Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery

被引:6
|
作者
Okamura, Hideo [1 ]
Padmanabhan, Deepak [1 ]
Watson, Robert E., Jr. [2 ]
Dalzell, Connie [1 ]
Acker, Nancy [1 ]
Jondal, Mary [1 ]
Romme, Abby L. [1 ]
Cha, Yong-mei [1 ]
Asirvatham, Samuel J. [1 ]
Felmlee, Joel P. [2 ]
Friedman, Paul A. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN USA
[2] Mayo Clin, Div Diagnost Radiol, Rochester, MN USA
来源
关键词
pacemaker; ICD; MRI; ERI; depleted battery;
D O I
10.1111/pace.13042
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundMagnetic resonance imaging (MRI) in patients with non-MRI-conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported. MethodsProspective data were collected between January 2008 and May 2015 in patients with non-MRI-conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events. ResultsMRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power-on-reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005. ConclusionPatients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing.
引用
收藏
页码:476 / 481
页数:6
相关论文
共 50 条
  • [1] SAFETY OF THORACIC MAGNETIC RESONANCE IMAGING IN PATIENTS WITH PACEMAKERS AND DEFIBRILLATORS
    Padmanabhan, Deepak
    Kella, Danesh
    Naksuk, Niyada
    Deshmukh, Abhishek
    Mulpuru, Siva
    Kapa, Suraj
    Mehta, Ramila
    Dalzell, Connie
    Olson, Nora
    Felmlee, Joel
    Jondal, Mary Lou
    Asirvatham, Samuel
    Watson, Robert
    Cha, Yong-Mei
    Friedman, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1599 - 1599
  • [2] Safety of thoracic magnetic resonance imaging for patients with pacemakers and defibrillators
    Padmanabhan, Deepak
    Kella, Danesh K.
    Deshmukh, Abhishek J.
    Mulpuru, Siva K.
    Mehta, Ramila A.
    Dalzell, Connie M.
    Olson, Nora E.
    Felmlee, Joel P.
    Jondal, Mary L.
    Asirvatham, Samuel J.
    Watson, Robert E., Jr.
    Cha, Yong-Mei
    Friedman, Paul A.
    HEART RHYTHM, 2019, 16 (11) : 1645 - 1651
  • [3] Magnetic Resonance Imaging in Patients With Implantable Cardioverter-Defibrillators and Pacemakers
    Roguin, Ariel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (06) : 556 - 557
  • [4] Outcomes after magnetic resonance imaging in patients with pacemakers and defibrillators and abandoned leads
    Morris, Michael F.
    Verma, Divya Ratan
    Sheikh, Hasaam
    Su, Wilber
    Pershad, Ashish
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (06) : 685 - 688
  • [5] Safety of magnetic resonance imaging in patients with legacy pacemakers and defibrillators and abandoned leads
    Padmanabhan, Deepak
    Kella, Danesh K.
    Mehta, Ramila
    Kapa, Suraj
    Deshmukh, Abhishek
    Mulpuru, Siva
    Jaffe, Allan S.
    Felmlee, Joel P.
    Jondal, Mary L.
    Dalzell, Connie M.
    Asirvatham, Samuel J.
    Cha, Yong-Mei
    Watson, Robert E., Jr.
    Friedman, Paul A.
    HEART RHYTHM, 2018, 15 (02) : 228 - 233
  • [6] Experiences of magnetic resonance imaging scanning in patients with pacemakers or implantable cardioverter-defibrillators
    Han, Donghoon
    Kang, Si-Hyuck
    Cho, Youngjin
    Oh, Il-Young
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2019, 34 (01): : 99 - +
  • [7] Magnetic resonance imaging in patients with pacemakers and implantable cardioverter-defibrillators: A systematic review
    Martins, R. -P.
    Baruteau, A. -E.
    Treguer, F.
    Cesari, O.
    Carsin-Nicol, B.
    Langella, B.
    Leclercq, C.
    Daubert, J. -C.
    Mabo, P.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2010, 59 (04): : 221 - 228
  • [8] Quantitative Assessment of Artifacts on Cardiac Magnetic Resonance Imaging of Patients with Pacemakers and Implantable Defibrillators
    Sasaki, Takeshi
    Hansford, Rozann
    Zviman, Menekhem M.
    Berger, Ronald D.
    Calkins, Hugh
    Bluemke, David A.
    Halperin, Henry R.
    Nazarian, Saman
    CIRCULATION, 2010, 122 (21)
  • [9] Determining the Risks of Magnetic Resonance Imaging at 1.5 Tesla for Patients With Pacemakers and Implantable Cardioverter Defibrillators
    Cohen, Jennifer D.
    Costa, Heather S.
    Russo, Robert J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (11): : 1631 - 1636
  • [10] How much heating is associated with magnetic resonance imaging in patients with pacemakers and implantable cardioverter defibrillators?
    Steven Mason
    Jon-David Ethington
    Raymond O McCubrey
    Allison E Tonkin
    Jeffrey L Anderson
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)