Improvement of Image Quality in Unenhanced Dual-Layer CT of the Head Using Virtual Monoenergetic Images Compared With Polyenergetic Single-Energy CT

被引:66
|
作者
Neuhaus, Victor [1 ]
Abdullayev, Nuran [1 ]
Hokamp, Nils Grosse [1 ]
Pahn, Gregor [1 ]
Kabbasch, Christoph [1 ]
Mpotsaris, Anastasios [1 ]
Maintz, David [1 ]
Borggrefe, Jan [1 ]
机构
[1] Univ Hosp Cologne, Inst Diagnost & Intervent Radiol, Kerpener Str 62, D-50937 Cologne, Germany
关键词
dual-energy computed tomography; virtual monoenergetic imaging; image contrast and quality; neuroradiology; METAL ARTIFACT REDUCTION; COMPUTED-TOMOGRAPHY; MATERIAL DECOMPOSITION; ANGIOGRAPHY; HEMORRHAGE; ALGORITHM; DIAGNOSIS; STROKE; NECK;
D O I
10.1097/RLI.0000000000000367
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aims of this study were to compare virtual monoenergetic images and polyenergetic images reconstructed from unenhanced dual-layer detector computed tomography (DLCT) of the head and to determine kiloelectron volt levels that optimize image quality, particularly the gray-white matter contrast, and reduce beam hardening artifacts caused by the skull. Materials and Methods: Institutional review board approval was obtained. Forty patients that received DLCT were included in this retrospective study; of these patients, 22 were women and 18 were men. The average age was 61.5 +/- 14.3 years. Virtual monoenergetic images were reconstructed from spectral base images at 40 keV to 120 keV. To calculate signal-to-noise ratio and contrast-to-noise ratio, attenuation and standard deviation of supratentorial gray and white matter were measured in virtual monoenergetic and polyenergetic images. Beam hardening artifacts were detected close to the calvarium and in the posterior fossa. Two radiologists rated the assessment of gray-white matter differentiation and of the subcalvarial space, as well as the artifacts caused by the skull and image noise. Student t test and Wilcoxon test were used to determine significance. Results: Compared with polyenergetic images, superior signal-to-noise ratio and superior contrast-to-noise ratio of gray and white matter were observed in virtual monoenergetic images at low kiloelectron volt levels (P < 0.0001). Subcalvarial artifacts were significantly lower at 120 keV (P < 0.02). Artifacts measured in the posterior fossa were generally lower at high kiloelectron volt levels; however, no statistical significance was detected. Virtual monoenergetic images were rated superior to polyenergetic images in regard to all 4 criteria (P < 0.0001). The observers reported an optimal radiological assessment of gray-whitematter differentiation at 65 keV and optimal assessment of subcalvarial space at 120 keV. Conclusions: In comparison to polyenergetic images, virtual monoenergetic images reconstructed from unenhanced DLCT of the head at 65 keV and 120 keV allow to optimize gray-white matter contrast and reduce beam hardening artifacts caused by the skull, respectively.
引用
收藏
页码:470 / 476
页数:7
相关论文
共 50 条
  • [41] Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT
    Euler, Andre
    Obmann, Markus M.
    Szucs-Farkas, Zsolt
    Mileto, Achille
    Zaehringer, Caroline
    Falkowski, Anna L.
    Winkel, David J.
    Marin, Daniele
    Stieltjes, Bram
    Krauss, Bernhard
    Schindera, Sebastian T.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3405 - 3412
  • [42] Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT
    André Euler
    Markus M. Obmann
    Zsolt Szucs-Farkas
    Achille Mileto
    Caroline Zaehringer
    Anna L. Falkowski
    David J. Winkel
    Daniele Marin
    Bram Stieltjes
    Bernhard Krauss
    Sebastian T. Schindera
    European Radiology, 2018, 28 : 3405 - 3412
  • [43] Generally applicable window settings of low-keV virtual monoenergetic reconstructions in dual-layer CT-angiography of the head and neck
    Zopfs, David
    Lennartz, Simon
    Abdullayev, Nuran
    Lichtenstein, Thorsten
    Laukamp, Kai Roman
    Reimer, Robert Peter
    Kabbasch, Christoph
    Borggrefe, Jan
    Schlamann, Marc
    Neuhaus, Victor
    Hokamp, Nils Grosse
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (08) : 3408 - 3417
  • [44] Determination of the optimal range for virtual monoenergetic images in dual-energy CT based on physical quality parameters
    Fernandez-Velilla Cepria, Enric
    Angel Gonzalez-Ballester, Miguel
    Quera Jordana, Jaume
    Pera, Oscar
    Sanz Latiesas, Xavier
    Foro Arnalot, Palmira
    Membrive Conejo, Ismael
    Rodriguez de Dios, Nuria
    Reig Castillejo, Anna
    Algara Lopez, Manuel
    MEDICAL PHYSICS, 2021, 48 (09) : 5085 - 5095
  • [45] Improvement of Breast Cancer Detection Using Dual-Layer Spectral CT
    Hasse, Felix Christian
    Giannakis, Athanasios
    Wehrse, Eckhard
    Stiller, Wolfram
    Wallwiener, Markus
    Kauczor, Hans-Ulrich
    Weber, Tim F.
    Heil, Jorg
    Mokry, Theresa
    DIAGNOSTICS, 2024, 14 (14)
  • [46] Performance of dual-layer spectrum CT virtual monoenergetic images to assess early rectal adenocarcinoma T-stage: comparison with MR
    Jia, Ziqi
    Guo, Lei
    Yuan, Wenjing
    Dai, Jianhao
    Lu, Jianye
    Li, Zhiqiang
    Du, Xiaohua
    Chen, Weicui
    Liu, Xian
    INSIGHTS INTO IMAGING, 2024, 15 (01)
  • [47] PHYSICALLY MEANINGFUL VIRTUAL UNENHANCED IMAGE RECONSTRUCTION FROM DUAL-ENERGY CT
    Maddah, Mahnaz
    Mendonca, Paulo R. S.
    Bhotika, Rahul
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 808 - 811
  • [48] Comparison of Virtual Unenhanced Images Derived From Dual-Energy CT With True Unenhanced Images in Evaluation of Gallstone Disease
    Lee, Han A.
    Lee, Young Hwan
    Yoon, Kwon-Ha
    Bang, Dong-Ho
    Park, Dong Eun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (01) : 74 - 80
  • [49] Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn’s disease
    Sang Min Lee
    Se Hyung Kim
    Su Joa Ahn
    Hyo-Jin Kang
    Ji Hee Kang
    Joon Koo Han
    European Radiology, 2018, 28 : 2525 - 2534
  • [50] Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn's disease
    Lee, Sang Min
    Kim, Se Hyung
    Ahn, Su Joa
    Kang, Hyo-Jin
    Kang, Ji Hee
    Han, Joon Koo
    EUROPEAN RADIOLOGY, 2018, 28 (06) : 2525 - 2534