Microdosimetry calculations for monoenergetic electrons using Geant4-DNA combined with a weighted track sampling algorithm

被引:27
|
作者
Famulari, Gabriel [1 ]
Pater, Piotr [1 ]
Enger, Shirin A. [1 ,2 ,3 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ H4A 3J1, Canada
[2] McGill Univ, Dept Oncol, Montreal, PQ H4A 3J1, Canada
[3] McGill Univ, Hlth Ctr, Res Inst, Montreal, PQ H3H 2L9, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 13期
基金
加拿大自然科学与工程研究理事会;
关键词
microdosimetry; lineal energy; Geant4-DNA; Monte Carlo; track structure simulations; ENERGY DEPOSITION; LIQUID WATER; RADIATION PROTECTION; TARGETS; QUALITY; NANODOSIMETRY; EXTENSION; MODELS;
D O I
10.1088/1361-6560/aa71f6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to calculate microdosimetric distributions for low energy electrons simulated using the Monte Carlo track structure code Geant4-DNA. Tracks for monoenergetic electrons with kinetic energies ranging from 100 eV to 1 MeV were simulated in an infinite spherical water phantom using the Geant4-DNA extension included in Geant4 toolkit version 10.2 (patch 02). The microdosimetric distributions were obtained through random sampling of transfer points and overlaying scoring volumes within the associated volume of the tracks. Relative frequency distributions of energy deposition f(>E)/f(>0) and dose mean lineal energy ((y) over barD) values were calculated in nanometer-sized spherical and cylindrical targets. The effects of scoring volume and scoring techniques were examined. The results were compared with published data generated using MOCA8B and KURBUC. Geant4-DNA produces a lower frequency of higher energy deposits than MOCA8B. The (y) over barD values calculated with Geant4-DNA are smaller than those calculated using MOCA8B and KURBUC. The differences are mainly due to the lower ionization and excitation cross sections of Geant4-DNA for low energy electrons. To a lesser extent, discrepancies can also be attributed to the implementation in this study of a new and fast scoring technique that differs from that used in previous studies. For the same mean chord length ((l) over bar), the (y) over barD calculated in cylindrical volumes are larger than those calculated in spherical volumes. The discrepancies due to cross sections and scoring geometries increase with decreasing scoring site dimensions. A new set of (y) over barD values has been presented for monoenergetic electrons using a fast track sampling algorithm and the most recent physics models implemented in Geant4-DNA. This dataset can be combined with primary electron spectra to predict the radiation quality of photon and electron beams.
引用
收藏
页码:5495 / 5508
页数:14
相关论文
共 50 条
  • [1] Evaluation of the Dose Enhancement with Gold Nanoparticle in Microdosimetry Level Using the Geant4-DNA Toolkit
    He, C.
    Chow, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3674 - 3674
  • [2] Microdosimetry and Dose-Averaged LET Calculations of Protons in Liquid Water: A Novel Geant4-DNA Application
    Baratto-Roldan, Anna
    Bertolet, Alejandro
    Baiocco, Giorgio
    Carabe, Alejandro
    Cortes-Giraldo, Miguel Antonio
    FRONTIERS IN PHYSICS, 2021, 9
  • [3] Geant4-DNA example applications for track structure simulations in liquid water: A report from the Geant4-DNA Project
    Incerti, S.
    Kyriakou, I.
    Bernal, M. A.
    Bordage, M. C.
    Francis, Z.
    Guatelli, S.
    Ivanchenko, V.
    Karamitros, M.
    Lampe, N.
    Lee, S. B.
    Meylan, S.
    Min, C. H.
    Shin, W. G.
    Nieminen, P.
    Sakata, D.
    Tang, N.
    Villagrasa, C.
    Tran, H. N.
    Brown, J. M. C.
    MEDICAL PHYSICS, 2018, 45 (08) : E722 - E739
  • [4] Electron track structure simulations in a gold nanoparticle using Geant4-DNA
    Sakata, Dousatsu
    Kyriakou, Ioanna
    Hoang N Tran
    Bordage, Marie-Claude
    Rosenfeld, Anatoly
    Ivanchenko, Vladimir
    Incerti, Sebastien
    Emfietzoglou, Dimitris
    Guatelli, Susanna
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 63 : 98 - 104
  • [5] Calculation of microdosimetric spectra for protons using Geant4-DNA and a μ-randomness sampling algorithm for the nanometric structures
    Mokari, Mojtaba
    Moeini, Hossein
    Soleimani, Marzieh
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2021, 97 (02) : 208 - 218
  • [6] Microdosimetric calculations of the direct DNA damage induced by low energy electrons using the Geant4-DNA Monte Carlo code
    Margis, Stefanos
    Magouni, Maria
    Kyriakou, Ioanna
    Georgakilas, Alexandros G.
    Incerti, Sebastien
    Emfietzoglou, Dimitris
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (04):
  • [7] Microdosimetry of the Auger electron emitting 123I radionuclide using Geant4-DNA simulations
    Fourie, H.
    Newman, R. T.
    Slabbert, J. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08): : 3333 - 3346
  • [8] Track structure simulation of low energy electron damage to DNA using Geant4-DNA
    Mokari, Mojtaba
    Alamatsaz, Mohammad Hassan
    Moeini, Hossein
    Babaei-Brojeny, Ali Akbar
    Taleei, Reza
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (06):
  • [9] Estimation of produced oxygens in the track of heavy-ion using Geant4-DNA
    Hirano, Yoshiyuki
    Aso, Tsukasa
    Horii, Yoshuya
    JOURNAL OF ADVANCED SIMULATION IN SCIENCE AND ENGINEERING, 2024, 11 (01): : 207 - 221
  • [10] Validation of Geant4-DNA/TOPAS-NBio Simulations of Water Radiolysis Induced with Monoenergetic Electrons, Protons and Alpha Particles
    Ramos-Mendez, J.
    Perl, J.
    Schuemann, J.
    Paganetti, H.
    McNamara, A.
    Held, K.
    Faddegon, B.
    MEDICAL PHYSICS, 2017, 44 (06) : 2979 - 2979