A simplified non-coplanar volumetric modulated arc therapy for the whole brain radiotherapy with hippocampus avoidance

被引:5
|
作者
Xue, Juan [1 ]
Jin, Sunian [1 ]
Zhang, Hongtao [1 ]
Zou, Kun [1 ]
Sheng, Junxiu [1 ]
Tang, Jinhai [1 ]
Zhao, Wanying [1 ]
Yang, Ping [1 ]
Tang, Lufan [1 ]
Lv, Xiupeng [1 ]
Lv, Li [2 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiat Oncol, Dalian, Liaoning, Peoples R China
[2] Dalian Med Univ, Affiliated Hosp 2, Dept Pathol, Dalian, Liaoning, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
关键词
hippocampal avoiding; whole brain radiation therapy; brain metastases; IMRT; VMAT; coplanar; noncoplanar; OF-THE-ART; RADIATION-THERAPY; METASTASES; EPIDEMIOLOGY; IRRADIATION;
D O I
10.3389/fonc.2023.1143564
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeTo evaluate the feasibility of using a simplified non-coplanar volumetric modulated arc therapy (NC-VMAT) and investigate its dosimetric advantages compared with intensity modulated radiation therapy (IMRT) and coplanar volumetric modulated arc therapy (C-VMAT) for hippocampal-avoidance whole brain radiation therapy (HA-WBRT). MethodsTen patients with brain metastase (BM) were included for HA-WBRT. Three treatment plans were generated for each case using IMRT, C-VMAT, and NC-VMAT, respectively. ResultsThe dosimetric results of the three techniques complied roughly with the RTOG 0933 criteria. After dose normalization, the V-30Gy of whole brain planned target volume (WB-PTV) in all the plans was controlled at 95%. Homogeneity index (HI) of WB-PTV was significantly reduced in NC-VMAT (0.249 +/- 0.017) over IMRT (0.265 +/- 0.020, p=0.005) and C-VMAT (0.261 +/- 0.014, p=0.020). In terms of conformity index (CI), NC-VMAT could provide a value of 0.821 +/- 0.010, which was significantly superior to IMRT (0.788 +/- 0.019, p<0.001). According to D-2% of WB-PTV, NC-VMAT could provide a value of 35.62 +/- 0.37Gy, significantly superior to IMRT (36.43 +/- 0.65Gy, p<0.001). According to D-50% of WB-PTV, NC-VMAT can achieve the lowest value of 33.18 +/- 0.29Gy, significantly different from IMRT (33.47 +/- 0.43, p=0.034) and C-VMAT (33.58 +/- 0.37, p=0.006). Regarding D-2%, D-98%, and D-mean of hippocampus, NC-VMAT could control them at 15.57 +/- 0.18Gy, 8.37 +/- 0.26Gy and 11.71 +/- 0.48Gy, respectively. D-2% and D-mean of hippocampus for NC-VMAT was significantly lower than IMRT (D-2%: 16.07 +/- 0.29Gy, p=0.001 D-mean: 12.18 +/- 0.33Gy, p<0.001) and C-VMAT (D-2%: 15.92 +/- 0.37Gy, p=0.009 D-mean: 12.21 +/- 0.54Gy, p<0.001). For other organs-at-risk (OARs), according to D-2% of the right optic nerves and the right lenses, NC-VMAT had the lowest values of 31.86 +/- 1.11Gy and 7.15 +/- 0.31Gy, respectively, which were statistically different from the other two techniques. For other organs including eyes and optic chiasm, NC-VMAT could achieve the lowest doses, different from IMRT statistically. ConclusionThe dosimetry of the three techniques for HA-WBRT could roughly comply with the proposals from RTOG 0933. After dose normalization (D-95%=30Gy), NC-VMAT could significantly improve dose homogeneity and reduce the D-50% in the brain. Besides, it can reduce the D-2% of the hippocampus, optic nerves, and lens. With this approach, an efficient and straightforward plan was accomplished.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Whole brain radiotherapy with hippocampal avoidance and simultaneous integrated boost for brain metastases: a dosimetric volumetric-modulated arc therapy study
