Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery

被引:6
|
作者
Okamura, Hideo [1 ]
Padmanabhan, Deepak [1 ]
Watson, Robert E., Jr. [2 ]
Dalzell, Connie [1 ]
Acker, Nancy [1 ]
Jondal, Mary [1 ]
Romme, Abby L. [1 ]
Cha, Yong-mei [1 ]
Asirvatham, Samuel J. [1 ]
Felmlee, Joel P. [2 ]
Friedman, Paul A. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN USA
[2] Mayo Clin, Div Diagnost Radiol, Rochester, MN USA
来源
关键词
pacemaker; ICD; MRI; ERI; depleted battery;
D O I
10.1111/pace.13042
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundMagnetic resonance imaging (MRI) in patients with non-MRI-conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported. MethodsProspective data were collected between January 2008 and May 2015 in patients with non-MRI-conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events. ResultsMRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power-on-reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005. ConclusionPatients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing.
引用
收藏
页码:476 / 481
页数:6
相关论文
共 50 条
  • [31] Magnetic Resonance Imaging in Patients With Temporary Screw-In Pacemakers
    Haq, Ikram U.
    Mcgee, Kiaran P.
    Collins, Jeremy D.
    Olson, Nora E.
    Mulpuru, Siva K.
    Cha, Yong-Mei
    Friedman, Paul A.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (07) : 1184 - 1186
  • [32] Safety, feasibility, and diagnostic value of cardiac magnetic resonance imaging in patients with cardiac pacemakers and implantable cardioverters/defibrillators at 1.5 T
    Naehle, Claas P.
    Kreuz, Jens
    Strach, Katharina
    Schwab, Joerg Otto
    Pingel, Simon
    Luechinger, Roger
    Fimmers, Rolf
    Schild, Hans
    Thomas, Daniel
    AMERICAN HEART JOURNAL, 2011, 161 (06) : 1096 - 1105
  • [33] Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restrictions
    Mollerus, Michael
    Albin, Glenn
    Lipinski, Margaret
    Lucca, Jill
    EUROPACE, 2010, 12 (07): : 947 - 951
  • [34] Feasibility of adenosine stress cardiovascular magnetic resonance perfusion imaging in patients with MR-conditional transvenous permanent pacemakers and defibrillators
    Pavon, Anna Giulia
    Porretta, Alessandra Pia
    Arangalage, Dimitri
    Domenichini, Giulia
    Rutz, Tobias
    Hugelshofer, Sarah
    Pruvot, Etienne
    Monney, Pierre
    Pascale, Patrizio
    Schwitter, Juerg
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2022, 24 (01)
  • [35] SAFETY OUTCOMES IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS AND PERMANENT PACEMAKERS UNDERGOING MAGNETIC RESONANCE IMAGING AT 1.5-TESLA
    Vatthyam, Roshan
    Cantrell, Matthew
    Elliott, Michael D.
    Fogel, Richard I.
    Prystowsky, Eric N.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [36] Cardiac pacemakers and implantable cardioverter defibrillators:: In vitro magnetic resonance imaging evaluation at 1.5-Tesla
    Shellock, Frank G.
    Fischer, Laura
    Fieno, David S.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (01) : 21 - 31
  • [37] Feasibility of adenosine stress cardiovascular magnetic resonance perfusion imaging in patients with MR-conditional transvenous permanent pacemakers and defibrillators
    Anna Giulia Pavon
    Alessandra Pia Porretta
    Dimitri Arangalage
    Giulia Domenichini
    Tobias Rutz
    Sarah Hugelshofer
    Etienne Pruvot
    Pierre Monney
    Patrizio Pascale
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 24
  • [38] Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restriction
    Mollerus, M.
    Albin, G.
    Lipinski, M.
    Lucca, J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 130 - 130
  • [39] Can patients with implanted pacemakers/ICD undergo magnetic resonance imaging?
    Sermasi, S.
    Marconi, M.
    Mezzetti, M.
    Piovaccari, G.
    CARDIAC ARRHYTHMIAS 2005, 2005, : 627 - 630
  • [40] Leadless pacemaker implantation in elderly patients with abandoned transvenous pacemakers with depleted batteries
    Frick, William
    Chen, Yongzhen
    Zamora, Lazarus
    Osman, Osama
    Hussein, Ahmed
    JOURNAL OF ARRHYTHMIA, 2023, 39 (04) : 638 - 640