Meta-Analysis of Transthoracic Echocardiography Versus Cardiac Magnetic Resonance for the Assessment of Aortic Regurgitation After Transcatheter Aortic Valve Implantation

被引:11
|
作者
Papanastasiou, Christos A. [1 ]
Kokkinidis, Damianos G. [2 ]
Jonnalagadda, Anil K. [3 ]
Oikonomou, Evangelos K. [4 ]
Kampaktsis, Polydoros N. [5 ]
Garcia, Mario J. [6 ]
Myerson, Saul G. [7 ]
Karamitsos, Theodoros D. [1 ]
机构
[1] Aristotle Univ Thessaloniki, AHEPA Hosp, Dept Cardiol 1, Thessaloniki, Greece
[2] Albert Einstein Coll Med, Jacobi Med Ctr, Dept Med, Bronx, NY 10467 USA
[3] Washington Hosp Ctr, Medstar, Div Cardiol, Washington, DC 20010 USA
[4] Yale Sch Med, Yale New Haven Hosp, Dept Internal Med, New Haven, CT USA
[5] New York Presbyterian Hosp, Weil Cornell Med Coll, Dept Med, New York, NY USA
[6] Albert Einstein Coll Med, Jacobi Med Ctr, Dept Med, Div Cardiol, Bronx, NY 10467 USA
[7] Univ Oxford, Radcliffe Dept Med, Div Cardiovasc Med, Oxford, England
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2019年 / 124卷 / 08期
关键词
PARAVALVULAR REGURGITATION; QUANTIFICATION; REPLACEMENT; RELIABILITY; SEVERITY; STENOSIS;
D O I
10.1016/j.amjcard.2019.07.036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Residual aortic regurgitation (AR) is a major complication after transcatheter aortic valve implantation (TAVI). Although the echocardiographic assessment of post-TAVI AR remains challenging, cardiac magnetic resonance (CMR) allows direct quantification of AR. The aim of this study was to review the level of agreement between 2-dimensional transthoracic echocardiography (2D TTE) and CMR on grading the severity of AR after TAVI, and determine the accuracy of TTE in detecting moderate or severe AR. Electronic databases were searched in order to identify studies comparing 2D TTE to CMR for post-TAVI AR assessment. Kappa coefficient was used to determine the level of agreement between the 2 imaging modalities. CMR was used as the reference standard in order to assess the diagnostic accuracy of 2D TTE. Seven studies were included in this systematic review. Six studies reported a low correlation between 2D TTE and CMR (kappa coefficient ranging from -0.02 to 0.41), whereas one study showed good agreement with a kappa coefficient of 0.72. Given the heterogeneity in the included studies the diagnostic accuracy of TTE was evaluated by estimating the hierarchical summary receiver operator characteristic curve. The area under the curve for detection of moderate or severe AR with TTE was 0.83 (95% confidence interval 0.79 to 0.86). In conclusion, despite the reported significant disconcordance between TTE and CMR grading of AR, TTE has sufficient ability to discriminate moderate or severe AR from mild or none AR after TAVI in the clinical setting. CMR should be considered when TTE results are equivocal. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:1246 / 1251
页数:6
相关论文
共 50 条
  • [1] TRANSTHORACIC ECHOCARDIOGRAPHY VERSUS CARDIAC MAGNETIC RESONANCE FOR THE ASSESSMENT OF AORTIC REGURGITATION AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Jonnalagadda, Anil Kumar
    Papanastasiou, Christos A.
    Kokkinidis, Damianos
    Oikonomou, Evangelos
    Garcia, Mario
    Karamitsos, Theodoros
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1182 - 1182
  • [2] Cardiac Magnetic Resonance Versus Transthoracic Echocardiography for the Assessment and Quantification of Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Implantation
    Ribeiro, Henrique B.
    Le Ven, Florent
    Larose, Eric
    Nombela-Franco, Luis
    Urena, Marina
    Allende, Ricardo
    Amat-Santos, Ignacio J.
    Ricapito, Maria de La Paz
    Thebault, Christophe
    Clavel, Marie-Annick
    Dahou, Abdellaziz
    DeLarochelliere, Robert
    Doyle, Daniel
    Dumont, Eric
    Pibarot, Philippe
    Rodes-Cabau, Josep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B193 - B193
  • [3] Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation
    Ribeiro, Henrique B.
