A Novel Grading Scale for the Angiographic Assessment of Intracranial Aneurysms Treated Using Flow Diverting Stents

被引:377
|
作者
O'Kelly, C. J. [1 ]
Krings, T. [2 ]
Fiorella, D. [3 ]
Marotta, T. R. [2 ]
机构
[1] Univ Alberta, Dept Surg, Div Neurosurg, Edmonton, AB, Canada
[2] Univ Toronto, Dept Radiol, Toronto, ON M5S 1A1, Canada
[3] Stony Brook Univ Med Ctr, Dept Neurol Surg, Stony Brook, NY USA
来源
INTERVENTIONAL NEURORADIOLOGY | 2010年 / 16卷 / 02期
关键词
intracranial aneurysm; stent; grading scale; PIPELINE EMBOLIZATION DEVICE; RECONSTRUCTION;
D O I
10.1177/159101991001600204
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Flow diverting stents are emerging as a treatment option for difficult intracranial aneurysms. Current grading scales for assessment of angiographic outcomes following aneurysm treatment do not apply to aneurysms treated by flow diversion. We propose a novel grading scale based on the degree of angiographic filling and contrast stasis. This scale will facilitate communication and standardize reporting of outcomes following flow diversion treatments.
引用
收藏
页码:133 / 137
页数:5
相关论文
共 50 条
  • [21] Use of flow-diverting stents in visceral aneurysms
    Gomez Jabalera, E.
    Dilme Munoz, J.
    Villalba Aunon, J.
    Soto Carricas, B.
    Escudero, J. R.
    ANGIOLOGIA, 2015, 67 (01): : 56 - 57
  • [22] Flow-diverting stents for the treatment of arterial aneurysms
    Sfyroeras, George S.
    Dalainas, Ilias
    Giannakopoulos, Triantafyllos G.
    Antonopoulos, Konstantinos
    Kakisis, John D.
    Liapis, Christos D.
    JOURNAL OF VASCULAR SURGERY, 2012, 56 (03) : 839 - 846
  • [23] A Study on the Efficacy and Safety of Pipeline Shield Stents and Nonmodified Surface Flow-Diverting Stents in Patients with Intracranial Aneurysms
    Garcia-Nunez, Julio
    Vera, Daniela D.
    Ortiz, Andres F.
    Rodriguez, Adriana
    Lara, Juan Jose
    Gomez, Maria Jose
    Serrano-Gomez, Sergio
    Reyes, Adriana
    Ferreira-Prada, Carlos
    Galvis-Mendez, Melquizidel
    Vargas-Perez, Oliverio
    Mantilla-Garcia, Daniel E.
    WORLD NEUROSURGERY, 2024, 183 : E781 - E786
  • [24] Cerebral Aneurysms Treated with Flow-Diverting Stents: Computational Models with Intravascular Blood Flow Measurements
    Levitt, M. R.
    McGah, P. M.
    Aliseda, A.
    Mourad, P. D.
    Nerva, J. D.
    Vaidya, S. S.
    Morton, R. P.
    Ghodke, B. V.
    Kim, L. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (01) : 143 - 148
  • [25] Small Unruptured Intracranial Aneurysms Can Be Effectively Treated With Flow-Diverting Devices
    Li, Li
    Gao, Bu-Lang
    Shao, Qiu-Ji
    Zhang, Guang-Lin
    Wang, Zi-Liang
    Li, Tian-Xiao
    Zhu, Liang-Fu
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [26] Actual Metal Coverage at the Neck Is Critical for Flow-Diverting Stents in Treating Intracranial Aneurysms REPLY
    van den Berg, R.
    Schneiders, J. J.
    Ferns, S. P.
    Majoie, C. B.
    Vanbavel, E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (03) : E33 - E33
  • [27] SILK Flow-Diverting Device for Intracranial Aneurysms
    Binning, Mandy J.
    Natarajan, Sabareesh K.
    Bulsara, Ketan R.
    Siddiqui, Adnan H.
    Hopkins, L. Nelson
    Levy, Elad I.
    WORLD NEUROSURGERY, 2011, 76 (05) : 477.e1 - 477.e6
  • [28] Treatment of unruptured aneurysms with flow diverting stents is safe and effective
    Bendszus, Martin
    Moehlenbruch, Markus A.
    EUROPEAN STROKE JOURNAL, 2023, 8 (02) : 600 - 601
  • [29] Flow-Diverting Stents for Intracranial Bifurcation Aneurysm Treatment
    Saleme, Suzana
    Iosif, Christina
    Ponomarjova, Sanita
    Mendes, George
    Camilleri, Yann
    Caire, Francois
    Boncoeur, Marie-Paule
    Mounayer, Charbel
    NEUROSURGERY, 2014, 75 (06) : 623 - 631
  • [30] Continuum model for flow diverting stents in 3D patient-specific simulation of intracranial aneurysms
    Li, Sha
    Chopard, Bastien
    Latt, Jonas
    JOURNAL OF COMPUTATIONAL SCIENCE, 2019, 38