    Niccolò Giaj Levra
    Gianluisa Sicignano
    Alba Fiorentino
    Sergio Fersino
    Francesco Ricchetti
    Rosario Mazzola
    Stefania Naccarato
    Ruggero Ruggieri
    Filippo Alongi
    [J]. La radiologia medica, 2016, 121 : 60 - 69
  • [32] Improvement of target coverage using automated non-coplanar volumetric modulated arc therapy planning in stereotactic radiotherapy for cervical metastatic spinal tumors
    Ohira, Shingo
    Ikawa, Toshiki
    Inui, Shoki
    Kanayama, Naoyuki
    Ueda, Yoshihiro
    Miyazaki, Masayoshi
    Nishio, Teiji
    Koizumi, Masahiko
    Konishi, Koji
    [J]. MEDICAL DOSIMETRY, 2023, 48 (03) : 197 - 201
  • [33] Whole brain radiotherapy with hippocampal avoidance and simultaneous integrated boost for brain metastases: a dosimetric volumetric-modulated arc therapy study
    Levra, Niccolo Giaj
    Sicignano, Gianluisa
    Fiorentino, Alba
    Fersino, Sergio
    Ricchetti, Francesco
    Mazzola, Rosario
    Naccarato, Stefania
    Ruggieri, Ruggero
    Alongi, Filippo
    [J]. RADIOLOGIA MEDICA, 2016, 121 (01): : 60 - 69
  • [34] Sparing the hippocampus and the hypothalamic- pituitary region during whole brain radiotherapy: a volumetric modulated arc therapy planning study
    P. Mehta
    S. Janssen
    F. B. Fahlbusch
    S. M. Schmid
    J. Gebauer
    F. Cremers
    C. Ziemann
    M. Tartz
    D. Rades
    [J]. BMC Cancer, 20
  • [35] Sparing the hippocampus and the hypothalamic- pituitary region during whole brain radiotherapy: a volumetric modulated arc therapy planning study
    Mehta, P.
    Janssen, S.
    Fahlbusch, F. B.
    Schmid, S. M.
    Gebauer, J.
    Cremers, F.
    Ziemann, C.
    Tartz, M.
    Rades, D.
    [J]. BMC CANCER, 2020, 20 (01)
  • [36] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [37] Monitoring of mechanical errors and their dosimetric impact throughout the course of non-coplanar continuous volumetric-modulated arc therapy
    Hirashima, Hideaki
    Nakamura, Mitsuhiro
    Miyabe, Yuki
    Uto, Megumi
    Nakamura, Kiyonao
    Mizowaki, Takashi
    [J]. RADIATION ONCOLOGY, 2018, 13
  • [38] Clinical Feasibility of Using Single-isocentre Non-coplanar Volumetric Modulated Arc Therapy Combined with Non-coplanar Cone Beam Computed Tomography in Hypofractionated Stereotactic Radiotherapy for Five or Fewer Multiple Intracranial Metastases
    Lai, J. L.
    Liu, S. P.
    Liu, J.
    Li, X. K.
    Chen, J.
    Jia, Y. M.
    Lei, K. J.
    Zhou, L.
    [J]. CLINICAL ONCOLOGY, 2023, 35 (06) : 408 - 416
  • [39] Monitoring of mechanical errors and their dosimetric impact throughout the course of non-coplanar continuous volumetric-modulated arc therapy
    Hideaki Hirashima
    Mitsuhiro Nakamura
    Yuki Miyabe
    Megumi Uto
    Kiyonao Nakamura
    Takashi Mizowaki
    [J]. Radiation Oncology, 13
  • [40] Optimization of collimator angles in dual-arc volumetric modulated arc therapy planning for whole-brain radiotherapy with hippocampus and inner ear sparing
    Sun, Wuji
    Chen, Kunzhi
    Li, Yu
    Xia, Wenming
    Dong, Lihua
    Shi, Yinghua
    Ge, Chao
    Yang, Xu
    Wang, Libo
    Wang, Huidong
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)