    Le Ven, Florent
    Larose, Eric
    Dahou, Abdellaziz
    Nombela-Franco, Luis
    Urena, Marina
    Allende, Ricardo
    Amat-Santos, Ignacio
    Ricapito, Maria de la Paz
    Thebault, Christophe
    Clavel, Marie-Annick
    Delarochelliere, Robert
    Doyle, Daniel
    Dumont, Eric
    Dumesnil, Jean G.
    Pibarot, Philippe
    Rodes-Cabau, Josep
    HEART, 2014, 100 (24) : 1924 - +
  • [4] AORTIC REGURGITATION AFTER COREVALVE TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI): ASSESSMENT BY ECHOCARDIOGRAPHY AND CARDIOVASCULAR MAGNETIC RESONANCE
    Uddin, A. U.
    Fairbairn, T. A. F.
    Motwani, M. M.
    Kidambi, A. K.
    Steadman, C. S.
    Schlosshan, D. S.
    Blackman, D. B.
    McCann, G. M.
    Plein, S. P.
    Greenwood, J. P. G.
    HEART, 2013, 99
  • [5] ASSESSMENT OF PARAVALVULAR AORTIC REGURGITATION AFTER TRANSCATHETER AORTIC VALVE IMPLANTATION USING CARDIAC MAGNETIC RESONANCE IMAGING: A COMPARATIVE STUDY WITH ECHOCARDIOGRAPHY AND ANGIOGRAPHY
    Bouhzam, Najime
    Caudron, Jerome
    Rodriguez, Carlos
    Durand, Eric
    Tron, Christophe
    Godin, Matthieu
    Bauer, Fabrice
    Cribier, G. Alain
    Dacher, Jean-Nicolas
    Eltchaninoff, Helene
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1997 - A1997
  • [6] Comparison of Two- and Three-Dimensional Transthoracic Echocardiography to Cardiac Magnetic Resonance Imaging for Assessment of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation
    Altiok, Ertunc
    Frick, Michael
    Meyer, Christian G.
    Al Ateah, Ghazi
    Napp, Andreas
    Kirschfink, Annemarie
    Almalla, Mohammad
    Lotfi, Shahran
    Becker, Michael
    Herich, Lena
    Lehmacher, Walter
    Hoffmann, Rainer
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 113 (11): : 1859 - 1866
  • [7] Quantification of paravalvular regurgitation after transcatheter aortic valve implantation by 3D transthoracic echocardiography in comparison with cardiac magnetic resonance imaging
    Altiok, E.
    Frick, M.
    Meyer, C.
    Al Ateah, G.
    Napp, A.
    Almalla, M.
    Aktug, O.
    Becker, M.
    Marx, N.
    Hoffmann, R.
    EUROPEAN HEART JOURNAL, 2013, 34 : 398 - 399
  • [8] Evaluation of aortic regurgitation after transcatheter aortic valve implantation: aortic root angiography in comparison to cardiac magnetic resonance
    Frick, Michael
    Meyer, Christian G.
    Kirschfink, Annemarie
    Altiok, Ertunc
    Lehrke, Michael
    Brehmer, Kathrin
    Lotfi, Shahram
    Hoffmann, Rainer
    EUROINTERVENTION, 2016, 11 (12) : 1419 - 1427
  • [9] Effect of Aortic Regurgitation by Cardiovascular Magnetic Resonance After Transcatheter Aortic Valve Implantation
    Ferreira-Neto, Alfredo N.
    Merten, Constanze
    Beurich, Hans-Wilko
    Zachow, Dirk
    Richardt, Gert
    Larose, Eric
    Guimaraes, Leonardo
    Pibarot, Philippe
    Pelletier-Beaumont, Emilie
    Rodes-Cabau, Josep
    Abdel-Wahab, Mohamed
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (01): : 78 - 84
  • [10] Magnetic resonance flow measurements reveal significant underestimation of aortic regurgitation by echocardiography after transcatheter aortic valve implantation
    Orwat, S.
    Kempny, A.
    Diller, G. P.
    Schuler, P.
    Kaleschke, G.
    Kerckhof, G.
    Bunck, A. C.
    Maintz, D.
    Baumgartner, H.
    EUROPEAN HEART JOURNAL, 2012, 33 : 575 - 575