Meta-Analysis of Transthoracic Echocardiography Versus Cardiac Magnetic Resonance for the Assessment of Aortic Regurgitation After Transcatheter Aortic Valve Implantation

被引:11
|
作者
Papanastasiou, Christos A. [1 ]
Kokkinidis, Damianos G. [2 ]
Jonnalagadda, Anil K. [3 ]
Oikonomou, Evangelos K. [4 ]
Kampaktsis, Polydoros N. [5 ]
Garcia, Mario J. [6 ]
Myerson, Saul G. [7 ]
Karamitsos, Theodoros D. [1 ]
机构
[1] Aristotle Univ Thessaloniki, AHEPA Hosp, Dept Cardiol 1, Thessaloniki, Greece
[2] Albert Einstein Coll Med, Jacobi Med Ctr, Dept Med, Bronx, NY 10467 USA
[3] Washington Hosp Ctr, Medstar, Div Cardiol, Washington, DC 20010 USA
[4] Yale Sch Med, Yale New Haven Hosp, Dept Internal Med, New Haven, CT USA
[5] New York Presbyterian Hosp, Weil Cornell Med Coll, Dept Med, New York, NY USA
[6] Albert Einstein Coll Med, Jacobi Med Ctr, Dept Med, Div Cardiol, Bronx, NY 10467 USA
[7] Univ Oxford, Radcliffe Dept Med, Div Cardiovasc Med, Oxford, England
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2019年 / 124卷 / 08期
关键词
PARAVALVULAR REGURGITATION; QUANTIFICATION; REPLACEMENT; RELIABILITY; SEVERITY; STENOSIS;
D O I
10.1016/j.amjcard.2019.07.036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Residual aortic regurgitation (AR) is a major complication after transcatheter aortic valve implantation (TAVI). Although the echocardiographic assessment of post-TAVI AR remains challenging, cardiac magnetic resonance (CMR) allows direct quantification of AR. The aim of this study was to review the level of agreement between 2-dimensional transthoracic echocardiography (2D TTE) and CMR on grading the severity of AR after TAVI, and determine the accuracy of TTE in detecting moderate or severe AR. Electronic databases were searched in order to identify studies comparing 2D TTE to CMR for post-TAVI AR assessment. Kappa coefficient was used to determine the level of agreement between the 2 imaging modalities. CMR was used as the reference standard in order to assess the diagnostic accuracy of 2D TTE. Seven studies were included in this systematic review. Six studies reported a low correlation between 2D TTE and CMR (kappa coefficient ranging from -0.02 to 0.41), whereas one study showed good agreement with a kappa coefficient of 0.72. Given the heterogeneity in the included studies the diagnostic accuracy of TTE was evaluated by estimating the hierarchical summary receiver operator characteristic curve. The area under the curve for detection of moderate or severe AR with TTE was 0.83 (95% confidence interval 0.79 to 0.86). In conclusion, despite the reported significant disconcordance between TTE and CMR grading of AR, TTE has sufficient ability to discriminate moderate or severe AR from mild or none AR after TAVI in the clinical setting. CMR should be considered when TTE results are equivocal. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:1246 / 1251
页数:6
相关论文
共 50 条
  • [41] Role of the tricuspid regurgitation after mitraclip and transcatheter aortic valve implantation: a systematic review and meta-analysis
    Pavasini, Rita
    Ruggerini, Sara
    Grapsa, Julia
    Biscaglia, Simone
    Tumscitz, Carlo
    Serenelli, Matteo
    Boriani, Giuseppe
    Squeri, Angelo
    Campo, Gianluca
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (06) : 654 - 659
  • [42] Cardiovascular Magnetic Resonance to Evaluate Aortic Regurgitation After Transcatheter Aortic Valve Replacement
    Ribeiro, Henrique B.
    Orwat, Stefan
    Hayek, Salim S.
    Larose, Eric
    Babaliaros, Vasilis
    Dahou, Abdellaziz
    Le Ven, Florent
    Pasian, Sergio
    Puri, Rishi
    Altisent, Omar Abdul-Jawad
    Campelo-Parada, Francisco
    Clavel, Marie-Annick
    Pibarot, Philippe
    Lerakis, Stamatios
    Baumgartner, Helmut
    Rodes-Cabau, Josep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (06) : 577 - 585
  • [43] Transcatheter aortic valve replacement for aortic regurgitation: a systematic review and meta-analysis
    Liu, Ran
    Fu, Zhaolin
    Jiang, Zhengming
    Yan, Yunfeng
    Yao, Jing
    Liu, Xinmin
    Yan, Xiaowei
    Song, Guangyuan
    ESC HEART FAILURE, 2024, 11 (06): : 3488 - 3500
  • [44] Aortic regurgitation after transcatheter aortic valve implantation: mechanisms and implications
    Stahli, Barbara E.
    Maier, Willibald
    Corti, Roberto
    Luscher, Thomas F.
    Jenni, Rolf
    Tanner, Felix C.
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2013, 3 (01) : 15 - 22
  • [45] Prognostic impact of aortic regurgitation after transcatheter aortic valve implantation
    Jilaihawi, Hasan
    Makkar, Raj R.
    EUROINTERVENTION, 2012, 8 : Q31 - Q33
  • [46] Acute Aortic Regurgitation After Transcatheter Aortic Valve Implantation Procedure
    Amien, Bothayna
    Appleby, Clare
    Mills, Joe
    Sandhu, Kully
    Harrington, Deborah
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (12)
  • [47] Treatment and prevention of aortic regurgitation after transcatheter aortic valve implantation
    Hayashida, Kentaro
    Lefevre, Thierry
    EUROINTERVENTION, 2012, 8 : Q34 - Q40
  • [48] Meta-Analysis and Meta-Regression o f Transcatheter Aortic Valve Implantation for Pure Native Aortic Regurgitation
    Takagi, Hisato
    Hari, Yosuke
    Kawai, Norikazu
    Ando, Tomo
    HEART LUNG AND CIRCULATION, 2020, 29 (05): : 729 - 741
  • [49] Multimodality imaging in transcatheter aortic valve implantation: comparison between cardiovascular magnetic resonance, cardiac computed tomography, transesophageal and transthoracic echocardiography
    Andrew Jabbour
    Tevfik F Ismail
    Ali Vazir
    Isabelle Roussin
    Ankur Gulati
    Francisco Alpendurada
    Sameer Zaman
    Oluwatosin Sotubo
    Saman S Zaman
    Ashwin Krishnamoorthy
    Simon Davies
    Sanjay K Prasad
    Susanna Price
    Michael B Rubens
    Neil Moat
    Raad H Mohiaddin
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [50] CARDIAC MRI IN ASSESSMENT OF PARAVALVULAR AORTIC REGURGITATION AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Aman, Wahaj
    Zhan, Yang
    Shah, Dipan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 2996 - 2996