Fractionated stereotactic radiotherapy of benign skull-base tumors: a dosimetric comparison of volumetric modulated arc therapy with Rapidarc® versus non-coplanar dynamic arcs

被引:2
|
作者
Martin, Fanny [1 ]
Magnier, Florian [2 ]
Berger, Lucie [2 ]
Miroir, Jessica [1 ]
Chautard, Emmanuel [3 ]
Verrelle, Pierre [1 ,3 ]
Lapeyre, Michel [1 ]
Biau, Julian [1 ,3 ]
机构
[1] Ctr Jean Perrin, Dept Radiotherapy, F-63011 Clermont Ferrand, France
[2] Ctr Jean Perrin, Dept Med Phys, F-63011 Clermont Ferrand, France
[3] Clermont Auvergne Univ, CREaT EA7283, F-63011 Clermont Ferrand, France
来源
RADIATION ONCOLOGY | 2016年 / 11卷
关键词
Benign skull base tumors; Fractionated stereotactic radiotherapy; Novalis; Volumetric modulated arc therapy; Dynamic arc therapy; RADIATION-THERAPY; FRAMELESS RADIOSURGERY; CONFORMAL ARC; STATIC-FIELD; HEARING-LOSS; RAPID ARC; SYSTEM; CANCER; BRAIN; DELIVERY;
D O I
10.1186/s13014-016-0632-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Benign tumors of the skull base are a challenge when delivering radiotherapy. An appropriate choice of radiation technique may significantly improve the patient's outcomes. Our study aimed to compare the dosimetric results of fractionated stereotactic radiotherapy between non-coplanar dynamic arcs and coplanar volumetric modulated arctherapy (Rapidarc (R)). Methods: Thirteen patients treated with Novalis TX (R) were analysed: six vestibular schwannomas, four pituitary adenomas and three meningioma. Two treatment plans were created for each case: dynamic arcs (4-5 non coplanar arcs) and Rapidarc (R) (2 coplanar arcs). All tumors were >3 cm and accessible to both techniques. Patients had a stereotactic facemask (Brainlab) and were daily repositioned by Exactrac (R). GTV and CTV were contoured according to tumor type. A 1-mm margin was added to the CTV to obtain PTV. Radiation doses were 52.2-54 Gy, using 1.8 Gy per fraction. Treatment time was faster with Rapidarc (R). Results: The mean PTV V95 % was 98.8 for Rapidarc (R) and 95.9 % for DA (p = 0.09). Homogeneity index was better with Rapidarc (R) : 0.06 vs. 0.09 (p = 0.01). Higher conformity index values were obtained with Rapidarc (R): 75.2 vs. 67.9 % (p = 0.04). The volume of healthy brain that received a high dose (V90 %) was 0.7 % using Rapidarc (R) vs. 1.4 % with dynamic arcs (p = 0.05). Rapidarc (R) and dynamic arcs gave, respectively, a mean D40 % of 10.5 vs. 18.1 Gy (p = 0.005) for the hippocampus and a Dmean of 25.4 vs. 35.3 Gy (p = 0.008) for the ipsilateral cochlea. Low-dose delivery with Rapidarc (R) and dynamic arcs were, respectively, 184 vs. 166 cm(3) for V20 Gy (p = 0.14) and 1265 vs. 1056 cm(3) for V5 Gy (p = 0.67). Conclusions: Fractionated stereotactic radiotherapy using Rapidarc (R) for large benign tumors of the skull base provided target volume coverage that was at least equal to that of dynamics arcs, with better conformity and homogeneity and faster treatment time. Rapidarc (R) also offered better sparing of the ipsilateral cochlea and hippocampus. Low-dose delivery were similar between both techniques.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Dosimetric Comparison of Automated Non-Coplanar Volumetric-Modulated Arc Therapy and Intensity-Modulated Proton Therapy in Angiosarcoma of the Scalp
    Inui, S.
    Tomita, N.
    Takaoka, T.
    Ueda, Y.
    Ohira, S.
    Tsuchiya, T.
    Miyazaki, M.
    Nishio, T.
    Koizumi, M.
    Konishi, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E675 - E675
  • [12] Chest Wall Dosimetry Using Non-Coplanar Volumetric Modulated Arc Radiotherapy for Lung Stereotactic Ablative Radiotherapy
    Yu, Amy S.
    Maxim, P.
    Gensheimer, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 2963 - 2964
  • [13] Improvement of target coverage using automated non-coplanar volumetric modulated arc therapy planning in stereotactic radiotherapy for cervical metastatic spinal tumors
    Ohira, Shingo
    Ikawa, Toshiki
    Inui, Shoki
    Kanayama, Naoyuki
    Ueda, Yoshihiro
    Miyazaki, Masayoshi
    Nishio, Teiji
    Koizumi, Masahiko
    Konishi, Koji
    MEDICAL DOSIMETRY, 2023, 48 (03) : 197 - 201
  • [14] Is volumetric modulated arc therapy (RapidArc) better than intensity modulated radiotherapy for gynecological malignancies A dosimetric comparison
    Sharma, Manoj Kumar
    Mitra, Swarupa
    Saxena, Upasna
    Bhushan, Manindra
    Shrivastava, Himanshu
    Simson, David K.
    Dewan, Abhinav
    Chauhan, Deepika
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2014, 10 (04) : 883 - 888
  • [15] Stereotactic Body Radiotherapy: Volumetric Modulated Arc Therapy Versus 3D Non-coplanar Conformal Radiotherapy for the Treatment of Early Stage Lung Cancer
    Herbert, C.
    Kwa, W.
    Nakano, S.
    James, K.
    Moiseenko, V.
    Wu, J.
    Schellenberg, D.
    Liu, M.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (06) : 511 - 516
  • [16] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [17] A simplified non-coplanar volumetric modulated arc therapy for the whole brain radiotherapy with hippocampus avoidance
    Xue, Juan
    Jin, Sunian
    Zhang, Hongtao
    Zou, Kun
    Sheng, Junxiu
    Tang, Jinhai
    Zhao, Wanying
    Yang, Ping
    Tang, Lufan
    Lv, Xiupeng
    Lv, Li
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [18] Radiosurgery and Fractionated Radiotherapy for Multiple Cranial Tumors: Comparison between Volumetric Modulated Arc Therapy, Dynamic Arc Therapy and IMRT
    Lee, C.
    Agazaryan, N.
    Selch, M. T.
    De Salles, A. A. F.
    Chow, P. E.
    Tenn, S. E.
    Gorgulho, A.
    Lee, P.
    Steinberg, M. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S791 - S791
  • [19] Dosimetric Comparison of Gamma Knife Extend to Linear Accelerator Base Volumetric Modulated Arc Therapy Plans for Fractionated Stereotactic Radiosurgery
    Phan, J.
    Yang, J. N.
    Ghia, A. J.
    Brown, P. D.
    Garden, A. S.
    Rosenthal, D. I.
    Wang, C.
    Tung, S.
    Luo, D.
    Wang, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E615 - E616
  • [20] A Dosimetric Comparison of Volumetric Modulated Arc Therapy (VMAT) and Non-Coplanar Intensity Modulated Radiation Therapy (IMRT) for Nasal Cavity and Paranasal Sinus Cancer
    Jeong, Y.
    Lee, S.
    Kwak, J.
    Cho, I.
    Yoon, S.
    Kim, J.
    Park, J.
    Choi, E.
    Song, S.
    Kim, Y.
    Kim, S.
    Joo, J.
    Ahn, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S865 - S865