A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration

被引:212
|
作者
Schazmann, Benjamin [1 ]
Morris, Deirdre [2 ]
Slater, Collor [2 ]
Beirne, Stephen [2 ]
Fay, Cormac [2 ]
Reuveny, Ronen [3 ]
Moyna, Niall [3 ]
Diamond, Dermot [2 ]
机构
[1] Dublin Inst Technol, Sch Chem & Pharmaceut Sci, Dublin 8, Ireland
[2] Dublin City Univ, NCSR, Dublin 9, Ireland
[3] Dublin City Univ, Sch Hlth & Human Performance, Dublin 9, Ireland
基金
爱尔兰科学基金会;
关键词
ION-SELECTIVE ELECTRODES; POLYMERIC MEMBRANE ELECTRODES; CYSTIC-FIBROSIS; SOLID-CONTACT; FLUID REPLACEMENT; EXERCISE; CHLORIDE; WATER; ELECTROLYTES; CALIXARENES;
D O I
10.1039/b9ay00184k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a new method for the real-time quantitative analysis of sodium in human sweat, consolidating sweat collection and analysis in a single, integrated, wearable platform. This temporal data opens up new possibilities in the study of human physiology, broadly applicable from assessing high performance athletes to monitoring Cystic Fibrosis (CF) sufferers. Our compact Sodium Sensor Belt (SSB) consists of a sodium selective Ion Selective Electrode (ISE) integrated into a platform that can be interfaced with the human body during exercise. No skin cleaning regime or sweat storage technology is required as the sweat is continually wicked from the skin to a sensing surface and from there to a storage area via a fabric pump. Our results suggest that after an initial equilibration period, a steady-state sodium plateau concentration was reached. Atomic Absorption Spectroscopy (AAS) was used as a reference method, and this has confirmed the accuracy of the new continuous monitoring approach. The steady-state concentrations observed were found to fall within ranges previously found in the literature, which further validates the approach. Daily calibration repeatability (n = 4) was +/- 3.0% RSD and over a three month period reproducibility was +/- 12.1% RSD (n = 56). As a further application, we attempted to monitor the sweat of Cystic Fibrosis (CF) sufferers using the same device. We observed high sodium concentrations symptomatic of CF (similar to 60 mM Na(+)) for two CF patients, with no conclusive results for the remaining patients due to their limited exercising capability, and high viscosity/low volume of sweat produced.
引用
收藏
页码:342 / 348
页数:7
相关论文
共 50 条
  • [41] A NOVEL WEARABLE SWEAT RATE SENSOR FOR BOTH DOMINANT AND RECESSIVE SWEAT RATE MEASUREMENT
    Gao, Kunpeng
    Wang, Xiaolin
    Yang, Bing
    Chen, Xiang
    Li, Xiuyan
    Liu, Jinquan
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 817 - 820
  • [42] Real-time Measurement Of Cell Concentration During Bioprinting
    Matavosian, A. A.
    Matthews, J.
    Bonassar, L. J.
    TISSUE ENGINEERING PART A, 2022, 28 : 130 - 131
  • [43] Real-time Measurement of Liquid Concentration by Digital Holography
    Sun, Chan
    Wang, Zhe
    Cui, Yutong
    Jiang, Zhuqing
    HOLOGRAPHY, DIFFRACTIVE OPTICS, AND APPLICATIONS VII, 2017, 10022
  • [44] An Improved Chronoamperometry for Electrochemical Real-time PCR Measurement
    Chen, Xuhai
    Du, Min
    ADVANCES IN CHEMICAL ENGINEERING, PTS 1-3, 2012, 396-398 : 110 - +
  • [45] A Biomimetic, Biocompatible OECT Sensor for the Real-Time Measurement of Concentration and Saturation of Ions in Plant Sap
    Gentile, Francesco
    Vurro, Filippo
    Janni, Michela
    Manfredi, Riccardo
    Cellini, Francesco
    Petrozza, Angelo
    Zappettini, Andrea
    Coppede, Nicola
    ADVANCED ELECTRONIC MATERIALS, 2022, 8 (10)
  • [46] Thread-based multiplexed sensor patch for real-time sweat monitoring
    Terse-Thakoor, Trupti
    Punjiya, Meera
    Matharu, Zimple
    Lyu, Boyang
    Ahmad, Meraj
    Giles, Grace E.
    Owyeung, Rachel
    Alaimo, Francesco
    Shojaei Baghini, Maryam
    Brunye, Tad T.
    Sonkusale, Sameer
    NPJ FLEXIBLE ELECTRONICS, 2020, 4 (01)
  • [47] Toward the development of a wearable optical respiratory sensor for real-time use
    Chavez-Gaxiola A.
    Fisher Z.
    La Belle J.T.
    Critical Reviews in Biomedical Engineering, 2019, 47 (02): : 131 - 139
  • [48] A Wearable Respiration Sensor for Real-Time Monitoring of Chronic Kidney Disease
    Wang, Chao
    Cai, Yiyu
    Zhou, Wei
    Chen, Peng
    Xu, Li
    Han, Tao
    Hu, Yulin
    Xu, Xuhui
    Liu, Bitao
    Yu, Xue
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (10) : 12630 - 12639
  • [49] Real-Time Noninvasive Measurement of Glucose Concentration Using a Modified Hilbert Shaped Microwave Sensor
    Odabashyan, Levon
    Babajanyan, Arsen
    Baghdasaryan, Zhirayr
    Kim, Seungwan
    Kim, Jongchel
    Friedman, Barry
    Lee, Jung-Ha
    Lee, Kiejin
    SENSORS, 2019, 19 (24)
  • [50] Development of a Wearable Sensor Glove for Real-Time Sign Language Translation
    Ambar R.
    Salim S.
    Wahab M.H.A.
    Jamil M.M.A.
    Phing T.C.
    Annals of Emerging Technologies in Computing, 2023, 7 (05) : 25 - 38