A simplified non-coplanar volumetric modulated arc therapy for the whole brain radiotherapy with hippocampus avoidance

被引:5
|
作者
Xue, Juan [1 ]
Jin, Sunian [1 ]
Zhang, Hongtao [1 ]
Zou, Kun [1 ]
Sheng, Junxiu [1 ]
Tang, Jinhai [1 ]
Zhao, Wanying [1 ]
Yang, Ping [1 ]
Tang, Lufan [1 ]
Lv, Xiupeng [1 ]
Lv, Li [2 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiat Oncol, Dalian, Liaoning, Peoples R China
[2] Dalian Med Univ, Affiliated Hosp 2, Dept Pathol, Dalian, Liaoning, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
关键词
hippocampal avoiding; whole brain radiation therapy; brain metastases; IMRT; VMAT; coplanar; noncoplanar; OF-THE-ART; RADIATION-THERAPY; METASTASES; EPIDEMIOLOGY; IRRADIATION;
D O I
10.3389/fonc.2023.1143564
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeTo evaluate the feasibility of using a simplified non-coplanar volumetric modulated arc therapy (NC-VMAT) and investigate its dosimetric advantages compared with intensity modulated radiation therapy (IMRT) and coplanar volumetric modulated arc therapy (C-VMAT) for hippocampal-avoidance whole brain radiation therapy (HA-WBRT). MethodsTen patients with brain metastase (BM) were included for HA-WBRT. Three treatment plans were generated for each case using IMRT, C-VMAT, and NC-VMAT, respectively. ResultsThe dosimetric results of the three techniques complied roughly with the RTOG 0933 criteria. After dose normalization, the V-30Gy of whole brain planned target volume (WB-PTV) in all the plans was controlled at 95%. Homogeneity index (HI) of WB-PTV was significantly reduced in NC-VMAT (0.249 +/- 0.017) over IMRT (0.265 +/- 0.020, p=0.005) and C-VMAT (0.261 +/- 0.014, p=0.020). In terms of conformity index (CI), NC-VMAT could provide a value of 0.821 +/- 0.010, which was significantly superior to IMRT (0.788 +/- 0.019, p<0.001). According to D-2% of WB-PTV, NC-VMAT could provide a value of 35.62 +/- 0.37Gy, significantly superior to IMRT (36.43 +/- 0.65Gy, p<0.001). According to D-50% of WB-PTV, NC-VMAT can achieve the lowest value of 33.18 +/- 0.29Gy, significantly different from IMRT (33.47 +/- 0.43, p=0.034) and C-VMAT (33.58 +/- 0.37, p=0.006). Regarding D-2%, D-98%, and D-mean of hippocampus, NC-VMAT could control them at 15.57 +/- 0.18Gy, 8.37 +/- 0.26Gy and 11.71 +/- 0.48Gy, respectively. D-2% and D-mean of hippocampus for NC-VMAT was significantly lower than IMRT (D-2%: 16.07 +/- 0.29Gy, p=0.001 D-mean: 12.18 +/- 0.33Gy, p<0.001) and C-VMAT (D-2%: 15.92 +/- 0.37Gy, p=0.009 D-mean: 12.21 +/- 0.54Gy, p<0.001). For other organs-at-risk (OARs), according to D-2% of the right optic nerves and the right lenses, NC-VMAT had the lowest values of 31.86 +/- 1.11Gy and 7.15 +/- 0.31Gy, respectively, which were statistically different from the other two techniques. For other organs including eyes and optic chiasm, NC-VMAT could achieve the lowest doses, different from IMRT statistically. ConclusionThe dosimetry of the three techniques for HA-WBRT could roughly comply with the proposals from RTOG 0933. After dose normalization (D-95%=30Gy), NC-VMAT could significantly improve dose homogeneity and reduce the D-50% in the brain. Besides, it can reduce the D-2% of the hippocampus, optic nerves, and lens. With this approach, an efficient and straightforward plan was accomplished.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Non-coplanar volumetric-modulated arc therapy for craniopharyngiomas reduces doses to hippocampus
    Uto, M.
