerti, S.
    Karamitros, M.
    Tran, H. N.
    Villagrasa, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (20): : 2307 - 2311
  • [23] Monte Carlo simulations of microdosimetry and radiolytic species production at long time post proton irradiation using GATE and Geant4-DNA
    Fois, Giovanna Rosa
    Tran, Hoang Ngoc
    Fiegel, Vincent
    Blain, Guillaume
    Chiavassa, Sophie
    Craff, Emeline
    Delpon, Gregory
    Evin, Manon
    Haddad, Ferid
    Incerti, Sebastien
    Koumeir, Charbel
    Metivier, Vincent
    Mouchard, Quentin
    Poirier, Freddy
    Potiron, Vincent
    Servagent, Noel
    Vandenborre, Johan
    Maigne, Lydia
    MEDICAL PHYSICS, 2024, 51 (10) : 7500 - 7510
  • [24] Spatial-temporal tracking of molecular species in Geant4-DNA track structure simulations
    Velten, Christian
    Tome, Wolfgang A.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [25] Implementation of new physics models for low energy electrons in liquid water in Geant4-DNA
    Bordage, M. C.
    Bordes, J.
    Edel, S.
    Terrissol, M.
    Franceries, X.
    Bardies, M.
    Lampe, N.
    Incerti, S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1833 - 1840
  • [26] Assessing DNA damage and relative biological effectiveness of the secondary electrons in gadolinium neutron capture therapy using an adapted Geant4-DNA
    Yu, Weiyue
    Pang, Yongqiang
    Ji, Taotao
    Lu, Peng
    Liang, Lizhen
    Hu, Chundong
    Hu, Zhimeng
    Hong, Bing
    Chen, Ni
    RADIATION PHYSICS AND CHEMISTRY, 2024, 218
  • [27] Molecular scale track structure simulations in liquid water using the Geant4-DNA Monte-Carlo processes
    Francis, Z.
    Incerti, S.
    Capra, R.
    Mascialino, B.
    Montarou, G.
    Stepan, V.
    Villagrasa, C.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (01) : 220 - 226
  • [28] Simulation of DNA damage using Geant4-DNA: an overview of the "molecularDNA" example application
    Chatzipapas, Konstantinos P.
    Tran, Ngoc Hoang
    Dordevic, Milos
    Zivkovic, Sara
    Zein, Sara
    Shin, Wook-Geun
    Sakata, Dousatsu
    Lampe, Nathanael
    Brown, Jeremy M. C.
    Ristic-Fira, Aleksandra
    Petrovic, Ivan
    Kyriakou, Ioanna
    Emfietzoglou, Dimitris
    Guatelli, Susanna
    Incerti, Sebastien
    PRECISION RADIATION ONCOLOGY, 2023, 7 (01): : 4 - 14
  • [29] Geant4-DNA simulations using complex DNA geometries generated by the DnaFabric tool
    Meylan, S.
    Vimont, U.
    Incerti, S.
    Clairand, I.
    Villagrasa, C.
    COMPUTER PHYSICS COMMUNICATIONS, 2016, 204 : 159 - 169
  • [30] Microdosimetry of electrons in liquid water using the low-energy models of Geant4
    Kyriakou, I.
    Emfietzoglou, D.
    Ivanchenko, V.
    Bordage, M. C.
    Guatelli, S.
    Lazarakis, P.
    Tran, H. N.
    Incerti, S.
    JOURNAL OF APPLIED PHYSICS, 2017, 122 (02)