    Mizowaki, T.
    Ogura, K.
    Hiraoka, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S400 - S400
  • [2] Radiotherapy for unresectable sinonasal cancers: Dosimetric comparison of intensity modulated radiation therapy with coplanar and non-coplanar volumetric modulated arc therapy
    Orlandi, Ester
    Giandini, Tommaso
    Iannacone, Eva
    De Ponti, Elena
    Carrara, Mauro
    Mongioj, Valeria
    Stucchi, Claudio
    Tana, Silvia
    Bossi, Paolo
    Licitra, Lisa
    Fallai, Carlo
    Pignoli, Emanuele
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 113 (02) : 260 - 266
  • [3] Dosimetric comparison among dynamic conformal arc therapy, coplanar and non-coplanar volumetric modulated arc therapy for single brain metastasis
    Torizuka, Daichi
    Uto, Megumi
    Takehana, Keiichi
    Mizowaki, Takashi
    [J]. JOURNAL OF RADIATION RESEARCH, 2021, 62 (06) : 1114 - 1119
  • [4] Dosimetric comparison of coplanar and non-coplanar volumetric-modulated arc therapy in head and neck cancer treated with radiotherapy
    Gayen, Sanjib
    Kombathula, Harsha
    Manna, Sumanta
    Varshney, Sonal
    Pareek, Puneet
    [J]. RADIATION ONCOLOGY JOURNAL, 2020, 38 (02): : 138 - 147
  • [5] Pattern of recurrence of glioblastoma treated with non-coplanar volumetric modulated arc therapy
    Georgiou, I.
    Bhatt, P.
    Bodkin, P.
    Giamouriadis, A.
    Ross, S.
    Walkden, J.
    Olson, S.
    Neelakantan, A.
    Torgersen, A.
    Whibley, M.
    Moleron, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S988 - S988
  • [6] Non-coplanar volumetric-modulated arc therapy (VMAT) for craniopharyngiomas reduces radiation doses to the bilateral hippocampus: a planning study comparing dynamic conformal arc therapy, coplanar VMAT, and non-coplanar VMAT
    Uto, Megumi
    Mizowaki, Takashi
    Ogura, Kengo
    Hiraoka, Masahiro
    [J]. RADIATION ONCOLOGY, 2016, 11
  • [7] Dosimetric Comparison of Coplanar Volumetric Modulated Arc Therapy and Non-coplanar Intensity Modulated Radiation Therapy for Pancreatic Cancer
    Badkul, R. K.
    Kile, L.
    Saleh, H.
    Chen, A. M.
    Lominska, C. E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E635 - E636
  • [8] Non-coplanar volumetric-modulated arc therapy (VMAT) for craniopharyngiomas reduces radiation doses to the bilateral hippocampus: a planning study comparing dynamic conformal arc therapy, coplanar VMAT, and non-coplanar VMAT
    Megumi Uto
    Takashi Mizowaki
    Kengo Ogura
    Masahiro Hiraoka
    [J]. Radiation Oncology, 11
  • [9] Assessment of different head tilt angles in volumetric modulated arc therapy for hippocampus-avoidance whole-brain radiotherapy
    Yuan, Cuiyun
    Xu, Sisi
    Li, Yang
    Quan, Enzhuo
    Chen, Dongjie
    Liang, Jun
    Liu, Chenbin
    [J]. FRONTIERS IN ONCOLOGY, 2024, 14
  • [10] Automated Non-coplanar Volumetric Modulated Arc Therapy Planning for Maxillary Sinus Carcinoma
    Ohira, Shingo
    Inui, Shoki
    Kanayama, Naoyuki
    Ueda, Yoshihiro
    Miyazaki, Masayoshi
    Koizumi, Masahiko
    Konishi, Koji
    [J]. IN VIVO, 2023, 37 (01): : 417 - 423